Cargando…

Digital Tomosynthesis for Evaluating Metastatic Lung Nodules: Nodule Visibility, Learning Curves, and Reading Times

OBJECTIVE: To evaluate nodule visibility, learning curves, and reading times for digital tomosynthesis (DT). MATERIALS AND METHODS: We included 80 patients who underwent computed tomography (CT) and DT before pulmonary metastasectomy. One experienced chest radiologist annotated all visible nodules o...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Kyung Hee, Goo, Jin Mo, Lee, Sang Min, Park, Chang Min, Bahn, Young Eun, Kim, Hyungjin, Song, Yong Sub, Hwang, Eui Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Radiology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4347279/
https://www.ncbi.nlm.nih.gov/pubmed/25741205
http://dx.doi.org/10.3348/kjr.2015.16.2.430
Descripción
Sumario:OBJECTIVE: To evaluate nodule visibility, learning curves, and reading times for digital tomosynthesis (DT). MATERIALS AND METHODS: We included 80 patients who underwent computed tomography (CT) and DT before pulmonary metastasectomy. One experienced chest radiologist annotated all visible nodules on thin-section CT scans using computer-aided detection software. Two radiologists used CT as the reference standard and retrospectively graded the visibility of nodules on DT. Nodule detection performance was evaluated in four sessions of 20 cases each by six readers. After each session, readers were unblinded to the DT images by revealing the true-positive markings and were instructed to self-analyze their own misreads. Receiver-operating-characteristic curves were determined. RESULTS: Among 414 nodules on CT, 53.3% (221/414) were visible on DT. The main reason for not seeing a nodule on DT was small size (93.3%, ≤ 5 mm). DT revealed a substantial number of malignant nodules (84.1%, 143/170). The proportion of malignant nodules among visible nodules on DT was significantly higher (64.7%, 143/221) than that on CT (41.1%, 170/414) (p < 0.001). Area under the curve (AUC) values at the initial session were > 0.8, and the average detection rate for malignant nodules was 85% (210/246). The inter-session analysis of the AUC showed no significant differences among the readers, and the detection rate for malignant nodules did not differ across sessions. A slight improvement in reading times was observed. CONCLUSION: Most malignant nodules > 5 mm were visible on DT. As nodule detection performance was high from the initial session, DT may be readily applicable for radiology residents and board-certified radiologists.