Cargando…

Fluorescence detection of tramadol in healthy Chinese volunteers by high-performance liquid chromatography and bioequivalence assessment

This study developed a revised high-performance liquid chromatography fluorescence method to determine plasma tramadol concentration, and thereby to examine the bioequivalence of two tramadol formulations among healthy male Chinese volunteers. The study used a double-blind, randomized, 2×2 crossover...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhou, Xiao, Liu, Ji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4348049/
https://www.ncbi.nlm.nih.gov/pubmed/25750519
http://dx.doi.org/10.2147/DDDT.S73723
_version_ 1782359883345035264
author Zhou, Xiao
Liu, Ji
author_facet Zhou, Xiao
Liu, Ji
author_sort Zhou, Xiao
collection PubMed
description This study developed a revised high-performance liquid chromatography fluorescence method to determine plasma tramadol concentration, and thereby to examine the bioequivalence of two tramadol formulations among healthy male Chinese volunteers. The study used a double-blind, randomized, 2×2 crossover-design principle. Calculated pharmacokinetic parameters for both formulations were consistent with previous reports. According to the observation of vital signs and laboratory measurement, no subjects had any adverse reactions. The geometric mean ratios (90% confidence interval) of the test drug/reference drug for tramadol were 100.2% (95.3%–103.4%) for the area under the plasma concentration–time curve (AUC) from time zero to the last measurable concentration, 99.6% (94.2%–102.7%) for the AUC from administration to infinite time, and 100.8% (93.1%–106.4%) for maximum concentration. For the 90% confidence intervals of the test/reference AUC ratio and maximum concentration ratio of tramadol, both were in the acceptance range for bioequivalence. According to the two preparations by pharmacokinetic parameter statistics, the half-life, mean residence time, and clearance values showed no significant statistical differences. Therefore, the conclusion of this study was that the two tramadol formulations (tablets and capsules) were bioequivalent.
format Online
Article
Text
id pubmed-4348049
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-43480492015-03-06 Fluorescence detection of tramadol in healthy Chinese volunteers by high-performance liquid chromatography and bioequivalence assessment Zhou, Xiao Liu, Ji Drug Des Devel Ther Original Research This study developed a revised high-performance liquid chromatography fluorescence method to determine plasma tramadol concentration, and thereby to examine the bioequivalence of two tramadol formulations among healthy male Chinese volunteers. The study used a double-blind, randomized, 2×2 crossover-design principle. Calculated pharmacokinetic parameters for both formulations were consistent with previous reports. According to the observation of vital signs and laboratory measurement, no subjects had any adverse reactions. The geometric mean ratios (90% confidence interval) of the test drug/reference drug for tramadol were 100.2% (95.3%–103.4%) for the area under the plasma concentration–time curve (AUC) from time zero to the last measurable concentration, 99.6% (94.2%–102.7%) for the AUC from administration to infinite time, and 100.8% (93.1%–106.4%) for maximum concentration. For the 90% confidence intervals of the test/reference AUC ratio and maximum concentration ratio of tramadol, both were in the acceptance range for bioequivalence. According to the two preparations by pharmacokinetic parameter statistics, the half-life, mean residence time, and clearance values showed no significant statistical differences. Therefore, the conclusion of this study was that the two tramadol formulations (tablets and capsules) were bioequivalent. Dove Medical Press 2015-02-26 /pmc/articles/PMC4348049/ /pubmed/25750519 http://dx.doi.org/10.2147/DDDT.S73723 Text en © 2015 Zhou and Liu. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Zhou, Xiao
Liu, Ji
Fluorescence detection of tramadol in healthy Chinese volunteers by high-performance liquid chromatography and bioequivalence assessment
title Fluorescence detection of tramadol in healthy Chinese volunteers by high-performance liquid chromatography and bioequivalence assessment
title_full Fluorescence detection of tramadol in healthy Chinese volunteers by high-performance liquid chromatography and bioequivalence assessment
title_fullStr Fluorescence detection of tramadol in healthy Chinese volunteers by high-performance liquid chromatography and bioequivalence assessment
title_full_unstemmed Fluorescence detection of tramadol in healthy Chinese volunteers by high-performance liquid chromatography and bioequivalence assessment
title_short Fluorescence detection of tramadol in healthy Chinese volunteers by high-performance liquid chromatography and bioequivalence assessment
title_sort fluorescence detection of tramadol in healthy chinese volunteers by high-performance liquid chromatography and bioequivalence assessment
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4348049/
https://www.ncbi.nlm.nih.gov/pubmed/25750519
http://dx.doi.org/10.2147/DDDT.S73723
work_keys_str_mv AT zhouxiao fluorescencedetectionoftramadolinhealthychinesevolunteersbyhighperformanceliquidchromatographyandbioequivalenceassessment
AT liuji fluorescencedetectionoftramadolinhealthychinesevolunteersbyhighperformanceliquidchromatographyandbioequivalenceassessment