Cargando…

Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty

BACKGROUND: The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae(®) Dual M...

Descripción completa

Detalles Bibliográficos
Autores principales: Mohammed, Riazuddin, Hayward, Keith, Mulay, Sanjay, Bindi, Frank, Wallace, Murray
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4348500/
https://www.ncbi.nlm.nih.gov/pubmed/25330736
http://dx.doi.org/10.1007/s10195-014-0324-9
_version_ 1782359931297464320
author Mohammed, Riazuddin
Hayward, Keith
Mulay, Sanjay
Bindi, Frank
Wallace, Murray
author_facet Mohammed, Riazuddin
Hayward, Keith
Mulay, Sanjay
Bindi, Frank
Wallace, Murray
author_sort Mohammed, Riazuddin
collection PubMed
description BACKGROUND: The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae(®) Dual Mobility Acetabular cup (Orthodynamics Ltd, Gloucestershire, UK) to address the problem of instability in primary and revision total hip arthroplasty (THA). MATERIALS AND METHODS: A retrospective review was carried out of all hip arthroplasties performed in a District General Hospital utilising the dual-mobility socket from January 2007 to December 2012. Clinical and radiological outcomes were analysed for 44 hips in 41 patients, comprising 20 primary and 24 revision THA. The average age of the study group was 70.8 years (range 56–84 years) for primary and 76.4 years (range 56–89 years) for revision arthroplasty. Among the primary THA, always performed for hip osteoarthritis or in presence of osteoarthritic changes, the reasons to choose a dual mobility cup were central nervous system problems such as Parkinson’s disease, stroke, dementia (10), hip fracture (5), failed hip fracture fixation (2), severe fixed hip deformity (2) and diffuse peripheral neuropathy (1). The indications for revisions were recurrent dislocation (17), aseptic loosening with abductor deficiency (4), failed hemiarthroplasty with abductor deficiency (2) and neglected dislocation (1). RESULTS: At a mean follow-up of 22 months (range 6–63 months), none of the hips had any dislocation, instability or infection and no further surgical intervention was required. Radiological assessment showed that one uncemented socket in a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new position. The patient did not have complications from this and did not need any surgical intervention. CONCLUSIONS: Even though postoperative hip stability depends on several factors other than design-related ones, our study shows promising early results for reducing the risk of instability in this challenging group of patients undergoing primary and revision hip arthroplasty. LEVEL OF EVIDENCE: IV.
format Online
Article
Text
id pubmed-4348500
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-43485002015-03-11 Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty Mohammed, Riazuddin Hayward, Keith Mulay, Sanjay Bindi, Frank Wallace, Murray J Orthop Traumatol Original Article BACKGROUND: The concept of a dual-mobility hip socket involves the standard femoral head component encased in a larger polyethylene liner, which in turn articulates inside a metal shell implanted in the native acetabulum. The aim of this study was to assess outcomes from using a Serf Novae(®) Dual Mobility Acetabular cup (Orthodynamics Ltd, Gloucestershire, UK) to address the problem of instability in primary and revision total hip arthroplasty (THA). MATERIALS AND METHODS: A retrospective review was carried out of all hip arthroplasties performed in a District General Hospital utilising the dual-mobility socket from January 2007 to December 2012. Clinical and radiological outcomes were analysed for 44 hips in 41 patients, comprising 20 primary and 24 revision THA. The average age of the study group was 70.8 years (range 56–84 years) for primary and 76.4 years (range 56–89 years) for revision arthroplasty. Among the primary THA, always performed for hip osteoarthritis or in presence of osteoarthritic changes, the reasons to choose a dual mobility cup were central nervous system problems such as Parkinson’s disease, stroke, dementia (10), hip fracture (5), failed hip fracture fixation (2), severe fixed hip deformity (2) and diffuse peripheral neuropathy (1). The indications for revisions were recurrent dislocation (17), aseptic loosening with abductor deficiency (4), failed hemiarthroplasty with abductor deficiency (2) and neglected dislocation (1). RESULTS: At a mean follow-up of 22 months (range 6–63 months), none of the hips had any dislocation, instability or infection and no further surgical intervention was required. Radiological assessment showed that one uncemented socket in a revision arthroplasty performed for recurrent dislocation had changed position, but was stable in the new position. The patient did not have complications from this and did not need any surgical intervention. CONCLUSIONS: Even though postoperative hip stability depends on several factors other than design-related ones, our study shows promising early results for reducing the risk of instability in this challenging group of patients undergoing primary and revision hip arthroplasty. LEVEL OF EVIDENCE: IV. Springer International Publishing 2014-10-21 2015-03 /pmc/articles/PMC4348500/ /pubmed/25330736 http://dx.doi.org/10.1007/s10195-014-0324-9 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Original Article
Mohammed, Riazuddin
Hayward, Keith
Mulay, Sanjay
Bindi, Frank
Wallace, Murray
Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty
title Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty
title_full Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty
title_fullStr Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty
title_full_unstemmed Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty
title_short Outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty
title_sort outcomes of dual-mobility acetabular cup for instability in primary and revision total hip arthroplasty
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4348500/
https://www.ncbi.nlm.nih.gov/pubmed/25330736
http://dx.doi.org/10.1007/s10195-014-0324-9
work_keys_str_mv AT mohammedriazuddin outcomesofdualmobilityacetabularcupforinstabilityinprimaryandrevisiontotalhiparthroplasty
AT haywardkeith outcomesofdualmobilityacetabularcupforinstabilityinprimaryandrevisiontotalhiparthroplasty
AT mulaysanjay outcomesofdualmobilityacetabularcupforinstabilityinprimaryandrevisiontotalhiparthroplasty
AT bindifrank outcomesofdualmobilityacetabularcupforinstabilityinprimaryandrevisiontotalhiparthroplasty
AT wallacemurray outcomesofdualmobilityacetabularcupforinstabilityinprimaryandrevisiontotalhiparthroplasty