Cargando…

Influence of Intraaortic Balloon Pump Counterpulsation on Transesophageal Echocardiography Derived Determinants of Diastolic Function

INTRODUCTION: Intraaortic balloon pump counterpulsation (IABP) is often used in patients with acute coronary syndrome for its favourable effects on left ventricular (LV) systolic function and coronary perfusion. However, the effects of IABP on LV diastolic function have not been comprehensively inve...

Descripción completa

Detalles Bibliográficos
Autores principales: Nowak-Machen, Martina, Hilberath, Jan N., Rosenberger, Peter, Schmid, Eckhard, Memtsoudis, Stavros G., Angermair, Johannes, Tuli, Jayshree K., Shernan, Stanton K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4349649/
https://www.ncbi.nlm.nih.gov/pubmed/25739068
http://dx.doi.org/10.1371/journal.pone.0118788
_version_ 1782360056226906112
author Nowak-Machen, Martina
Hilberath, Jan N.
Rosenberger, Peter
Schmid, Eckhard
Memtsoudis, Stavros G.
Angermair, Johannes
Tuli, Jayshree K.
Shernan, Stanton K.
author_facet Nowak-Machen, Martina
Hilberath, Jan N.
Rosenberger, Peter
Schmid, Eckhard
Memtsoudis, Stavros G.
Angermair, Johannes
Tuli, Jayshree K.
Shernan, Stanton K.
author_sort Nowak-Machen, Martina
collection PubMed
description INTRODUCTION: Intraaortic balloon pump counterpulsation (IABP) is often used in patients with acute coronary syndrome for its favourable effects on left ventricular (LV) systolic function and coronary perfusion. However, the effects of IABP on LV diastolic function have not been comprehensively investigated. Acute diastolic dysfunction has been linked to increased morbidity and mortality. The aim of this study was to examine the influence of IABP on LV diastolic dysfunction using standard TEE derived parameters. METHODS: Intraoperative TEE was performed in 10 patients (mean age 65 ± 11 yrs) undergoing urgent coronary artery bypass graft surgery (CABG), who had received an IABP preoperatively. TEE derived measures of diastolic dysfunction included early to late transmitral Doppler inflow velocity ratio (E/A), deceleration time (Dt), pulmonary venous systolic to diastolic Doppler velocity ratio (S/D), transmitral propagation velocity (Vp), and the ratio of early to late mitral annular tissue Doppler velocities (e’/a’). Statistical analyses included the Wilcoxon Sign-Rank test, and a p<0.05 was considered significant. RESULTS: Transmitral inflow E/A ratios increased significantly from 0.86 to 1.07 (p < 0.05), while Dt decreased significantly from 218 to 180 ms (p < 0.05) with the use of IABP. Significant increases in Vp (34 cm/s to 43 cm/s; p < 0.05), and e’/a’ (0.58 to 0.71; p < 0.05) suggested a favourable influence of intraaortic counterpulsation on diastolic function. CONCLUSION: The use of perioperative IABP significantly improves TEE derived parameters of diastolic function consistent with a favourable impact on LV relaxation in cardiac surgery patients undergoing CABG.
format Online
Article
Text
id pubmed-4349649
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-43496492015-03-17 Influence of Intraaortic Balloon Pump Counterpulsation on Transesophageal Echocardiography Derived Determinants of Diastolic Function Nowak-Machen, Martina Hilberath, Jan N. Rosenberger, Peter Schmid, Eckhard Memtsoudis, Stavros G. Angermair, Johannes Tuli, Jayshree K. Shernan, Stanton K. PLoS One Research Article INTRODUCTION: Intraaortic balloon pump counterpulsation (IABP) is often used in patients with acute coronary syndrome for its favourable effects on left ventricular (LV) systolic function and coronary perfusion. However, the effects of IABP on LV diastolic function have not been comprehensively investigated. Acute diastolic dysfunction has been linked to increased morbidity and mortality. The aim of this study was to examine the influence of IABP on LV diastolic dysfunction using standard TEE derived parameters. METHODS: Intraoperative TEE was performed in 10 patients (mean age 65 ± 11 yrs) undergoing urgent coronary artery bypass graft surgery (CABG), who had received an IABP preoperatively. TEE derived measures of diastolic dysfunction included early to late transmitral Doppler inflow velocity ratio (E/A), deceleration time (Dt), pulmonary venous systolic to diastolic Doppler velocity ratio (S/D), transmitral propagation velocity (Vp), and the ratio of early to late mitral annular tissue Doppler velocities (e’/a’). Statistical analyses included the Wilcoxon Sign-Rank test, and a p<0.05 was considered significant. RESULTS: Transmitral inflow E/A ratios increased significantly from 0.86 to 1.07 (p < 0.05), while Dt decreased significantly from 218 to 180 ms (p < 0.05) with the use of IABP. Significant increases in Vp (34 cm/s to 43 cm/s; p < 0.05), and e’/a’ (0.58 to 0.71; p < 0.05) suggested a favourable influence of intraaortic counterpulsation on diastolic function. CONCLUSION: The use of perioperative IABP significantly improves TEE derived parameters of diastolic function consistent with a favourable impact on LV relaxation in cardiac surgery patients undergoing CABG. Public Library of Science 2015-03-04 /pmc/articles/PMC4349649/ /pubmed/25739068 http://dx.doi.org/10.1371/journal.pone.0118788 Text en © 2015 Nowak-Machen et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Nowak-Machen, Martina
Hilberath, Jan N.
Rosenberger, Peter
Schmid, Eckhard
Memtsoudis, Stavros G.
Angermair, Johannes
Tuli, Jayshree K.
Shernan, Stanton K.
Influence of Intraaortic Balloon Pump Counterpulsation on Transesophageal Echocardiography Derived Determinants of Diastolic Function
title Influence of Intraaortic Balloon Pump Counterpulsation on Transesophageal Echocardiography Derived Determinants of Diastolic Function
title_full Influence of Intraaortic Balloon Pump Counterpulsation on Transesophageal Echocardiography Derived Determinants of Diastolic Function
title_fullStr Influence of Intraaortic Balloon Pump Counterpulsation on Transesophageal Echocardiography Derived Determinants of Diastolic Function
title_full_unstemmed Influence of Intraaortic Balloon Pump Counterpulsation on Transesophageal Echocardiography Derived Determinants of Diastolic Function
title_short Influence of Intraaortic Balloon Pump Counterpulsation on Transesophageal Echocardiography Derived Determinants of Diastolic Function
title_sort influence of intraaortic balloon pump counterpulsation on transesophageal echocardiography derived determinants of diastolic function
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4349649/
https://www.ncbi.nlm.nih.gov/pubmed/25739068
http://dx.doi.org/10.1371/journal.pone.0118788
work_keys_str_mv AT nowakmachenmartina influenceofintraaorticballoonpumpcounterpulsationontransesophagealechocardiographyderiveddeterminantsofdiastolicfunction
AT hilberathjann influenceofintraaorticballoonpumpcounterpulsationontransesophagealechocardiographyderiveddeterminantsofdiastolicfunction
AT rosenbergerpeter influenceofintraaorticballoonpumpcounterpulsationontransesophagealechocardiographyderiveddeterminantsofdiastolicfunction
AT schmideckhard influenceofintraaorticballoonpumpcounterpulsationontransesophagealechocardiographyderiveddeterminantsofdiastolicfunction
AT memtsoudisstavrosg influenceofintraaorticballoonpumpcounterpulsationontransesophagealechocardiographyderiveddeterminantsofdiastolicfunction
AT angermairjohannes influenceofintraaorticballoonpumpcounterpulsationontransesophagealechocardiographyderiveddeterminantsofdiastolicfunction
AT tulijayshreek influenceofintraaorticballoonpumpcounterpulsationontransesophagealechocardiographyderiveddeterminantsofdiastolicfunction
AT shernanstantonk influenceofintraaorticballoonpumpcounterpulsationontransesophagealechocardiographyderiveddeterminantsofdiastolicfunction