Cargando…

Measurement of real pulsatile blood flow using X-ray PIV technique with CO(2) microbubbles

Synchrotron X-ray imaging technique has been used to investigate biofluid flows in a non-destructive manner. This study aims to investigate the feasibility of the X-ray PIV technique with CO(2) microbubbles as flow tracer for measurement of pulsatile blood flows under in vivo conditions. The traceab...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Hanwook, Yeom, Eunseop, Seo, Seung-Jun, Lim, Jae-Hong, Lee, Sang-Joon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4351547/
https://www.ncbi.nlm.nih.gov/pubmed/25744850
http://dx.doi.org/10.1038/srep08840
_version_ 1782360338891538432
author Park, Hanwook
Yeom, Eunseop
Seo, Seung-Jun
Lim, Jae-Hong
Lee, Sang-Joon
author_facet Park, Hanwook
Yeom, Eunseop
Seo, Seung-Jun
Lim, Jae-Hong
Lee, Sang-Joon
author_sort Park, Hanwook
collection PubMed
description Synchrotron X-ray imaging technique has been used to investigate biofluid flows in a non-destructive manner. This study aims to investigate the feasibility of the X-ray PIV technique with CO(2) microbubbles as flow tracer for measurement of pulsatile blood flows under in vivo conditions. The traceability of CO(2) microbubbles in a pulsatile flow was demonstrated through in vitro experiment. A rat extracorporeal bypass loop was used by connecting a tube between the abdominal aorta and jugular vein of a rat to obtain hemodynamic information of actual pulsatile blood flows without changing the hemorheological properties. The decrease in image contrast of the surrounding tissue was also investigated for in vivo applications of the proposed technique. This technique could be used to accurately measure whole velocity field information of real pulsatile blood flows and has strong potential for hemodynamic diagnosis of cardiovascular diseases.
format Online
Article
Text
id pubmed-4351547
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-43515472015-03-10 Measurement of real pulsatile blood flow using X-ray PIV technique with CO(2) microbubbles Park, Hanwook Yeom, Eunseop Seo, Seung-Jun Lim, Jae-Hong Lee, Sang-Joon Sci Rep Article Synchrotron X-ray imaging technique has been used to investigate biofluid flows in a non-destructive manner. This study aims to investigate the feasibility of the X-ray PIV technique with CO(2) microbubbles as flow tracer for measurement of pulsatile blood flows under in vivo conditions. The traceability of CO(2) microbubbles in a pulsatile flow was demonstrated through in vitro experiment. A rat extracorporeal bypass loop was used by connecting a tube between the abdominal aorta and jugular vein of a rat to obtain hemodynamic information of actual pulsatile blood flows without changing the hemorheological properties. The decrease in image contrast of the surrounding tissue was also investigated for in vivo applications of the proposed technique. This technique could be used to accurately measure whole velocity field information of real pulsatile blood flows and has strong potential for hemodynamic diagnosis of cardiovascular diseases. Nature Publishing Group 2015-03-06 /pmc/articles/PMC4351547/ /pubmed/25744850 http://dx.doi.org/10.1038/srep08840 Text en Copyright © 2015, Macmillan Publishers Limited. All rights reserved http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article's Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder in order to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Park, Hanwook
Yeom, Eunseop
Seo, Seung-Jun
Lim, Jae-Hong
Lee, Sang-Joon
Measurement of real pulsatile blood flow using X-ray PIV technique with CO(2) microbubbles
title Measurement of real pulsatile blood flow using X-ray PIV technique with CO(2) microbubbles
title_full Measurement of real pulsatile blood flow using X-ray PIV technique with CO(2) microbubbles
title_fullStr Measurement of real pulsatile blood flow using X-ray PIV technique with CO(2) microbubbles
title_full_unstemmed Measurement of real pulsatile blood flow using X-ray PIV technique with CO(2) microbubbles
title_short Measurement of real pulsatile blood flow using X-ray PIV technique with CO(2) microbubbles
title_sort measurement of real pulsatile blood flow using x-ray piv technique with co(2) microbubbles
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4351547/
https://www.ncbi.nlm.nih.gov/pubmed/25744850
http://dx.doi.org/10.1038/srep08840
work_keys_str_mv AT parkhanwook measurementofrealpulsatilebloodflowusingxraypivtechniquewithco2microbubbles
AT yeomeunseop measurementofrealpulsatilebloodflowusingxraypivtechniquewithco2microbubbles
AT seoseungjun measurementofrealpulsatilebloodflowusingxraypivtechniquewithco2microbubbles
AT limjaehong measurementofrealpulsatilebloodflowusingxraypivtechniquewithco2microbubbles
AT leesangjoon measurementofrealpulsatilebloodflowusingxraypivtechniquewithco2microbubbles