Cargando…
Case report on successful ‘bail out’ aortic homograft implantation in a 81-year old woman with aortic ring rupture after double TAVI procedure
A 81-year woman was admitted to our institution due to worsening chronic heart failure. The patient presented herself with severe aortic valve stenosis and mitral valve insufficiency. Due to estimated high operative risk a TAVI approach was chosen. Following the fist TAVI implantation (Sapien XT™ 26...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4351833/ https://www.ncbi.nlm.nih.gov/pubmed/25887519 http://dx.doi.org/10.1186/s13019-015-0233-x |
_version_ | 1782360365957382144 |
---|---|
author | Kołsut, Piotr Juraszek, Andrzej Brzozowski, Piotr Dąbrowski, Maciej Witkowski, Adam Różański, Jacek Kuśmierczyk, Mariusz |
author_facet | Kołsut, Piotr Juraszek, Andrzej Brzozowski, Piotr Dąbrowski, Maciej Witkowski, Adam Różański, Jacek Kuśmierczyk, Mariusz |
author_sort | Kołsut, Piotr |
collection | PubMed |
description | A 81-year woman was admitted to our institution due to worsening chronic heart failure. The patient presented herself with severe aortic valve stenosis and mitral valve insufficiency. Due to estimated high operative risk a TAVI approach was chosen. Following the fist TAVI implantation (Sapien XT™ 26 mm) a big paravalvular leakage was diagnosed. Hence, in order to close the paravalular leakage, a second TAVI procedure with a Core Valve™ 26 mm was performed. A following CT scan showed signs of aortic ring rupture. We therefore decided to perform open heart surgery. After removal of both TAVI prosthesis, native valve excision a 21 mm sized aortic homograft was implanted. Additionally, a mitral valve annuloplasty with CE Physio™ 28 mm ring was performed. In the postoperative period the patient remained for three weeks in the ICU, followed by two weeks on general ward. The patient was discharged home in good condition, with good left ventricular function and regular homograft function in the aortic position. The open heart surgery should have had been performed primarily. Nevertheless, the decision on the treatment strategy is always difficult in case of borderline patients. |
format | Online Article Text |
id | pubmed-4351833 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-43518332015-03-07 Case report on successful ‘bail out’ aortic homograft implantation in a 81-year old woman with aortic ring rupture after double TAVI procedure Kołsut, Piotr Juraszek, Andrzej Brzozowski, Piotr Dąbrowski, Maciej Witkowski, Adam Różański, Jacek Kuśmierczyk, Mariusz J Cardiothorac Surg Case Report A 81-year woman was admitted to our institution due to worsening chronic heart failure. The patient presented herself with severe aortic valve stenosis and mitral valve insufficiency. Due to estimated high operative risk a TAVI approach was chosen. Following the fist TAVI implantation (Sapien XT™ 26 mm) a big paravalvular leakage was diagnosed. Hence, in order to close the paravalular leakage, a second TAVI procedure with a Core Valve™ 26 mm was performed. A following CT scan showed signs of aortic ring rupture. We therefore decided to perform open heart surgery. After removal of both TAVI prosthesis, native valve excision a 21 mm sized aortic homograft was implanted. Additionally, a mitral valve annuloplasty with CE Physio™ 28 mm ring was performed. In the postoperative period the patient remained for three weeks in the ICU, followed by two weeks on general ward. The patient was discharged home in good condition, with good left ventricular function and regular homograft function in the aortic position. The open heart surgery should have had been performed primarily. Nevertheless, the decision on the treatment strategy is always difficult in case of borderline patients. BioMed Central 2015-03-04 /pmc/articles/PMC4351833/ /pubmed/25887519 http://dx.doi.org/10.1186/s13019-015-0233-x Text en © Kolsut et al.; licensee BioMed Central. 2015 This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Case Report Kołsut, Piotr Juraszek, Andrzej Brzozowski, Piotr Dąbrowski, Maciej Witkowski, Adam Różański, Jacek Kuśmierczyk, Mariusz Case report on successful ‘bail out’ aortic homograft implantation in a 81-year old woman with aortic ring rupture after double TAVI procedure |
title | Case report on successful ‘bail out’ aortic homograft implantation in a 81-year old woman with aortic ring rupture after double TAVI procedure |
title_full | Case report on successful ‘bail out’ aortic homograft implantation in a 81-year old woman with aortic ring rupture after double TAVI procedure |
title_fullStr | Case report on successful ‘bail out’ aortic homograft implantation in a 81-year old woman with aortic ring rupture after double TAVI procedure |
title_full_unstemmed | Case report on successful ‘bail out’ aortic homograft implantation in a 81-year old woman with aortic ring rupture after double TAVI procedure |
title_short | Case report on successful ‘bail out’ aortic homograft implantation in a 81-year old woman with aortic ring rupture after double TAVI procedure |
title_sort | case report on successful ‘bail out’ aortic homograft implantation in a 81-year old woman with aortic ring rupture after double tavi procedure |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4351833/ https://www.ncbi.nlm.nih.gov/pubmed/25887519 http://dx.doi.org/10.1186/s13019-015-0233-x |
work_keys_str_mv | AT kołsutpiotr casereportonsuccessfulbailoutaortichomograftimplantationina81yearoldwomanwithaorticringruptureafterdoubletaviprocedure AT juraszekandrzej casereportonsuccessfulbailoutaortichomograftimplantationina81yearoldwomanwithaorticringruptureafterdoubletaviprocedure AT brzozowskipiotr casereportonsuccessfulbailoutaortichomograftimplantationina81yearoldwomanwithaorticringruptureafterdoubletaviprocedure AT dabrowskimaciej casereportonsuccessfulbailoutaortichomograftimplantationina81yearoldwomanwithaorticringruptureafterdoubletaviprocedure AT witkowskiadam casereportonsuccessfulbailoutaortichomograftimplantationina81yearoldwomanwithaorticringruptureafterdoubletaviprocedure AT rozanskijacek casereportonsuccessfulbailoutaortichomograftimplantationina81yearoldwomanwithaorticringruptureafterdoubletaviprocedure AT kusmierczykmariusz casereportonsuccessfulbailoutaortichomograftimplantationina81yearoldwomanwithaorticringruptureafterdoubletaviprocedure |