Cargando…
Repeatability of Quantitative Sodium Magnetic Resonance Imaging for Estimating Pseudo-Intracellular Sodium Concentration and Pseudo-Extracellular Volume Fraction in Brain at 3 T
The purpose of this study is to assess the repeatability of the quantification of pseudo-intracellular sodium concentration (C(1)) and pseudo-extracellular volume fraction (α) estimated in brain in vivo using sodium magnetic resonance (MRI) at 3 T. Eleven healthy subjects were scanned twice, with tw...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4353709/ https://www.ncbi.nlm.nih.gov/pubmed/25751272 http://dx.doi.org/10.1371/journal.pone.0118692 |
_version_ | 1782360631456825344 |
---|---|
author | Madelin, Guillaume Babb, James Xia, Ding Regatte, Ravinder R. |
author_facet | Madelin, Guillaume Babb, James Xia, Ding Regatte, Ravinder R. |
author_sort | Madelin, Guillaume |
collection | PubMed |
description | The purpose of this study is to assess the repeatability of the quantification of pseudo-intracellular sodium concentration (C(1)) and pseudo-extracellular volume fraction (α) estimated in brain in vivo using sodium magnetic resonance (MRI) at 3 T. Eleven healthy subjects were scanned twice, with two sodium MRI acquisitions (with and without fluid suppression by inversion recovery), and two double inversion recovery (DIR) proton MRI. DIR MRIs were used to create masks of gray and white matter (GM, WM), that were subsequently applied to the C(1) and α maps calculated from sodium MRI and a tissue three-compartment model, in order to measure the distributions of these two parameters in GM, WM or full brain (GM+WM) separately. The mean, median, mode, standard deviation (std), skewness and kurtosis of the C(1) and α distributions in whole GM, WM and full brain were calculated for each subject, averaged over all data, and used as parameters for the repeatability assessment. The coefficient of variation (CV) was calculated as a measure of reliability for the detection of intra-subject changes in C(1) and αfor each parameter, while intraclass correlation (ICC) was used as a measure of repeatability. It was found that the CV of most of the parameters was around 10–20% (except for C(1) kurtosis which is about 40%) for C(1) and α measurements, and that ICC was moderate to very good (0.4 to 0.9) for C(1) parameters and for some of the α parameters (mainly skewness and kurtosis). In conclusion, the proposed method could allow to reliably detect changes of 50% and above of the different measurement parameters of C(1) and αin neuropathologies (multiple sclerosis, tumor, stroke, Alzheimer’s disease) compared to healthy subjects, and that skewness and kurtosis of the distributions of C(1) and αseem to be the more sensitive parameters to these changes. |
format | Online Article Text |
id | pubmed-4353709 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-43537092015-03-17 Repeatability of Quantitative Sodium Magnetic Resonance Imaging for Estimating Pseudo-Intracellular Sodium Concentration and Pseudo-Extracellular Volume Fraction in Brain at 3 T Madelin, Guillaume Babb, James Xia, Ding Regatte, Ravinder R. PLoS One Research Article The purpose of this study is to assess the repeatability of the quantification of pseudo-intracellular sodium concentration (C(1)) and pseudo-extracellular volume fraction (α) estimated in brain in vivo using sodium magnetic resonance (MRI) at 3 T. Eleven healthy subjects were scanned twice, with two sodium MRI acquisitions (with and without fluid suppression by inversion recovery), and two double inversion recovery (DIR) proton MRI. DIR MRIs were used to create masks of gray and white matter (GM, WM), that were subsequently applied to the C(1) and α maps calculated from sodium MRI and a tissue three-compartment model, in order to measure the distributions of these two parameters in GM, WM or full brain (GM+WM) separately. The mean, median, mode, standard deviation (std), skewness and kurtosis of the C(1) and α distributions in whole GM, WM and full brain were calculated for each subject, averaged over all data, and used as parameters for the repeatability assessment. The coefficient of variation (CV) was calculated as a measure of reliability for the detection of intra-subject changes in C(1) and αfor each parameter, while intraclass correlation (ICC) was used as a measure of repeatability. It was found that the CV of most of the parameters was around 10–20% (except for C(1) kurtosis which is about 40%) for C(1) and α measurements, and that ICC was moderate to very good (0.4 to 0.9) for C(1) parameters and for some of the α parameters (mainly skewness and kurtosis). In conclusion, the proposed method could allow to reliably detect changes of 50% and above of the different measurement parameters of C(1) and αin neuropathologies (multiple sclerosis, tumor, stroke, Alzheimer’s disease) compared to healthy subjects, and that skewness and kurtosis of the distributions of C(1) and αseem to be the more sensitive parameters to these changes. Public Library of Science 2015-03-09 /pmc/articles/PMC4353709/ /pubmed/25751272 http://dx.doi.org/10.1371/journal.pone.0118692 Text en © 2015 Madelin et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Madelin, Guillaume Babb, James Xia, Ding Regatte, Ravinder R. Repeatability of Quantitative Sodium Magnetic Resonance Imaging for Estimating Pseudo-Intracellular Sodium Concentration and Pseudo-Extracellular Volume Fraction in Brain at 3 T |
title | Repeatability of Quantitative Sodium Magnetic Resonance Imaging for Estimating Pseudo-Intracellular Sodium Concentration and Pseudo-Extracellular Volume Fraction in Brain at 3 T |
title_full | Repeatability of Quantitative Sodium Magnetic Resonance Imaging for Estimating Pseudo-Intracellular Sodium Concentration and Pseudo-Extracellular Volume Fraction in Brain at 3 T |
title_fullStr | Repeatability of Quantitative Sodium Magnetic Resonance Imaging for Estimating Pseudo-Intracellular Sodium Concentration and Pseudo-Extracellular Volume Fraction in Brain at 3 T |
title_full_unstemmed | Repeatability of Quantitative Sodium Magnetic Resonance Imaging for Estimating Pseudo-Intracellular Sodium Concentration and Pseudo-Extracellular Volume Fraction in Brain at 3 T |
title_short | Repeatability of Quantitative Sodium Magnetic Resonance Imaging for Estimating Pseudo-Intracellular Sodium Concentration and Pseudo-Extracellular Volume Fraction in Brain at 3 T |
title_sort | repeatability of quantitative sodium magnetic resonance imaging for estimating pseudo-intracellular sodium concentration and pseudo-extracellular volume fraction in brain at 3 t |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4353709/ https://www.ncbi.nlm.nih.gov/pubmed/25751272 http://dx.doi.org/10.1371/journal.pone.0118692 |
work_keys_str_mv | AT madelinguillaume repeatabilityofquantitativesodiummagneticresonanceimagingforestimatingpseudointracellularsodiumconcentrationandpseudoextracellularvolumefractioninbrainat3t AT babbjames repeatabilityofquantitativesodiummagneticresonanceimagingforestimatingpseudointracellularsodiumconcentrationandpseudoextracellularvolumefractioninbrainat3t AT xiading repeatabilityofquantitativesodiummagneticresonanceimagingforestimatingpseudointracellularsodiumconcentrationandpseudoextracellularvolumefractioninbrainat3t AT regatteravinderr repeatabilityofquantitativesodiummagneticresonanceimagingforestimatingpseudointracellularsodiumconcentrationandpseudoextracellularvolumefractioninbrainat3t |