Precision of Corneal Thickness Measurements Obtained Using the Scheimpflug-Placido Imaging and Agreement with Ultrasound Pachymetry

Purpose. To assess the reliability and comparability of measuring central corneal thickness (CCT) and thinnest corneal thickness (TCT) using a new Scheimpflug-Placido analyzer (TMS-5, Japan) and ultrasound (US) pachymetry. Methods. Seventy-six healthy subjects were prospectively measured 3 times by...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Jinhai, Savini, Giacomo, Wang, Chengfang, Lu, Weicong, Gao, Rongrong, Li, Yuanguang, Wang, Qinmei, Zhao, Yune
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4355121/
https://www.ncbi.nlm.nih.gov/pubmed/25810919
http://dx.doi.org/10.1155/2015/328798
_version_ 1782360823839064064
author Huang, Jinhai
Savini, Giacomo
Wang, Chengfang
Lu, Weicong
Gao, Rongrong
Li, Yuanguang
Wang, Qinmei
Zhao, Yune
author_facet Huang, Jinhai
Savini, Giacomo
Wang, Chengfang
Lu, Weicong
Gao, Rongrong
Li, Yuanguang
Wang, Qinmei
Zhao, Yune
author_sort Huang, Jinhai
collection PubMed
description Purpose. To assess the reliability and comparability of measuring central corneal thickness (CCT) and thinnest corneal thickness (TCT) using a new Scheimpflug-Placido analyzer (TMS-5, Japan) and ultrasound (US) pachymetry. Methods. Seventy-six healthy subjects were prospectively measured 3 times by 1 operator using the TMS-5, 3 additional consecutive scans were performed by a second operator, and ultrasound (US) pachymetry measurements were taken. The test-retest repeatability (TRT), coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were calculated to evaluate intraoperator repeatability and interoperator reproducibility. Agreement among the devices was assessed using Bland-Altman plots and 95% limits of agreement (LoA). Results. The intraoperators TRT and CoV were <19 μm and 2.0%, respectively. The interoperators TRT and CoV were <12 μm and 1.0%, respectively, and ICC was >0.90. The mean CCT and TCT measurements using the TMS-5 were 15.97 μm (95% LoA from −26.42 to −5.52 μm) and 20.32 μm (95% LoA from −30.67 to −9.97 μm) smaller, respectively, than those using US pachymetry. Conclusions. The TMS-5 shows good repeatability and reproducibility for measuring CCT and TCT in normal subjects but only moderate agreement with US pachymetry results. Caution is warranted before using these techniques interchangeably.
format Online
Article
Text
id pubmed-4355121
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-43551212015-03-25 Precision of Corneal Thickness Measurements Obtained Using the Scheimpflug-Placido Imaging and Agreement with Ultrasound Pachymetry Huang, Jinhai Savini, Giacomo Wang, Chengfang Lu, Weicong Gao, Rongrong Li, Yuanguang Wang, Qinmei Zhao, Yune J Ophthalmol Research Article Purpose. To assess the reliability and comparability of measuring central corneal thickness (CCT) and thinnest corneal thickness (TCT) using a new Scheimpflug-Placido analyzer (TMS-5, Japan) and ultrasound (US) pachymetry. Methods. Seventy-six healthy subjects were prospectively measured 3 times by 1 operator using the TMS-5, 3 additional consecutive scans were performed by a second operator, and ultrasound (US) pachymetry measurements were taken. The test-retest repeatability (TRT), coefficient of variation (CoV), and intraclass correlation coefficient (ICC) were calculated to evaluate intraoperator repeatability and interoperator reproducibility. Agreement among the devices was assessed using Bland-Altman plots and 95% limits of agreement (LoA). Results. The intraoperators TRT and CoV were <19 μm and 2.0%, respectively. The interoperators TRT and CoV were <12 μm and 1.0%, respectively, and ICC was >0.90. The mean CCT and TCT measurements using the TMS-5 were 15.97 μm (95% LoA from −26.42 to −5.52 μm) and 20.32 μm (95% LoA from −30.67 to −9.97 μm) smaller, respectively, than those using US pachymetry. Conclusions. The TMS-5 shows good repeatability and reproducibility for measuring CCT and TCT in normal subjects but only moderate agreement with US pachymetry results. Caution is warranted before using these techniques interchangeably. Hindawi Publishing Corporation 2015 2015-02-24 /pmc/articles/PMC4355121/ /pubmed/25810919 http://dx.doi.org/10.1155/2015/328798 Text en Copyright © 2015 Jinhai Huang et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Huang, Jinhai
Savini, Giacomo
Wang, Chengfang
Lu, Weicong
Gao, Rongrong
Li, Yuanguang
Wang, Qinmei
Zhao, Yune
Precision of Corneal Thickness Measurements Obtained Using the Scheimpflug-Placido Imaging and Agreement with Ultrasound Pachymetry
title Precision of Corneal Thickness Measurements Obtained Using the Scheimpflug-Placido Imaging and Agreement with Ultrasound Pachymetry
title_full Precision of Corneal Thickness Measurements Obtained Using the Scheimpflug-Placido Imaging and Agreement with Ultrasound Pachymetry
title_fullStr Precision of Corneal Thickness Measurements Obtained Using the Scheimpflug-Placido Imaging and Agreement with Ultrasound Pachymetry
title_full_unstemmed Precision of Corneal Thickness Measurements Obtained Using the Scheimpflug-Placido Imaging and Agreement with Ultrasound Pachymetry
title_short Precision of Corneal Thickness Measurements Obtained Using the Scheimpflug-Placido Imaging and Agreement with Ultrasound Pachymetry
title_sort precision of corneal thickness measurements obtained using the scheimpflug-placido imaging and agreement with ultrasound pachymetry
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4355121/
https://www.ncbi.nlm.nih.gov/pubmed/25810919
http://dx.doi.org/10.1155/2015/328798
work_keys_str_mv AT huangjinhai precisionofcornealthicknessmeasurementsobtainedusingthescheimpflugplacidoimagingandagreementwithultrasoundpachymetry
AT savinigiacomo precisionofcornealthicknessmeasurementsobtainedusingthescheimpflugplacidoimagingandagreementwithultrasoundpachymetry
AT wangchengfang precisionofcornealthicknessmeasurementsobtainedusingthescheimpflugplacidoimagingandagreementwithultrasoundpachymetry
AT luweicong precisionofcornealthicknessmeasurementsobtainedusingthescheimpflugplacidoimagingandagreementwithultrasoundpachymetry
AT gaorongrong precisionofcornealthicknessmeasurementsobtainedusingthescheimpflugplacidoimagingandagreementwithultrasoundpachymetry
AT liyuanguang precisionofcornealthicknessmeasurementsobtainedusingthescheimpflugplacidoimagingandagreementwithultrasoundpachymetry
AT wangqinmei precisionofcornealthicknessmeasurementsobtainedusingthescheimpflugplacidoimagingandagreementwithultrasoundpachymetry
AT zhaoyune precisionofcornealthicknessmeasurementsobtainedusingthescheimpflugplacidoimagingandagreementwithultrasoundpachymetry