Cargando…

Bioresorbable scaffolds for percutaneous coronary interventions

Innovations in drug-eluting stents (DES) have substantially reduced rates of in-segment restenosis and early stent thrombosis, improving clinical outcomes following percutaneous coronary interventions (PCI). However a fixed metallic implant in a vessel wall with restored patency and residual disease...

Descripción completa

Detalles Bibliográficos
Autor principal: Gogas, Bill D.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bloomsbury Qatar Foundation Journals 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4355515/
https://www.ncbi.nlm.nih.gov/pubmed/25780795
http://dx.doi.org/10.5339/gcsp.2014.55
_version_ 1782360871200096256
author Gogas, Bill D.
author_facet Gogas, Bill D.
author_sort Gogas, Bill D.
collection PubMed
description Innovations in drug-eluting stents (DES) have substantially reduced rates of in-segment restenosis and early stent thrombosis, improving clinical outcomes following percutaneous coronary interventions (PCI). However a fixed metallic implant in a vessel wall with restored patency and residual disease remains a precipitating factor for sustained local inflammation, in-stent neo-atherosclerosis and impaired vasomotor function increasing the risk for late complications attributed to late or very late stent thrombosis and late target lesion revascularization (TLR) (late catch-up). The quest for optimal coronary stenting continues by further innovations in stent design and by using biocompatible materials other than cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding, local drug-elution and future restoration of vessel anatomy, physiology and local hemodynamics have been recently developed. These devices have been utilized in selected clinical applications so far providing preliminary evidence of safety showing comparable performance with current generation drug-eluting stents (DES). Herein we provide a comprehensive overview of the current status of these technologies, we elaborate on the potential benefits of transient coronary scaffolds over permanent stents in the context of vascular reparation therapy, and we further focus on the evolving challenges these devices have to overcome to compete with current generation DES. Condensed Abstract:: The quest for optimizing percutaneous coronary interventions continues by iterative innovations in device materials beyond cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding; local drug-elution and future restoration of vessel anatomy, physiology and local hemodynamics were recently developed. These devices have been utilized in selected clinical applications providing preliminary evidence of safety showing comparable intermediate term clinical outcomes with current generation drug-eluting stents.
format Online
Article
Text
id pubmed-4355515
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Bloomsbury Qatar Foundation Journals
record_format MEDLINE/PubMed
spelling pubmed-43555152015-03-16 Bioresorbable scaffolds for percutaneous coronary interventions Gogas, Bill D. Glob Cardiol Sci Pract Review Article Innovations in drug-eluting stents (DES) have substantially reduced rates of in-segment restenosis and early stent thrombosis, improving clinical outcomes following percutaneous coronary interventions (PCI). However a fixed metallic implant in a vessel wall with restored patency and residual disease remains a precipitating factor for sustained local inflammation, in-stent neo-atherosclerosis and impaired vasomotor function increasing the risk for late complications attributed to late or very late stent thrombosis and late target lesion revascularization (TLR) (late catch-up). The quest for optimal coronary stenting continues by further innovations in stent design and by using biocompatible materials other than cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding, local drug-elution and future restoration of vessel anatomy, physiology and local hemodynamics have been recently developed. These devices have been utilized in selected clinical applications so far providing preliminary evidence of safety showing comparable performance with current generation drug-eluting stents (DES). Herein we provide a comprehensive overview of the current status of these technologies, we elaborate on the potential benefits of transient coronary scaffolds over permanent stents in the context of vascular reparation therapy, and we further focus on the evolving challenges these devices have to overcome to compete with current generation DES. Condensed Abstract:: The quest for optimizing percutaneous coronary interventions continues by iterative innovations in device materials beyond cobalt chromium, platinum chromium or stainless steel for engineering coronary implants. Bioresorbable scaffolds made of biodegradable polymers or biocorrodible metals with properties of transient vessel scaffolding; local drug-elution and future restoration of vessel anatomy, physiology and local hemodynamics were recently developed. These devices have been utilized in selected clinical applications providing preliminary evidence of safety showing comparable intermediate term clinical outcomes with current generation drug-eluting stents. Bloomsbury Qatar Foundation Journals 2014-12-31 /pmc/articles/PMC4355515/ /pubmed/25780795 http://dx.doi.org/10.5339/gcsp.2014.55 Text en © 2014 Gogas, licensee Bloomsbury Qatar Foundation Journals. This is an open access article distributed under the terms of the Creative Commons Attribution license CC BY 4.0, which permits unrestricted use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Gogas, Bill D.
Bioresorbable scaffolds for percutaneous coronary interventions
title Bioresorbable scaffolds for percutaneous coronary interventions
title_full Bioresorbable scaffolds for percutaneous coronary interventions
title_fullStr Bioresorbable scaffolds for percutaneous coronary interventions
title_full_unstemmed Bioresorbable scaffolds for percutaneous coronary interventions
title_short Bioresorbable scaffolds for percutaneous coronary interventions
title_sort bioresorbable scaffolds for percutaneous coronary interventions
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4355515/
https://www.ncbi.nlm.nih.gov/pubmed/25780795
http://dx.doi.org/10.5339/gcsp.2014.55
work_keys_str_mv AT gogasbilld bioresorbablescaffoldsforpercutaneouscoronaryinterventions