Cargando…

Impact of different beam directions on intensity-modulated radiation therapy dose delivered to functioning lung tissue identified using single-photon emission computed tomography

AIM OF THE STUDY: To use different beam arrangements and numbers to plan intensity-modulated radiation therapy (IMRT) and investigate their effects on low and high radiation doses delivered to the functional lung, in order to reduce radiation-induced lung damage. MATERIAL AND METHODS: Ten patients w...

Descripción completa

Detalles Bibliográficos
Autores principales: Tian, Qin, Zhang, Fucheng, Wang, Yanming, Qu, Weiqiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4355654/
https://www.ncbi.nlm.nih.gov/pubmed/25784844
http://dx.doi.org/10.5114/wo.2014.46237
_version_ 1782360896493846528
author Tian, Qin
Zhang, Fucheng
Wang, Yanming
Qu, Weiqiang
author_facet Tian, Qin
Zhang, Fucheng
Wang, Yanming
Qu, Weiqiang
author_sort Tian, Qin
collection PubMed
description AIM OF THE STUDY: To use different beam arrangements and numbers to plan intensity-modulated radiation therapy (IMRT) and investigate their effects on low and high radiation doses delivered to the functional lung, in order to reduce radiation-induced lung damage. MATERIAL AND METHODS: Ten patients with stage I–III non-small cell lung carcinoma (NSCLC) underwent IMRT. Beam arrangements were selected on the basis of orientation and dose-volume histograms to create SPECT-guided IMRT plans that spared the functional lung and maintained target coverage. Four different plans, including CT-7, SPECT-7, SPECT-4, SPECT-5 with different beam arrangements, were used. The differences of conformity index (CI), heterogeneity index (HI) between the plans were analyzed, by using a paired t-test. RESULTS: The seven-beam SPECT (SPECT-7) plan reduced the volume of the functional lung irradiated with at least 20 Gy (FV20) and 30 Gy (FV30) by 26.02% ±15.45% and 14.41% ±16.66%, respectively, as compared to the seven-beam computed tomography (CT-7) plan. The CI significantly differed between the SPECT-7 and SPECT-4 plans and between the SPECT-5 and SPECT-4 plans, but not between the SPECT-5 and SPECT-7 plans. The CIs in the SPECT-5 and SPECT-7 plans were better than that in the SPECT-4 plan. The heterogeneity index significantly differed among the three SPECT plans and was best in the SPECT-7 plan. CONCLUSIONS: The incorporation of SPECT images into IMRT planning for NSCLC greatly affected beam angles and number of beams. Fewer beams and modified beam angles achieved similar or better IMRT quality. The low-dose volumes were lower in SPECT-4.
format Online
Article
Text
id pubmed-4355654
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-43556542015-03-17 Impact of different beam directions on intensity-modulated radiation therapy dose delivered to functioning lung tissue identified using single-photon emission computed tomography Tian, Qin Zhang, Fucheng Wang, Yanming Qu, Weiqiang Contemp Oncol (Pozn) Original Paper AIM OF THE STUDY: To use different beam arrangements and numbers to plan intensity-modulated radiation therapy (IMRT) and investigate their effects on low and high radiation doses delivered to the functional lung, in order to reduce radiation-induced lung damage. MATERIAL AND METHODS: Ten patients with stage I–III non-small cell lung carcinoma (NSCLC) underwent IMRT. Beam arrangements were selected on the basis of orientation and dose-volume histograms to create SPECT-guided IMRT plans that spared the functional lung and maintained target coverage. Four different plans, including CT-7, SPECT-7, SPECT-4, SPECT-5 with different beam arrangements, were used. The differences of conformity index (CI), heterogeneity index (HI) between the plans were analyzed, by using a paired t-test. RESULTS: The seven-beam SPECT (SPECT-7) plan reduced the volume of the functional lung irradiated with at least 20 Gy (FV20) and 30 Gy (FV30) by 26.02% ±15.45% and 14.41% ±16.66%, respectively, as compared to the seven-beam computed tomography (CT-7) plan. The CI significantly differed between the SPECT-7 and SPECT-4 plans and between the SPECT-5 and SPECT-4 plans, but not between the SPECT-5 and SPECT-7 plans. The CIs in the SPECT-5 and SPECT-7 plans were better than that in the SPECT-4 plan. The heterogeneity index significantly differed among the three SPECT plans and was best in the SPECT-7 plan. CONCLUSIONS: The incorporation of SPECT images into IMRT planning for NSCLC greatly affected beam angles and number of beams. Fewer beams and modified beam angles achieved similar or better IMRT quality. The low-dose volumes were lower in SPECT-4. Termedia Publishing House 2014-11-12 2014 /pmc/articles/PMC4355654/ /pubmed/25784844 http://dx.doi.org/10.5114/wo.2014.46237 Text en Copyright © 2014 Termedia http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Paper
Tian, Qin
Zhang, Fucheng
Wang, Yanming
Qu, Weiqiang
Impact of different beam directions on intensity-modulated radiation therapy dose delivered to functioning lung tissue identified using single-photon emission computed tomography
title Impact of different beam directions on intensity-modulated radiation therapy dose delivered to functioning lung tissue identified using single-photon emission computed tomography
title_full Impact of different beam directions on intensity-modulated radiation therapy dose delivered to functioning lung tissue identified using single-photon emission computed tomography
title_fullStr Impact of different beam directions on intensity-modulated radiation therapy dose delivered to functioning lung tissue identified using single-photon emission computed tomography
title_full_unstemmed Impact of different beam directions on intensity-modulated radiation therapy dose delivered to functioning lung tissue identified using single-photon emission computed tomography
title_short Impact of different beam directions on intensity-modulated radiation therapy dose delivered to functioning lung tissue identified using single-photon emission computed tomography
title_sort impact of different beam directions on intensity-modulated radiation therapy dose delivered to functioning lung tissue identified using single-photon emission computed tomography
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4355654/
https://www.ncbi.nlm.nih.gov/pubmed/25784844
http://dx.doi.org/10.5114/wo.2014.46237
work_keys_str_mv AT tianqin impactofdifferentbeamdirectionsonintensitymodulatedradiationtherapydosedeliveredtofunctioninglungtissueidentifiedusingsinglephotonemissioncomputedtomography
AT zhangfucheng impactofdifferentbeamdirectionsonintensitymodulatedradiationtherapydosedeliveredtofunctioninglungtissueidentifiedusingsinglephotonemissioncomputedtomography
AT wangyanming impactofdifferentbeamdirectionsonintensitymodulatedradiationtherapydosedeliveredtofunctioninglungtissueidentifiedusingsinglephotonemissioncomputedtomography
AT quweiqiang impactofdifferentbeamdirectionsonintensitymodulatedradiationtherapydosedeliveredtofunctioninglungtissueidentifiedusingsinglephotonemissioncomputedtomography