Cargando…
Worldwide Enucleation Techniques and Materials for Treatment of Retinoblastoma: An International Survey
PURPOSE: To investigate the current practice of enucleation with or without orbital implant for retinoblastoma in countries across the world. METHODS: A digital survey identifying operation techniques and material used for orbital implants after enucleation in patients with retinoblastoma. RESULTS:...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4358947/ https://www.ncbi.nlm.nih.gov/pubmed/25767872 http://dx.doi.org/10.1371/journal.pone.0121292 |
_version_ | 1782361315152494592 |
---|---|
author | Mourits, Daphne L. Hartong, Dyonne T. Bosscha, Machteld I. Kloos, Roel J. H. M. Moll, Annette C. |
author_facet | Mourits, Daphne L. Hartong, Dyonne T. Bosscha, Machteld I. Kloos, Roel J. H. M. Moll, Annette C. |
author_sort | Mourits, Daphne L. |
collection | PubMed |
description | PURPOSE: To investigate the current practice of enucleation with or without orbital implant for retinoblastoma in countries across the world. METHODS: A digital survey identifying operation techniques and material used for orbital implants after enucleation in patients with retinoblastoma. RESULTS: We received a response of 58 surgeons in 32 different countries. A primary artificial implant is routinely inserted by 42 (72.4%) surgeons. Ten (17.2%) surgeons leave the socket empty, three (5.2%) decide per case. Other surgeons insert a dermis fat graft as a standard primary implant (n=1), or fill the socket in a standard secondary procedure (n=2; one uses dermis fat grafts and one artificial implants). The choice for porous implants was more frequent than for non-porous implants: 27 (58.7%) and 15 (32.6%), respectively. Both porous and non-porous implant types are used by 4 (8.7%) surgeons. Twenty-five surgeons (54.3%) insert bare implants, 11 (23.9%) use separate wrappings, eight (17.4%) use implants with prefab wrapping and two insert implants with and without wrapping depending on type of implant. Attachment of the muscles to the wrapping or implant (at various locations) is done by 31 (53.4%) surgeons. Eleven (19.0%) use a myoconjunctival technique, nine (15.5%) suture the muscles to each other and seven (12.1%) do not reattach the muscles. Measures to improve volume are implant exchange at an older age (n=4), the use of Restylane SQ (n=1) and osmotic expanders (n=1). Pegging is done by two surgeons. CONCLUSION: No (worldwide) consensus exists about the use of material and techniques for enucleation for the treatment of retinoblastoma. Considerations for the use of different techniques are discussed. |
format | Online Article Text |
id | pubmed-4358947 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-43589472015-03-23 Worldwide Enucleation Techniques and Materials for Treatment of Retinoblastoma: An International Survey Mourits, Daphne L. Hartong, Dyonne T. Bosscha, Machteld I. Kloos, Roel J. H. M. Moll, Annette C. PLoS One Research Article PURPOSE: To investigate the current practice of enucleation with or without orbital implant for retinoblastoma in countries across the world. METHODS: A digital survey identifying operation techniques and material used for orbital implants after enucleation in patients with retinoblastoma. RESULTS: We received a response of 58 surgeons in 32 different countries. A primary artificial implant is routinely inserted by 42 (72.4%) surgeons. Ten (17.2%) surgeons leave the socket empty, three (5.2%) decide per case. Other surgeons insert a dermis fat graft as a standard primary implant (n=1), or fill the socket in a standard secondary procedure (n=2; one uses dermis fat grafts and one artificial implants). The choice for porous implants was more frequent than for non-porous implants: 27 (58.7%) and 15 (32.6%), respectively. Both porous and non-porous implant types are used by 4 (8.7%) surgeons. Twenty-five surgeons (54.3%) insert bare implants, 11 (23.9%) use separate wrappings, eight (17.4%) use implants with prefab wrapping and two insert implants with and without wrapping depending on type of implant. Attachment of the muscles to the wrapping or implant (at various locations) is done by 31 (53.4%) surgeons. Eleven (19.0%) use a myoconjunctival technique, nine (15.5%) suture the muscles to each other and seven (12.1%) do not reattach the muscles. Measures to improve volume are implant exchange at an older age (n=4), the use of Restylane SQ (n=1) and osmotic expanders (n=1). Pegging is done by two surgeons. CONCLUSION: No (worldwide) consensus exists about the use of material and techniques for enucleation for the treatment of retinoblastoma. Considerations for the use of different techniques are discussed. Public Library of Science 2015-03-13 /pmc/articles/PMC4358947/ /pubmed/25767872 http://dx.doi.org/10.1371/journal.pone.0121292 Text en © 2015 Mourits et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Mourits, Daphne L. Hartong, Dyonne T. Bosscha, Machteld I. Kloos, Roel J. H. M. Moll, Annette C. Worldwide Enucleation Techniques and Materials for Treatment of Retinoblastoma: An International Survey |
title | Worldwide Enucleation Techniques and Materials for Treatment of Retinoblastoma: An International Survey |
title_full | Worldwide Enucleation Techniques and Materials for Treatment of Retinoblastoma: An International Survey |
title_fullStr | Worldwide Enucleation Techniques and Materials for Treatment of Retinoblastoma: An International Survey |
title_full_unstemmed | Worldwide Enucleation Techniques and Materials for Treatment of Retinoblastoma: An International Survey |
title_short | Worldwide Enucleation Techniques and Materials for Treatment of Retinoblastoma: An International Survey |
title_sort | worldwide enucleation techniques and materials for treatment of retinoblastoma: an international survey |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4358947/ https://www.ncbi.nlm.nih.gov/pubmed/25767872 http://dx.doi.org/10.1371/journal.pone.0121292 |
work_keys_str_mv | AT mouritsdaphnel worldwideenucleationtechniquesandmaterialsfortreatmentofretinoblastomaaninternationalsurvey AT hartongdyonnet worldwideenucleationtechniquesandmaterialsfortreatmentofretinoblastomaaninternationalsurvey AT bosschamachteldi worldwideenucleationtechniquesandmaterialsfortreatmentofretinoblastomaaninternationalsurvey AT kloosroeljhm worldwideenucleationtechniquesandmaterialsfortreatmentofretinoblastomaaninternationalsurvey AT mollannettec worldwideenucleationtechniquesandmaterialsfortreatmentofretinoblastomaaninternationalsurvey |