Cargando…

Restricted versus Standard Maintenance Fluid Volume in Management of Transient Tachypnea of Newborn: A Clinical Trial

Objective: The incidence of Transient Tachypnea of Newborn (TTN) is higher in infants born by cesarean section than with  vaginal delivery. Treatment of transient tachypnea of newborn is supportive. The purpose of this study was to assess the effect of restricted fluid volume intake on the course of...

Descripción completa

Detalles Bibliográficos
Autores principales: Dehdashtian, Masoud, Aramesh, Mohammad-Reza, Melekian, Arash, Aletayeb, Mohammad-Hasan, Ghaemmaghami, Anahita
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Tehran University of Medical Sciences 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4359410/
https://www.ncbi.nlm.nih.gov/pubmed/25793064
_version_ 1782361400380751872
author Dehdashtian, Masoud
Aramesh, Mohammad-Reza
Melekian, Arash
Aletayeb, Mohammad-Hasan
Ghaemmaghami, Anahita
author_facet Dehdashtian, Masoud
Aramesh, Mohammad-Reza
Melekian, Arash
Aletayeb, Mohammad-Hasan
Ghaemmaghami, Anahita
author_sort Dehdashtian, Masoud
collection PubMed
description Objective: The incidence of Transient Tachypnea of Newborn (TTN) is higher in infants born by cesarean section than with  vaginal delivery. Treatment of transient tachypnea of newborn is supportive. The purpose of this study was to assess the effect of restricted fluid volume intake on the course of respiratory distress in patients with TTN. Methods: This is a quasi-experimental clinical trial of 83 neonates diagnosed with TTN admitted to a neonatal intensive care unit in south west Iran. In this study the effect of restriction of maintenance fluid volume in the course of respiratory distress in newborns with transient tachypnea was assessed. Findings: In the standard fluid volume intake group 18 (42.8%) cases needed nasal continuous positive airway pressure (NCPAP) and one (2.38%) case mechanical ventilation, and in restricted fluid volume intake group 13 (32.5%) cases needed NCPAP and two (5%) cases mechanical ventilation. 54.82% of cases were supported with oxyhood in the standard fluid volume and 62.5% in the restricted fluid volume intake group. Differences in duration of the needed NCPAP and oxygen hood between the two groups were significant. Fluid restriction had no adverse effect on the urine specific gravity or weight loss of the studied newborns. Conclusion: Limited fluid administered to newborns with transient tachypnea of newborn is safe and resulted in shorter duration of respiratory support.
format Online
Article
Text
id pubmed-4359410
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Tehran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-43594102015-03-19 Restricted versus Standard Maintenance Fluid Volume in Management of Transient Tachypnea of Newborn: A Clinical Trial Dehdashtian, Masoud Aramesh, Mohammad-Reza Melekian, Arash Aletayeb, Mohammad-Hasan Ghaemmaghami, Anahita Iran J Pediatr Original Article Objective: The incidence of Transient Tachypnea of Newborn (TTN) is higher in infants born by cesarean section than with  vaginal delivery. Treatment of transient tachypnea of newborn is supportive. The purpose of this study was to assess the effect of restricted fluid volume intake on the course of respiratory distress in patients with TTN. Methods: This is a quasi-experimental clinical trial of 83 neonates diagnosed with TTN admitted to a neonatal intensive care unit in south west Iran. In this study the effect of restriction of maintenance fluid volume in the course of respiratory distress in newborns with transient tachypnea was assessed. Findings: In the standard fluid volume intake group 18 (42.8%) cases needed nasal continuous positive airway pressure (NCPAP) and one (2.38%) case mechanical ventilation, and in restricted fluid volume intake group 13 (32.5%) cases needed NCPAP and two (5%) cases mechanical ventilation. 54.82% of cases were supported with oxyhood in the standard fluid volume and 62.5% in the restricted fluid volume intake group. Differences in duration of the needed NCPAP and oxygen hood between the two groups were significant. Fluid restriction had no adverse effect on the urine specific gravity or weight loss of the studied newborns. Conclusion: Limited fluid administered to newborns with transient tachypnea of newborn is safe and resulted in shorter duration of respiratory support. Tehran University of Medical Sciences 2014-10 2014-10-01 /pmc/articles/PMC4359410/ /pubmed/25793064 Text en Copyright © 2014 by Pediatrics Center of Excellence, Children’s Medical Center, Tehran University of Medical Sciences, All rights reserved This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Dehdashtian, Masoud
Aramesh, Mohammad-Reza
Melekian, Arash
Aletayeb, Mohammad-Hasan
Ghaemmaghami, Anahita
Restricted versus Standard Maintenance Fluid Volume in Management of Transient Tachypnea of Newborn: A Clinical Trial
title Restricted versus Standard Maintenance Fluid Volume in Management of Transient Tachypnea of Newborn: A Clinical Trial
title_full Restricted versus Standard Maintenance Fluid Volume in Management of Transient Tachypnea of Newborn: A Clinical Trial
title_fullStr Restricted versus Standard Maintenance Fluid Volume in Management of Transient Tachypnea of Newborn: A Clinical Trial
title_full_unstemmed Restricted versus Standard Maintenance Fluid Volume in Management of Transient Tachypnea of Newborn: A Clinical Trial
title_short Restricted versus Standard Maintenance Fluid Volume in Management of Transient Tachypnea of Newborn: A Clinical Trial
title_sort restricted versus standard maintenance fluid volume in management of transient tachypnea of newborn: a clinical trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4359410/
https://www.ncbi.nlm.nih.gov/pubmed/25793064
work_keys_str_mv AT dehdashtianmasoud restrictedversusstandardmaintenancefluidvolumeinmanagementoftransienttachypneaofnewbornaclinicaltrial
AT arameshmohammadreza restrictedversusstandardmaintenancefluidvolumeinmanagementoftransienttachypneaofnewbornaclinicaltrial
AT melekianarash restrictedversusstandardmaintenancefluidvolumeinmanagementoftransienttachypneaofnewbornaclinicaltrial
AT aletayebmohammadhasan restrictedversusstandardmaintenancefluidvolumeinmanagementoftransienttachypneaofnewbornaclinicaltrial
AT ghaemmaghamianahita restrictedversusstandardmaintenancefluidvolumeinmanagementoftransienttachypneaofnewbornaclinicaltrial