Cargando…

Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status?

BACKGROUND: Although the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) is considered the leading outcome measure for patients with osteoarthritis of the lower extremity, recent work has challenged its factorial validity and the physical function subscale's ability to dete...

Descripción completa

Detalles Bibliográficos
Autores principales: Stratford, Paul W, Kennedy, Deborah M
Formato: Texto
Lenguaje:English
Publicado: BioMed Central 2004
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC436062/
https://www.ncbi.nlm.nih.gov/pubmed/15189563
http://dx.doi.org/10.1186/1471-2474-5-17
_version_ 1782121529932251136
author Stratford, Paul W
Kennedy, Deborah M
author_facet Stratford, Paul W
Kennedy, Deborah M
author_sort Stratford, Paul W
collection PubMed
description BACKGROUND: Although the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) is considered the leading outcome measure for patients with osteoarthritis of the lower extremity, recent work has challenged its factorial validity and the physical function subscale's ability to detect valid change when pain and function display different profiles of change. This study examined the etiology of the WOMAC's physical function subscale's limited ability to detect change in the presence of discordant changes for pain and function. We hypothesized that the duplication of some items on the WOMAC's pain and function subscales contributed to this shortcoming. METHODS: Two eight-item physical function scales were abstracted from the WOMAC's 17-item physical function subscale: one contained activities and themes that were duplicated on the pain subscale (SIMILAR-8); the other version avoided overlapping activities (DISSIMILAR-8). Factorial validity of the shortened measures was assessed on 310 patients awaiting hip or knee arthroplasty. The shortened measures' abilities to detect change were examined on a sample of 104 patients following primary hip or knee arthroplasty. The WOMAC and three performance measures that included activity specific pain assessments – 40 m walk test, stair test, and timed-up-and-go test – were administered preoperatively, within 16 days of hip or knee arthroplasty, and at an interval of greater than 20 days following the first post-surgical assessment. Standardized response means were used to quantify change. RESULTS: The SIMILAR-8 did not demonstrate factorial validity; however, the factorial structure of the DISSIMILAR-8 was supported. The time to complete the performance measures more than doubled between the preoperative and first postoperative assessments supporting the theory that lower extremity functional status diminished over this interval. The DISSIMILAR-8 detected this deterioration in functional status; however, no significant change was noted for the SIMILAR-8. The WOMAC pain scale demonstrated a slight reduction in pain and the performance specific pain measures did not reflect a change in pain. All measures showed substantial improvement over the second assessment interval. CONCLUSIONS: These findings support the hypothesis that activity overlap on the pain and function subscales plays a causal role in limiting the WOMAC physical function subscale's ability to detect change.
format Text
id pubmed-436062
institution National Center for Biotechnology Information
language English
publishDate 2004
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-4360622004-06-26 Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status? Stratford, Paul W Kennedy, Deborah M BMC Musculoskelet Disord Research Article BACKGROUND: Although the Western Ontario and McMaster University Osteoarthritis Index (WOMAC) is considered the leading outcome measure for patients with osteoarthritis of the lower extremity, recent work has challenged its factorial validity and the physical function subscale's ability to detect valid change when pain and function display different profiles of change. This study examined the etiology of the WOMAC's physical function subscale's limited ability to detect change in the presence of discordant changes for pain and function. We hypothesized that the duplication of some items on the WOMAC's pain and function subscales contributed to this shortcoming. METHODS: Two eight-item physical function scales were abstracted from the WOMAC's 17-item physical function subscale: one contained activities and themes that were duplicated on the pain subscale (SIMILAR-8); the other version avoided overlapping activities (DISSIMILAR-8). Factorial validity of the shortened measures was assessed on 310 patients awaiting hip or knee arthroplasty. The shortened measures' abilities to detect change were examined on a sample of 104 patients following primary hip or knee arthroplasty. The WOMAC and three performance measures that included activity specific pain assessments – 40 m walk test, stair test, and timed-up-and-go test – were administered preoperatively, within 16 days of hip or knee arthroplasty, and at an interval of greater than 20 days following the first post-surgical assessment. Standardized response means were used to quantify change. RESULTS: The SIMILAR-8 did not demonstrate factorial validity; however, the factorial structure of the DISSIMILAR-8 was supported. The time to complete the performance measures more than doubled between the preoperative and first postoperative assessments supporting the theory that lower extremity functional status diminished over this interval. The DISSIMILAR-8 detected this deterioration in functional status; however, no significant change was noted for the SIMILAR-8. The WOMAC pain scale demonstrated a slight reduction in pain and the performance specific pain measures did not reflect a change in pain. All measures showed substantial improvement over the second assessment interval. CONCLUSIONS: These findings support the hypothesis that activity overlap on the pain and function subscales plays a causal role in limiting the WOMAC physical function subscale's ability to detect change. BioMed Central 2004-06-09 /pmc/articles/PMC436062/ /pubmed/15189563 http://dx.doi.org/10.1186/1471-2474-5-17 Text en Copyright © 2004 Stratford and Kennedy; licensee BioMed Central Ltd. This is an Open Access article: verbatim copying and redistribution of this article are permitted in all media for any purpose, provided this notice is preserved along with the article's original URL.
spellingShingle Research Article
Stratford, Paul W
Kennedy, Deborah M
Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status?
title Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status?
title_full Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status?
title_fullStr Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status?
title_full_unstemmed Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status?
title_short Does parallel item content on WOMAC's Pain and Function Subscales limit its ability to detect change in functional status?
title_sort does parallel item content on womac's pain and function subscales limit its ability to detect change in functional status?
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC436062/
https://www.ncbi.nlm.nih.gov/pubmed/15189563
http://dx.doi.org/10.1186/1471-2474-5-17
work_keys_str_mv AT stratfordpaulw doesparallelitemcontentonwomacspainandfunctionsubscaleslimititsabilitytodetectchangeinfunctionalstatus
AT kennedydeborahm doesparallelitemcontentonwomacspainandfunctionsubscaleslimititsabilitytodetectchangeinfunctionalstatus