Cargando…
Special Report: 26-Year Durability of a Bioprosthesis Implanted in a 21-Year-Old Patient
The choice of prosthetic heart valve type is largely dependent upon patient's age at implantation and on what, in his eyes, seems more pertinent: avoidance of complications associated with anticoagulation of mechanical valves or structural valve deterioration of bioprosthetic valves. Long lasti...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4360689/ https://www.ncbi.nlm.nih.gov/pubmed/25798348 http://dx.doi.org/10.1055/s-0034-1364323 |
_version_ | 1782361567673712640 |
---|---|
author | Holst, Torulv Reichert, Josef Haldenwang, Peter Moustafine, Vadim Bechtel, Matthias Strauch, Justus Knipp, Stephan |
author_facet | Holst, Torulv Reichert, Josef Haldenwang, Peter Moustafine, Vadim Bechtel, Matthias Strauch, Justus Knipp, Stephan |
author_sort | Holst, Torulv |
collection | PubMed |
description | The choice of prosthetic heart valve type is largely dependent upon patient's age at implantation and on what, in his eyes, seems more pertinent: avoidance of complications associated with anticoagulation of mechanical valves or structural valve deterioration of bioprosthetic valves. Long lasting and new promising concepts such as transcatheter aortic valve implantation are promoting the use of bioprosthesis even in younger patients. However, it is up to the individual patient to decide. |
format | Online Article Text |
id | pubmed-4360689 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-43606892015-03-20 Special Report: 26-Year Durability of a Bioprosthesis Implanted in a 21-Year-Old Patient Holst, Torulv Reichert, Josef Haldenwang, Peter Moustafine, Vadim Bechtel, Matthias Strauch, Justus Knipp, Stephan Thorac Cardiovasc Surg Rep Article The choice of prosthetic heart valve type is largely dependent upon patient's age at implantation and on what, in his eyes, seems more pertinent: avoidance of complications associated with anticoagulation of mechanical valves or structural valve deterioration of bioprosthetic valves. Long lasting and new promising concepts such as transcatheter aortic valve implantation are promoting the use of bioprosthesis even in younger patients. However, it is up to the individual patient to decide. Georg Thieme Verlag KG 2014-02-27 2014-12 /pmc/articles/PMC4360689/ /pubmed/25798348 http://dx.doi.org/10.1055/s-0034-1364323 Text en © Thieme Medical Publishers |
spellingShingle | Article Holst, Torulv Reichert, Josef Haldenwang, Peter Moustafine, Vadim Bechtel, Matthias Strauch, Justus Knipp, Stephan Special Report: 26-Year Durability of a Bioprosthesis Implanted in a 21-Year-Old Patient |
title | Special Report: 26-Year Durability of a Bioprosthesis Implanted in a 21-Year-Old Patient |
title_full | Special Report: 26-Year Durability of a Bioprosthesis Implanted in a 21-Year-Old Patient |
title_fullStr | Special Report: 26-Year Durability of a Bioprosthesis Implanted in a 21-Year-Old Patient |
title_full_unstemmed | Special Report: 26-Year Durability of a Bioprosthesis Implanted in a 21-Year-Old Patient |
title_short | Special Report: 26-Year Durability of a Bioprosthesis Implanted in a 21-Year-Old Patient |
title_sort | special report: 26-year durability of a bioprosthesis implanted in a 21-year-old patient |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4360689/ https://www.ncbi.nlm.nih.gov/pubmed/25798348 http://dx.doi.org/10.1055/s-0034-1364323 |
work_keys_str_mv | AT holsttorulv specialreport26yeardurabilityofabioprosthesisimplantedina21yearoldpatient AT reichertjosef specialreport26yeardurabilityofabioprosthesisimplantedina21yearoldpatient AT haldenwangpeter specialreport26yeardurabilityofabioprosthesisimplantedina21yearoldpatient AT moustafinevadim specialreport26yeardurabilityofabioprosthesisimplantedina21yearoldpatient AT bechtelmatthias specialreport26yeardurabilityofabioprosthesisimplantedina21yearoldpatient AT strauchjustus specialreport26yeardurabilityofabioprosthesisimplantedina21yearoldpatient AT knippstephan specialreport26yeardurabilityofabioprosthesisimplantedina21yearoldpatient |