Cargando…

Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour

Most overuse tendinopathies are thought to be associated with repeated microstrain below the failure threshold, analogous to the fatigue failure that affects materials placed under repetitive loading. Investigating the progression of fatigue damage within tendons is therefore of critical importance....

Descripción completa

Detalles Bibliográficos
Autores principales: Shepherd, Jennifer H, Legerlotz, Kirsten, Demirci, Taylan, Klemt, Christian, Riley, Graham P, Screen, Hazel RC
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2013
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4361498/
https://www.ncbi.nlm.nih.gov/pubmed/24285289
http://dx.doi.org/10.1177/0954411913509977
_version_ 1782361642288283648
author Shepherd, Jennifer H
Legerlotz, Kirsten
Demirci, Taylan
Klemt, Christian
Riley, Graham P
Screen, Hazel RC
author_facet Shepherd, Jennifer H
Legerlotz, Kirsten
Demirci, Taylan
Klemt, Christian
Riley, Graham P
Screen, Hazel RC
author_sort Shepherd, Jennifer H
collection PubMed
description Most overuse tendinopathies are thought to be associated with repeated microstrain below the failure threshold, analogous to the fatigue failure that affects materials placed under repetitive loading. Investigating the progression of fatigue damage within tendons is therefore of critical importance. There are obvious challenges associated with the sourcing of human tendon samples for in vitro analysis so animal models are regularly adopted. However, data indicates that fatigue life varies significantly between tendons of different species and with different stresses in life. Positional tendons such as rat tail tendon or the bovine digital extensor are commonly applied in in vitro studies of tendon overuse, but there is no evidence to suggest their behaviour is indicative of the types of human tendon particularly prone to overuse injuries. In this study, the fatigue response of the largely positional digital extensor and the more energy storing deep digital flexor tendon of the bovine hoof were compared to the semitendinosus tendon of the human hamstring. Fascicles from each tendon type were subjected to either stress or strain controlled fatigue loading (cyclic creep or cyclic stress relaxation respectively). Gross fascicle mechanics were monitored after cyclic stress relaxation and the mean number of cycles to failure investigated with creep loading. Bovine extensor fascicles demonstrated the poorest fatigue response, while the energy storing human semitendinosus was the most fatigue resistant. Despite the superior fatigue response of the energy storing tendons, confocal imaging suggested a similar degree of damage in all three tendon types; it appears the more energy storing tendons are better able to withstand damage without detriment to mechanics.
format Online
Article
Text
id pubmed-4361498
institution National Center for Biotechnology Information
language English
publishDate 2013
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-43614982015-04-10 Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour Shepherd, Jennifer H Legerlotz, Kirsten Demirci, Taylan Klemt, Christian Riley, Graham P Screen, Hazel RC Proc Inst Mech Eng H Original Articles Most overuse tendinopathies are thought to be associated with repeated microstrain below the failure threshold, analogous to the fatigue failure that affects materials placed under repetitive loading. Investigating the progression of fatigue damage within tendons is therefore of critical importance. There are obvious challenges associated with the sourcing of human tendon samples for in vitro analysis so animal models are regularly adopted. However, data indicates that fatigue life varies significantly between tendons of different species and with different stresses in life. Positional tendons such as rat tail tendon or the bovine digital extensor are commonly applied in in vitro studies of tendon overuse, but there is no evidence to suggest their behaviour is indicative of the types of human tendon particularly prone to overuse injuries. In this study, the fatigue response of the largely positional digital extensor and the more energy storing deep digital flexor tendon of the bovine hoof were compared to the semitendinosus tendon of the human hamstring. Fascicles from each tendon type were subjected to either stress or strain controlled fatigue loading (cyclic creep or cyclic stress relaxation respectively). Gross fascicle mechanics were monitored after cyclic stress relaxation and the mean number of cycles to failure investigated with creep loading. Bovine extensor fascicles demonstrated the poorest fatigue response, while the energy storing human semitendinosus was the most fatigue resistant. Despite the superior fatigue response of the energy storing tendons, confocal imaging suggested a similar degree of damage in all three tendon types; it appears the more energy storing tendons are better able to withstand damage without detriment to mechanics. SAGE Publications 2013-11-27 2014-01 /pmc/articles/PMC4361498/ /pubmed/24285289 http://dx.doi.org/10.1177/0954411913509977 Text en © IMechE 2013 http://creativecommons.org/licenses/by/3.0/ This article is distributed under the terms of the Creative Commons Attribution 3.0 License (http://www.creativecommons.org/licenses/by/3.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (http://www.uk.sagepub.com/aboutus/openaccess.htm).
spellingShingle Original Articles
Shepherd, Jennifer H
Legerlotz, Kirsten
Demirci, Taylan
Klemt, Christian
Riley, Graham P
Screen, Hazel RC
Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour
title Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour
title_full Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour
title_fullStr Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour
title_full_unstemmed Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour
title_short Functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour
title_sort functionally distinct tendon fascicles exhibit different creep and stress relaxation behaviour
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4361498/
https://www.ncbi.nlm.nih.gov/pubmed/24285289
http://dx.doi.org/10.1177/0954411913509977
work_keys_str_mv AT shepherdjenniferh functionallydistincttendonfasciclesexhibitdifferentcreepandstressrelaxationbehaviour
AT legerlotzkirsten functionallydistincttendonfasciclesexhibitdifferentcreepandstressrelaxationbehaviour
AT demircitaylan functionallydistincttendonfasciclesexhibitdifferentcreepandstressrelaxationbehaviour
AT klemtchristian functionallydistincttendonfasciclesexhibitdifferentcreepandstressrelaxationbehaviour
AT rileygrahamp functionallydistincttendonfasciclesexhibitdifferentcreepandstressrelaxationbehaviour
AT screenhazelrc functionallydistincttendonfasciclesexhibitdifferentcreepandstressrelaxationbehaviour