Cargando…

Non-uniform space charge limited current injection into a nano contact solid

We have developed a two-dimensional (2D) non-uniform model to study the space charge limited (SCL) current injection into a trap-filled solid of nano-contact, such as organic materials and dielectrics. Assuming a solid of length D with a contact of width W, the enhancement over the well-known 1D uni...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhu, Y. B., Ang, L. K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4361851/
https://www.ncbi.nlm.nih.gov/pubmed/25779769
http://dx.doi.org/10.1038/srep09173
_version_ 1782361714683019264
author Zhu, Y. B.
Ang, L. K.
author_facet Zhu, Y. B.
Ang, L. K.
author_sort Zhu, Y. B.
collection PubMed
description We have developed a two-dimensional (2D) non-uniform model to study the space charge limited (SCL) current injection into a trap-filled solid of nano-contact, such as organic materials and dielectrics. Assuming a solid of length D with a contact of width W, the enhancement over the well-known 1D uniform model is calculated as a function of W/D for different material properties, such as the dielectric constant (ε) and the trap distribution. The non-uniform current density profile due to edge effect is predicted. The findings reported here are different from the prior uniform 2D models, which are significant for small W/D when the size of the contact reaching nanometer scale, i.e. W = 50 nm for D = 1 μm. This model will be useful for the characterization of carrier mobility and properties of traps, which are critical to many novel devices (with small nano-contact) operating in the space charge limited condition reporting in novel device and its applications. Empirical formulas are given for future comparison with experimental results.
format Online
Article
Text
id pubmed-4361851
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-43618512015-03-19 Non-uniform space charge limited current injection into a nano contact solid Zhu, Y. B. Ang, L. K. Sci Rep Article We have developed a two-dimensional (2D) non-uniform model to study the space charge limited (SCL) current injection into a trap-filled solid of nano-contact, such as organic materials and dielectrics. Assuming a solid of length D with a contact of width W, the enhancement over the well-known 1D uniform model is calculated as a function of W/D for different material properties, such as the dielectric constant (ε) and the trap distribution. The non-uniform current density profile due to edge effect is predicted. The findings reported here are different from the prior uniform 2D models, which are significant for small W/D when the size of the contact reaching nanometer scale, i.e. W = 50 nm for D = 1 μm. This model will be useful for the characterization of carrier mobility and properties of traps, which are critical to many novel devices (with small nano-contact) operating in the space charge limited condition reporting in novel device and its applications. Empirical formulas are given for future comparison with experimental results. Nature Publishing Group 2015-03-17 /pmc/articles/PMC4361851/ /pubmed/25779769 http://dx.doi.org/10.1038/srep09173 Text en Copyright © 2015, Macmillan Publishers Limited. All rights reserved http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article's Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder in order to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Zhu, Y. B.
Ang, L. K.
Non-uniform space charge limited current injection into a nano contact solid
title Non-uniform space charge limited current injection into a nano contact solid
title_full Non-uniform space charge limited current injection into a nano contact solid
title_fullStr Non-uniform space charge limited current injection into a nano contact solid
title_full_unstemmed Non-uniform space charge limited current injection into a nano contact solid
title_short Non-uniform space charge limited current injection into a nano contact solid
title_sort non-uniform space charge limited current injection into a nano contact solid
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4361851/
https://www.ncbi.nlm.nih.gov/pubmed/25779769
http://dx.doi.org/10.1038/srep09173
work_keys_str_mv AT zhuyb nonuniformspacechargelimitedcurrentinjectionintoananocontactsolid
AT anglk nonuniformspacechargelimitedcurrentinjectionintoananocontactsolid