Cargando…
The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine
OBJECTIVES: To evaluate the feasibility of a minimally invasive technique using a titanium expandable device to achieve anatomical restoration of vertebral compression fractures (VCF) of the thoracolumbar spine. METHODS: This prospective study included 27 patients diagnosed with VCF (Magerl classifi...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Saudi Medical Journal
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4362189/ https://www.ncbi.nlm.nih.gov/pubmed/25630005 http://dx.doi.org/10.15537/smj.2015.1.9463 |
_version_ | 1782361776113844224 |
---|---|
author | Baeesa, Saleh S. Krueger, Antonio Aragón, Francisco A. Noriega, David C. |
author_facet | Baeesa, Saleh S. Krueger, Antonio Aragón, Francisco A. Noriega, David C. |
author_sort | Baeesa, Saleh S. |
collection | PubMed |
description | OBJECTIVES: To evaluate the feasibility of a minimally invasive technique using a titanium expandable device to achieve anatomical restoration of vertebral compression fractures (VCF) of the thoracolumbar spine. METHODS: This prospective study included 27 patients diagnosed with VCF (Magerl classification A.1.2, A.1.3, and A.3.1) of the thoracolumbar spine treated with percutaneous cement augmentation using the SpineJack(®) device. The study was conducted in Valladolid University Hospital, Valladolid, Spain from January to December 2012, with a minimum one-year follow up. Preoperative evaluation included visual analogue scale (VAS) for pain, and radiological assessment of the VCF using 3-dimensional computed tomography (3D-CT) scans for measurements of vertebral heights and angles. The patients were followed at 3, 6, and 12 months with clinical VAS and radiological assessments. RESULTS: The procedure was performed in 27 patients with a mean age of 55.9 ± 17.3 years, 55.6% females. All patients underwent surgery within 6 weeks from time of injury. No procedure related complications occurred. Pain measured by VAS score decreased from 7.0 preoperatively to 3.2 within 24 hours, and remained 2.2 at 3 months, 2.1 at 6 months, and 1.5 at 12-months follow-up (p<0.05). Mean height restorations for the anterior was 3.56 mm, central was 2.49, and posterior vertebral was 1.28 mm, and maintained at 12-months follow-up (p=0.001). CONCLUSION: This new percutaneous technique for VCF has shown good clinical results in pain control and the possibility to reduce both vertebral kyphosis angles and fractured endplates seen in 3D-CT scans assessment method. Further studies are needed to confirm those results on larger cohorts with long-term follow up. |
format | Online Article Text |
id | pubmed-4362189 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Saudi Medical Journal |
record_format | MEDLINE/PubMed |
spelling | pubmed-43621892015-03-19 The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine Baeesa, Saleh S. Krueger, Antonio Aragón, Francisco A. Noriega, David C. Saudi Med J Original Article OBJECTIVES: To evaluate the feasibility of a minimally invasive technique using a titanium expandable device to achieve anatomical restoration of vertebral compression fractures (VCF) of the thoracolumbar spine. METHODS: This prospective study included 27 patients diagnosed with VCF (Magerl classification A.1.2, A.1.3, and A.3.1) of the thoracolumbar spine treated with percutaneous cement augmentation using the SpineJack(®) device. The study was conducted in Valladolid University Hospital, Valladolid, Spain from January to December 2012, with a minimum one-year follow up. Preoperative evaluation included visual analogue scale (VAS) for pain, and radiological assessment of the VCF using 3-dimensional computed tomography (3D-CT) scans for measurements of vertebral heights and angles. The patients were followed at 3, 6, and 12 months with clinical VAS and radiological assessments. RESULTS: The procedure was performed in 27 patients with a mean age of 55.9 ± 17.3 years, 55.6% females. All patients underwent surgery within 6 weeks from time of injury. No procedure related complications occurred. Pain measured by VAS score decreased from 7.0 preoperatively to 3.2 within 24 hours, and remained 2.2 at 3 months, 2.1 at 6 months, and 1.5 at 12-months follow-up (p<0.05). Mean height restorations for the anterior was 3.56 mm, central was 2.49, and posterior vertebral was 1.28 mm, and maintained at 12-months follow-up (p=0.001). CONCLUSION: This new percutaneous technique for VCF has shown good clinical results in pain control and the possibility to reduce both vertebral kyphosis angles and fractured endplates seen in 3D-CT scans assessment method. Further studies are needed to confirm those results on larger cohorts with long-term follow up. Saudi Medical Journal 2015 /pmc/articles/PMC4362189/ /pubmed/25630005 http://dx.doi.org/10.15537/smj.2015.1.9463 Text en Copyright: © Saudi Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Baeesa, Saleh S. Krueger, Antonio Aragón, Francisco A. Noriega, David C. The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine |
title | The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine |
title_full | The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine |
title_fullStr | The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine |
title_full_unstemmed | The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine |
title_short | The efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine |
title_sort | efficacy of a percutaneous expandable titanium device in anatomical reduction of vertebral compression fractures of the thoracolumbar spine |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4362189/ https://www.ncbi.nlm.nih.gov/pubmed/25630005 http://dx.doi.org/10.15537/smj.2015.1.9463 |
work_keys_str_mv | AT baeesasalehs theefficacyofapercutaneousexpandabletitaniumdeviceinanatomicalreductionofvertebralcompressionfracturesofthethoracolumbarspine AT kruegerantonio theefficacyofapercutaneousexpandabletitaniumdeviceinanatomicalreductionofvertebralcompressionfracturesofthethoracolumbarspine AT aragonfranciscoa theefficacyofapercutaneousexpandabletitaniumdeviceinanatomicalreductionofvertebralcompressionfracturesofthethoracolumbarspine AT noriegadavidc theefficacyofapercutaneousexpandabletitaniumdeviceinanatomicalreductionofvertebralcompressionfracturesofthethoracolumbarspine AT baeesasalehs efficacyofapercutaneousexpandabletitaniumdeviceinanatomicalreductionofvertebralcompressionfracturesofthethoracolumbarspine AT kruegerantonio efficacyofapercutaneousexpandabletitaniumdeviceinanatomicalreductionofvertebralcompressionfracturesofthethoracolumbarspine AT aragonfranciscoa efficacyofapercutaneousexpandabletitaniumdeviceinanatomicalreductionofvertebralcompressionfracturesofthethoracolumbarspine AT noriegadavidc efficacyofapercutaneousexpandabletitaniumdeviceinanatomicalreductionofvertebralcompressionfracturesofthethoracolumbarspine |