Cargando…

Intravenous contrast media application using cone-beam computed tomography in a rabbit model

PURPOSE: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. MATERIALS AND METHODS: CBCT was perfo...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Min-Sung, Kim, Bok-Yeol, Choi, Hwa-Young, Choi, Yoon-Joo, Oh, Song-Hee, Kang, Ju-Hee, Lee, Sae-Rom, Kang, Ju-Han, Kim, Gyu-Tae, Choi, Yong-Suk, Hwang, Eui-Hwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Academy of Oral and Maxillofacial Radiology 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4362989/
https://www.ncbi.nlm.nih.gov/pubmed/25793181
http://dx.doi.org/10.5624/isd.2015.45.1.31
_version_ 1782361863970881536
author Kim, Min-Sung
Kim, Bok-Yeol
Choi, Hwa-Young
Choi, Yoon-Joo
Oh, Song-Hee
Kang, Ju-Hee
Lee, Sae-Rom
Kang, Ju-Han
Kim, Gyu-Tae
Choi, Yong-Suk
Hwang, Eui-Hwan
author_facet Kim, Min-Sung
Kim, Bok-Yeol
Choi, Hwa-Young
Choi, Yoon-Joo
Oh, Song-Hee
Kang, Ju-Hee
Lee, Sae-Rom
Kang, Ju-Han
Kim, Gyu-Tae
Choi, Yong-Suk
Hwang, Eui-Hwan
author_sort Kim, Min-Sung
collection PubMed
description PURPOSE: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. MATERIALS AND METHODS: CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. RESULTS: The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. CONCLUSION: Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.
format Online
Article
Text
id pubmed-4362989
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Korean Academy of Oral and Maxillofacial Radiology
record_format MEDLINE/PubMed
spelling pubmed-43629892015-03-19 Intravenous contrast media application using cone-beam computed tomography in a rabbit model Kim, Min-Sung Kim, Bok-Yeol Choi, Hwa-Young Choi, Yoon-Joo Oh, Song-Hee Kang, Ju-Hee Lee, Sae-Rom Kang, Ju-Han Kim, Gyu-Tae Choi, Yong-Suk Hwang, Eui-Hwan Imaging Sci Dent Original Article PURPOSE: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. MATERIALS AND METHODS: CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. RESULTS: The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. CONCLUSION: Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography. Korean Academy of Oral and Maxillofacial Radiology 2015-03 2015-03-13 /pmc/articles/PMC4362989/ /pubmed/25793181 http://dx.doi.org/10.5624/isd.2015.45.1.31 Text en Copyright © 2015 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Kim, Min-Sung
Kim, Bok-Yeol
Choi, Hwa-Young
Choi, Yoon-Joo
Oh, Song-Hee
Kang, Ju-Hee
Lee, Sae-Rom
Kang, Ju-Han
Kim, Gyu-Tae
Choi, Yong-Suk
Hwang, Eui-Hwan
Intravenous contrast media application using cone-beam computed tomography in a rabbit model
title Intravenous contrast media application using cone-beam computed tomography in a rabbit model
title_full Intravenous contrast media application using cone-beam computed tomography in a rabbit model
title_fullStr Intravenous contrast media application using cone-beam computed tomography in a rabbit model
title_full_unstemmed Intravenous contrast media application using cone-beam computed tomography in a rabbit model
title_short Intravenous contrast media application using cone-beam computed tomography in a rabbit model
title_sort intravenous contrast media application using cone-beam computed tomography in a rabbit model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4362989/
https://www.ncbi.nlm.nih.gov/pubmed/25793181
http://dx.doi.org/10.5624/isd.2015.45.1.31
work_keys_str_mv AT kimminsung intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel
AT kimbokyeol intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel
AT choihwayoung intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel
AT choiyoonjoo intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel
AT ohsonghee intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel
AT kangjuhee intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel
AT leesaerom intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel
AT kangjuhan intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel
AT kimgyutae intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel
AT choiyongsuk intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel
AT hwangeuihwan intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel