Cargando…
Intravenous contrast media application using cone-beam computed tomography in a rabbit model
PURPOSE: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. MATERIALS AND METHODS: CBCT was perfo...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Academy of Oral and Maxillofacial Radiology
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4362989/ https://www.ncbi.nlm.nih.gov/pubmed/25793181 http://dx.doi.org/10.5624/isd.2015.45.1.31 |
_version_ | 1782361863970881536 |
---|---|
author | Kim, Min-Sung Kim, Bok-Yeol Choi, Hwa-Young Choi, Yoon-Joo Oh, Song-Hee Kang, Ju-Hee Lee, Sae-Rom Kang, Ju-Han Kim, Gyu-Tae Choi, Yong-Suk Hwang, Eui-Hwan |
author_facet | Kim, Min-Sung Kim, Bok-Yeol Choi, Hwa-Young Choi, Yoon-Joo Oh, Song-Hee Kang, Ju-Hee Lee, Sae-Rom Kang, Ju-Han Kim, Gyu-Tae Choi, Yong-Suk Hwang, Eui-Hwan |
author_sort | Kim, Min-Sung |
collection | PubMed |
description | PURPOSE: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. MATERIALS AND METHODS: CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. RESULTS: The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. CONCLUSION: Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography. |
format | Online Article Text |
id | pubmed-4362989 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Korean Academy of Oral and Maxillofacial Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-43629892015-03-19 Intravenous contrast media application using cone-beam computed tomography in a rabbit model Kim, Min-Sung Kim, Bok-Yeol Choi, Hwa-Young Choi, Yoon-Joo Oh, Song-Hee Kang, Ju-Hee Lee, Sae-Rom Kang, Ju-Han Kim, Gyu-Tae Choi, Yong-Suk Hwang, Eui-Hwan Imaging Sci Dent Original Article PURPOSE: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. MATERIALS AND METHODS: CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. RESULTS: The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. CONCLUSION: Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography. Korean Academy of Oral and Maxillofacial Radiology 2015-03 2015-03-13 /pmc/articles/PMC4362989/ /pubmed/25793181 http://dx.doi.org/10.5624/isd.2015.45.1.31 Text en Copyright © 2015 by Korean Academy of Oral and Maxillofacial Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Kim, Min-Sung Kim, Bok-Yeol Choi, Hwa-Young Choi, Yoon-Joo Oh, Song-Hee Kang, Ju-Hee Lee, Sae-Rom Kang, Ju-Han Kim, Gyu-Tae Choi, Yong-Suk Hwang, Eui-Hwan Intravenous contrast media application using cone-beam computed tomography in a rabbit model |
title | Intravenous contrast media application using cone-beam computed tomography in a rabbit model |
title_full | Intravenous contrast media application using cone-beam computed tomography in a rabbit model |
title_fullStr | Intravenous contrast media application using cone-beam computed tomography in a rabbit model |
title_full_unstemmed | Intravenous contrast media application using cone-beam computed tomography in a rabbit model |
title_short | Intravenous contrast media application using cone-beam computed tomography in a rabbit model |
title_sort | intravenous contrast media application using cone-beam computed tomography in a rabbit model |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4362989/ https://www.ncbi.nlm.nih.gov/pubmed/25793181 http://dx.doi.org/10.5624/isd.2015.45.1.31 |
work_keys_str_mv | AT kimminsung intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel AT kimbokyeol intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel AT choihwayoung intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel AT choiyoonjoo intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel AT ohsonghee intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel AT kangjuhee intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel AT leesaerom intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel AT kangjuhan intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel AT kimgyutae intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel AT choiyongsuk intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel AT hwangeuihwan intravenouscontrastmediaapplicationusingconebeamcomputedtomographyinarabbitmodel |