Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation

BACKGROUND: To explore the interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on the four-dimensional computed tomography (4DCT) scan for external-beam partial breast irradiation (EB-PBI) during free breathing. METHODS: Patients with a seroma clarity...

Descripción completa

Detalles Bibliográficos
Autores principales: Guo, Bing, Li, Jianbin, Wang, Wei, Xu, Min, Shao, Qian, Zhang, Yingjie, Liang, Chaoqian, Guo, Yanluan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4363049/
https://www.ncbi.nlm.nih.gov/pubmed/25889620
http://dx.doi.org/10.1186/s13014-015-0370-3
_version_ 1782361871556280320
author Guo, Bing
Li, Jianbin
Wang, Wei
Xu, Min
Shao, Qian
Zhang, Yingjie
Liang, Chaoqian
Guo, Yanluan
author_facet Guo, Bing
Li, Jianbin
Wang, Wei
Xu, Min
Shao, Qian
Zhang, Yingjie
Liang, Chaoqian
Guo, Yanluan
author_sort Guo, Bing
collection PubMed
description BACKGROUND: To explore the interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on the four-dimensional computed tomography (4DCT) scan for external-beam partial breast irradiation (EB-PBI) during free breathing. METHODS: Patients with a seroma clarity score (SCS) 3 ~ 5 and ≥5 surgical clips in the lumpectomy cavity after breast-conserving surgery who were recruited for EB-PBI underwent 4DCT simulation. Based on the ten sets of 4DCT images acquired, the tumour bed formed using the clips, the seroma, and both the clips and seroma (defined as TB(C), TB(S) and TB(C+S), respectively) were delineated by five radiation oncologists using specific guidelines. The following parameters were calculated to analyse interobserver variability: volume of the tumour bed (TB(C), TB(S), TB(C+S)), coefficient of variation (COV(C), COV(S), COV(C+S)), and matching degree (MD(C), MD(S), MD(C+S)). RESULTS: The interobserver variability for TB(C) and TB(C+S) and for COV(C) and COV(C+S) were statistically significant (p = 0.021, 0.008, 0.002, 0.015). No significant difference was observed for TB(S) and COV(S) (p = 0.867, 0.061). Significant differences in interobserver variability were observed for MD(C) vs MD(S), MD(C) vs MD(C+S), MD(S) vs MD(C+S) (p = 0.000, 0.032, 0.008), the interobserver variability of MD(S) was smaller than that of MD(C) and MD(C+S) (MD(S) > MD(C+S) > MD(C)). CONCLUSIONS: When the SCS was 3 ~ 5 points and the number of surgical clips was ≥5, interobserver variability was minimal for the delineation of the tumour bed based on seroma.
format Online
Article
Text
id pubmed-4363049
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-43630492015-03-19 Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation Guo, Bing Li, Jianbin Wang, Wei Xu, Min Shao, Qian Zhang, Yingjie Liang, Chaoqian Guo, Yanluan Radiat Oncol Research BACKGROUND: To explore the interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on the four-dimensional computed tomography (4DCT) scan for external-beam partial breast irradiation (EB-PBI) during free breathing. METHODS: Patients with a seroma clarity score (SCS) 3 ~ 5 and ≥5 surgical clips in the lumpectomy cavity after breast-conserving surgery who were recruited for EB-PBI underwent 4DCT simulation. Based on the ten sets of 4DCT images acquired, the tumour bed formed using the clips, the seroma, and both the clips and seroma (defined as TB(C), TB(S) and TB(C+S), respectively) were delineated by five radiation oncologists using specific guidelines. The following parameters were calculated to analyse interobserver variability: volume of the tumour bed (TB(C), TB(S), TB(C+S)), coefficient of variation (COV(C), COV(S), COV(C+S)), and matching degree (MD(C), MD(S), MD(C+S)). RESULTS: The interobserver variability for TB(C) and TB(C+S) and for COV(C) and COV(C+S) were statistically significant (p = 0.021, 0.008, 0.002, 0.015). No significant difference was observed for TB(S) and COV(S) (p = 0.867, 0.061). Significant differences in interobserver variability were observed for MD(C) vs MD(S), MD(C) vs MD(C+S), MD(S) vs MD(C+S) (p = 0.000, 0.032, 0.008), the interobserver variability of MD(S) was smaller than that of MD(C) and MD(C+S) (MD(S) > MD(C+S) > MD(C)). CONCLUSIONS: When the SCS was 3 ~ 5 points and the number of surgical clips was ≥5, interobserver variability was minimal for the delineation of the tumour bed based on seroma. BioMed Central 2015-03-13 /pmc/articles/PMC4363049/ /pubmed/25889620 http://dx.doi.org/10.1186/s13014-015-0370-3 Text en © Guo et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Guo, Bing
Li, Jianbin
Wang, Wei
Xu, Min
Shao, Qian
Zhang, Yingjie
Liang, Chaoqian
Guo, Yanluan
Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation
title Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation
title_full Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation
title_fullStr Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation
title_full_unstemmed Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation
title_short Interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4DCT scan for external-beam partial breast irradiation
title_sort interobserver variability in the delineation of the tumour bed using seroma and surgical clips based on 4dct scan for external-beam partial breast irradiation
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4363049/
https://www.ncbi.nlm.nih.gov/pubmed/25889620
http://dx.doi.org/10.1186/s13014-015-0370-3
work_keys_str_mv AT guobing interobservervariabilityinthedelineationofthetumourbedusingseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiation
AT lijianbin interobservervariabilityinthedelineationofthetumourbedusingseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiation
AT wangwei interobservervariabilityinthedelineationofthetumourbedusingseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiation
AT xumin interobservervariabilityinthedelineationofthetumourbedusingseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiation
AT shaoqian interobservervariabilityinthedelineationofthetumourbedusingseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiation
AT zhangyingjie interobservervariabilityinthedelineationofthetumourbedusingseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiation
AT liangchaoqian interobservervariabilityinthedelineationofthetumourbedusingseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiation
AT guoyanluan interobservervariabilityinthedelineationofthetumourbedusingseromaandsurgicalclipsbasedon4dctscanforexternalbeampartialbreastirradiation