Cargando…
Ocular pressure waveform reflects ventricular bigeminy and aortic insufficiency
Ocular pulse amplitude (OPA) is defined as the difference between maximum and minimum intraocular pressure (IOP) during a cardiac cycle. Average values of OPA range from 1 to 4 mmHg. The purpose of this investigation is to determine the source of an irregular IOP waveform with elevated OPA in a 48-y...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4363960/ https://www.ncbi.nlm.nih.gov/pubmed/25686065 http://dx.doi.org/10.4103/0301-4738.151472 |
_version_ | 1782361998408810496 |
---|---|
author | Kassem, Jean B Katz, Steven E Mahmoud, Ashraf M Small, Robert H Raman, Subha V Roberts, Cynthia J |
author_facet | Kassem, Jean B Katz, Steven E Mahmoud, Ashraf M Small, Robert H Raman, Subha V Roberts, Cynthia J |
author_sort | Kassem, Jean B |
collection | PubMed |
description | Ocular pulse amplitude (OPA) is defined as the difference between maximum and minimum intraocular pressure (IOP) during a cardiac cycle. Average values of OPA range from 1 to 4 mmHg. The purpose of this investigation is to determine the source of an irregular IOP waveform with elevated OPA in a 48-year-old male. Ocular pressure waveforms had an unusual shape consistent with early ventricular contraction. With a normal IOP, OPA was 9 mmHg, which is extraordinarily high. The subject was examined by a cardiologist and was determined to be in ventricular bigeminy. In addition, he had bounding carotid pulses and echocardiogram confirmed aortic insufficiency. After replacement of the aortic valve, the bigeminy resolved and the ocular pulse waveform became regular in appearance with an OPA of 1.6–2.0 mmHg. The ocular pressure waveform is a direct reflection of hemodynamics. Evaluating this waveform may provide an additional opportunity for screening subjects for cardiovascular anomalies and arrhythmias. |
format | Online Article Text |
id | pubmed-4363960 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-43639602015-03-25 Ocular pressure waveform reflects ventricular bigeminy and aortic insufficiency Kassem, Jean B Katz, Steven E Mahmoud, Ashraf M Small, Robert H Raman, Subha V Roberts, Cynthia J Indian J Ophthalmol Brief Communications Ocular pulse amplitude (OPA) is defined as the difference between maximum and minimum intraocular pressure (IOP) during a cardiac cycle. Average values of OPA range from 1 to 4 mmHg. The purpose of this investigation is to determine the source of an irregular IOP waveform with elevated OPA in a 48-year-old male. Ocular pressure waveforms had an unusual shape consistent with early ventricular contraction. With a normal IOP, OPA was 9 mmHg, which is extraordinarily high. The subject was examined by a cardiologist and was determined to be in ventricular bigeminy. In addition, he had bounding carotid pulses and echocardiogram confirmed aortic insufficiency. After replacement of the aortic valve, the bigeminy resolved and the ocular pulse waveform became regular in appearance with an OPA of 1.6–2.0 mmHg. The ocular pressure waveform is a direct reflection of hemodynamics. Evaluating this waveform may provide an additional opportunity for screening subjects for cardiovascular anomalies and arrhythmias. Medknow Publications & Media Pvt Ltd 2015-01 /pmc/articles/PMC4363960/ /pubmed/25686065 http://dx.doi.org/10.4103/0301-4738.151472 Text en Copyright: © Indian Journal of Ophthalmology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Brief Communications Kassem, Jean B Katz, Steven E Mahmoud, Ashraf M Small, Robert H Raman, Subha V Roberts, Cynthia J Ocular pressure waveform reflects ventricular bigeminy and aortic insufficiency |
title | Ocular pressure waveform reflects ventricular bigeminy and aortic insufficiency |
title_full | Ocular pressure waveform reflects ventricular bigeminy and aortic insufficiency |
title_fullStr | Ocular pressure waveform reflects ventricular bigeminy and aortic insufficiency |
title_full_unstemmed | Ocular pressure waveform reflects ventricular bigeminy and aortic insufficiency |
title_short | Ocular pressure waveform reflects ventricular bigeminy and aortic insufficiency |
title_sort | ocular pressure waveform reflects ventricular bigeminy and aortic insufficiency |
topic | Brief Communications |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4363960/ https://www.ncbi.nlm.nih.gov/pubmed/25686065 http://dx.doi.org/10.4103/0301-4738.151472 |
work_keys_str_mv | AT kassemjeanb ocularpressurewaveformreflectsventricularbigeminyandaorticinsufficiency AT katzstevene ocularpressurewaveformreflectsventricularbigeminyandaorticinsufficiency AT mahmoudashrafm ocularpressurewaveformreflectsventricularbigeminyandaorticinsufficiency AT smallroberth ocularpressurewaveformreflectsventricularbigeminyandaorticinsufficiency AT ramansubhav ocularpressurewaveformreflectsventricularbigeminyandaorticinsufficiency AT robertscynthiaj ocularpressurewaveformreflectsventricularbigeminyandaorticinsufficiency |