Noninvasive Method for Measuring Local Pulse Wave Velocity by Dual Pulse Wave Doppler: In Vitro and In Vivo Studies
OBJECTIVES: To evaluate the validity and reproducibility of a noninvasive dual pulse wave Doppler (DPWD) method, which involves simultaneous recording of flow velocity of two independent sample volumes with a measurable distance, for measuring the local arterial pulse wave velocity (PWV) through in...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4364771/ https://www.ncbi.nlm.nih.gov/pubmed/25786124 http://dx.doi.org/10.1371/journal.pone.0120482 |
_version_ | 1782362125578010624 |
---|---|
author | Wang, Zhen Yang, Yong Yuan, Li-jun Liu, Jie Duan, Yun-you Cao, Tie-sheng |
author_facet | Wang, Zhen Yang, Yong Yuan, Li-jun Liu, Jie Duan, Yun-you Cao, Tie-sheng |
author_sort | Wang, Zhen |
collection | PubMed |
description | OBJECTIVES: To evaluate the validity and reproducibility of a noninvasive dual pulse wave Doppler (DPWD) method, which involves simultaneous recording of flow velocity of two independent sample volumes with a measurable distance, for measuring the local arterial pulse wave velocity (PWV) through in vitro and in vivo studies. METHODS: The DPWD mode of Hitachi HI Vision Preirus ultrasound system with a 5–13MHz transducer was used. An in vitro model was designed to compare the PWV of a homogeneous rubber tubing with the local PWV of its middle part measured by DPWD method. In the in vivo study, local PWV of 45 hypertensive patients (25 male, 49.8±3.1 years) and 45 matched healthy subjects (25 male, 49.3±3.0 years) were investigated at the left common carotid artery (LCCA) by DPWD method. RESULTS: In the in vitro study, the local PWV measured by DPWP method and the PWV of the homogeneous rubber tubing did not show statistical difference (5.16 ± 0.28 m/s vs 5.03 ± 0.15 m/s, p = 0.075). The coefficient of variation (CV) of the intra- and inter- measurements for local PWV were 3.46% and 4.96%, for the PWV of the homogeneous rubber tubing were 0.99% and 1.98%. In the in vivo study, a significantly higher local PWV of LCCA was found in the hypertensive patients as compared to that in healthy subjects (6.29±1.04m/s vs. 5.31±0.72m/s, P = 0.019). The CV of the intra- and inter- measurements in hypertensive patients were 2.22% and 3.94%, in healthy subjects were 2.07% and 4.14%. CONCLUSIONS: This study demonstrated the feasibility of the noninvasive DPWD method to determine the local PWV, which was accurate and reproducible not only in vitro but also in vivo studies. This noninvasive echocardiographic method may be illuminating to clinical use. |
format | Online Article Text |
id | pubmed-4364771 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-43647712015-03-23 Noninvasive Method for Measuring Local Pulse Wave Velocity by Dual Pulse Wave Doppler: In Vitro and In Vivo Studies Wang, Zhen Yang, Yong Yuan, Li-jun Liu, Jie Duan, Yun-you Cao, Tie-sheng PLoS One Research Article OBJECTIVES: To evaluate the validity and reproducibility of a noninvasive dual pulse wave Doppler (DPWD) method, which involves simultaneous recording of flow velocity of two independent sample volumes with a measurable distance, for measuring the local arterial pulse wave velocity (PWV) through in vitro and in vivo studies. METHODS: The DPWD mode of Hitachi HI Vision Preirus ultrasound system with a 5–13MHz transducer was used. An in vitro model was designed to compare the PWV of a homogeneous rubber tubing with the local PWV of its middle part measured by DPWD method. In the in vivo study, local PWV of 45 hypertensive patients (25 male, 49.8±3.1 years) and 45 matched healthy subjects (25 male, 49.3±3.0 years) were investigated at the left common carotid artery (LCCA) by DPWD method. RESULTS: In the in vitro study, the local PWV measured by DPWP method and the PWV of the homogeneous rubber tubing did not show statistical difference (5.16 ± 0.28 m/s vs 5.03 ± 0.15 m/s, p = 0.075). The coefficient of variation (CV) of the intra- and inter- measurements for local PWV were 3.46% and 4.96%, for the PWV of the homogeneous rubber tubing were 0.99% and 1.98%. In the in vivo study, a significantly higher local PWV of LCCA was found in the hypertensive patients as compared to that in healthy subjects (6.29±1.04m/s vs. 5.31±0.72m/s, P = 0.019). The CV of the intra- and inter- measurements in hypertensive patients were 2.22% and 3.94%, in healthy subjects were 2.07% and 4.14%. CONCLUSIONS: This study demonstrated the feasibility of the noninvasive DPWD method to determine the local PWV, which was accurate and reproducible not only in vitro but also in vivo studies. This noninvasive echocardiographic method may be illuminating to clinical use. Public Library of Science 2015-03-18 /pmc/articles/PMC4364771/ /pubmed/25786124 http://dx.doi.org/10.1371/journal.pone.0120482 Text en © 2015 Wang et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Wang, Zhen Yang, Yong Yuan, Li-jun Liu, Jie Duan, Yun-you Cao, Tie-sheng Noninvasive Method for Measuring Local Pulse Wave Velocity by Dual Pulse Wave Doppler: In Vitro and In Vivo Studies |
title | Noninvasive Method for Measuring Local Pulse Wave Velocity by Dual Pulse Wave Doppler: In Vitro and In Vivo Studies |
title_full | Noninvasive Method for Measuring Local Pulse Wave Velocity by Dual Pulse Wave Doppler: In Vitro and In Vivo Studies |
title_fullStr | Noninvasive Method for Measuring Local Pulse Wave Velocity by Dual Pulse Wave Doppler: In Vitro and In Vivo Studies |
title_full_unstemmed | Noninvasive Method for Measuring Local Pulse Wave Velocity by Dual Pulse Wave Doppler: In Vitro and In Vivo Studies |
title_short | Noninvasive Method for Measuring Local Pulse Wave Velocity by Dual Pulse Wave Doppler: In Vitro and In Vivo Studies |
title_sort | noninvasive method for measuring local pulse wave velocity by dual pulse wave doppler: in vitro and in vivo studies |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4364771/ https://www.ncbi.nlm.nih.gov/pubmed/25786124 http://dx.doi.org/10.1371/journal.pone.0120482 |
work_keys_str_mv | AT wangzhen noninvasivemethodformeasuringlocalpulsewavevelocitybydualpulsewavedopplerinvitroandinvivostudies AT yangyong noninvasivemethodformeasuringlocalpulsewavevelocitybydualpulsewavedopplerinvitroandinvivostudies AT yuanlijun noninvasivemethodformeasuringlocalpulsewavevelocitybydualpulsewavedopplerinvitroandinvivostudies AT liujie noninvasivemethodformeasuringlocalpulsewavevelocitybydualpulsewavedopplerinvitroandinvivostudies AT duanyunyou noninvasivemethodformeasuringlocalpulsewavevelocitybydualpulsewavedopplerinvitroandinvivostudies AT caotiesheng noninvasivemethodformeasuringlocalpulsewavevelocitybydualpulsewavedopplerinvitroandinvivostudies |