Cargando…

The Codacs(™) Direct Acoustic Cochlear Implant Actuator: Exploring Alternative Stimulation Sites and Their Stimulation Efficiency

This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is th...

Descripción completa

Detalles Bibliográficos
Autores principales: Grossöhmichen, Martin, Salcher, Rolf, Kreipe, Hans-Heinrich, Lenarz, Thomas, Maier, Hannes
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4364953/
https://www.ncbi.nlm.nih.gov/pubmed/25785860
http://dx.doi.org/10.1371/journal.pone.0119601
_version_ 1782362159620030464
author Grossöhmichen, Martin
Salcher, Rolf
Kreipe, Hans-Heinrich
Lenarz, Thomas
Maier, Hannes
author_facet Grossöhmichen, Martin
Salcher, Rolf
Kreipe, Hans-Heinrich
Lenarz, Thomas
Maier, Hannes
author_sort Grossöhmichen, Martin
collection PubMed
description This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation with a K-piston through a stapes footplate (SFP) fenestration (N = 10) as well as stimulation of the stapes head (SH) with a Bell prosthesis (N = 9), SFP stimulation with an Omega/Aerial prosthesis (N = 8) and reverse RW stimulation (N = 10) were performed in cadaveric human temporal bones (TBs). Codacs actuator output is expressed as equivalent sound pressure level (eq. SPL) using RW and SFP displacement responses, measured by Laser Doppler velocimetry as reference. The axial actuator coupling force in stimulation of stapes and RW was adjusted to ~ 5 mN. The Bell prosthesis and Omega/Aerial prosthesis stimulation generated similar mean eq. SPLs (Bell: 127.5–141.8 eq. dB SPL; Omega/Aerial: 123.6–143.9 eq. dB SPL), being significantly more efficient than K-piston perilymph stimulation (108.6–131.6 eq. dB SPL) and RW stimulation (108.3–128.2 eq. dB SPL). Our results demonstrate that SH, SFP and RW are adequate alternative stimulation sites for the Codacs actuator using coupling prostheses and an axial coupling force of ~ 5 mN. Based on the eq. SPLs, all investigated methods were adequate for in vivo hearing aid applications, provided that experimental conditions including constant coupling force will be implemented.
format Online
Article
Text
id pubmed-4364953
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-43649532015-03-23 The Codacs(™) Direct Acoustic Cochlear Implant Actuator: Exploring Alternative Stimulation Sites and Their Stimulation Efficiency Grossöhmichen, Martin Salcher, Rolf Kreipe, Hans-Heinrich Lenarz, Thomas Maier, Hannes PLoS One Research Article This work assesses the efficiency of the Codacs system actuator (Cochlear Ltd., Sydney Australia) in different inner ear stimulation modalities. Originally the actuator was intended for direct perilymph stimulation after stapedotomy using a piston prosthesis. A possible alternative application is the stimulation of middle ear structures or the round window (RW). Here the perilymph stimulation with a K-piston through a stapes footplate (SFP) fenestration (N = 10) as well as stimulation of the stapes head (SH) with a Bell prosthesis (N = 9), SFP stimulation with an Omega/Aerial prosthesis (N = 8) and reverse RW stimulation (N = 10) were performed in cadaveric human temporal bones (TBs). Codacs actuator output is expressed as equivalent sound pressure level (eq. SPL) using RW and SFP displacement responses, measured by Laser Doppler velocimetry as reference. The axial actuator coupling force in stimulation of stapes and RW was adjusted to ~ 5 mN. The Bell prosthesis and Omega/Aerial prosthesis stimulation generated similar mean eq. SPLs (Bell: 127.5–141.8 eq. dB SPL; Omega/Aerial: 123.6–143.9 eq. dB SPL), being significantly more efficient than K-piston perilymph stimulation (108.6–131.6 eq. dB SPL) and RW stimulation (108.3–128.2 eq. dB SPL). Our results demonstrate that SH, SFP and RW are adequate alternative stimulation sites for the Codacs actuator using coupling prostheses and an axial coupling force of ~ 5 mN. Based on the eq. SPLs, all investigated methods were adequate for in vivo hearing aid applications, provided that experimental conditions including constant coupling force will be implemented. Public Library of Science 2015-03-18 /pmc/articles/PMC4364953/ /pubmed/25785860 http://dx.doi.org/10.1371/journal.pone.0119601 Text en © 2015 Grossöhmichen et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Grossöhmichen, Martin
Salcher, Rolf
Kreipe, Hans-Heinrich
Lenarz, Thomas
Maier, Hannes
The Codacs(™) Direct Acoustic Cochlear Implant Actuator: Exploring Alternative Stimulation Sites and Their Stimulation Efficiency
title The Codacs(™) Direct Acoustic Cochlear Implant Actuator: Exploring Alternative Stimulation Sites and Their Stimulation Efficiency
title_full The Codacs(™) Direct Acoustic Cochlear Implant Actuator: Exploring Alternative Stimulation Sites and Their Stimulation Efficiency
title_fullStr The Codacs(™) Direct Acoustic Cochlear Implant Actuator: Exploring Alternative Stimulation Sites and Their Stimulation Efficiency
title_full_unstemmed The Codacs(™) Direct Acoustic Cochlear Implant Actuator: Exploring Alternative Stimulation Sites and Their Stimulation Efficiency
title_short The Codacs(™) Direct Acoustic Cochlear Implant Actuator: Exploring Alternative Stimulation Sites and Their Stimulation Efficiency
title_sort codacs(™) direct acoustic cochlear implant actuator: exploring alternative stimulation sites and their stimulation efficiency
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4364953/
https://www.ncbi.nlm.nih.gov/pubmed/25785860
http://dx.doi.org/10.1371/journal.pone.0119601
work_keys_str_mv AT grossohmichenmartin thecodacsdirectacousticcochlearimplantactuatorexploringalternativestimulationsitesandtheirstimulationefficiency
AT salcherrolf thecodacsdirectacousticcochlearimplantactuatorexploringalternativestimulationsitesandtheirstimulationefficiency
AT kreipehansheinrich thecodacsdirectacousticcochlearimplantactuatorexploringalternativestimulationsitesandtheirstimulationefficiency
AT lenarzthomas thecodacsdirectacousticcochlearimplantactuatorexploringalternativestimulationsitesandtheirstimulationefficiency
AT maierhannes thecodacsdirectacousticcochlearimplantactuatorexploringalternativestimulationsitesandtheirstimulationefficiency
AT grossohmichenmartin codacsdirectacousticcochlearimplantactuatorexploringalternativestimulationsitesandtheirstimulationefficiency
AT salcherrolf codacsdirectacousticcochlearimplantactuatorexploringalternativestimulationsitesandtheirstimulationefficiency
AT kreipehansheinrich codacsdirectacousticcochlearimplantactuatorexploringalternativestimulationsitesandtheirstimulationefficiency
AT lenarzthomas codacsdirectacousticcochlearimplantactuatorexploringalternativestimulationsitesandtheirstimulationefficiency
AT maierhannes codacsdirectacousticcochlearimplantactuatorexploringalternativestimulationsitesandtheirstimulationefficiency