Cargando…

Kineflex (Centurion) Lumbar Disc Prosthesis: Insertion Technique and 2-Year Clinical Results in 100 Patients

BACKGROUND: The Kineflex lumbar disc is a mechanical, unconstrained, re-centering disc prosthesis developed in South Africa. The first implantation took place in October 2002. We present a single-center, prospective, longitudinal study of the first 100 patients treated with the Kineflex lumbar disc....

Descripción completa

Detalles Bibliográficos
Autores principales: Hähnle, Ulrich R., Weinberg, Ian R., Sliwa, Karen, Sweet, Barry MBE, de Villiers, Malan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: RRY Publications, LLC 2007
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4365569/
https://www.ncbi.nlm.nih.gov/pubmed/25802576
http://dx.doi.org/10.1016/SASJ-2006-0005-RR
_version_ 1782362241497038848
author Hähnle, Ulrich R.
Weinberg, Ian R.
Sliwa, Karen
Sweet, Barry MBE
de Villiers, Malan
author_facet Hähnle, Ulrich R.
Weinberg, Ian R.
Sliwa, Karen
Sweet, Barry MBE
de Villiers, Malan
author_sort Hähnle, Ulrich R.
collection PubMed
description BACKGROUND: The Kineflex lumbar disc is a mechanical, unconstrained, re-centering disc prosthesis developed in South Africa. The first implantation took place in October 2002. We present a single-center, prospective, longitudinal study of the first 100 patients treated with the Kineflex lumbar disc. Our objective was to evaluate the insertion technique, clinical outcomes, and patient satisfaction at 2 years postimplantation in 100 consecutive patients with 132 (68 single- and 32 2-level) Kineflex lumbar disc replacements. METHODS: We determined the exact central placement of all disc implants in the coronal and midsagittal planes. We measured clinical outcome with the Oswestry disability index (ODI), our own questionnaire, and the time needed to return to work. All patients received radiological and clinical follow-up assessments for 2 years after the index procedure. RESULTS: Forty-three patients were female. The mean age of the patients at operation was 44.9 years (range, 23–63 years). Postoperative hospitalization averaged 2.8 days (range, 2 to 8 days). All patients who were employed before surgery returned to work 31 ± 16.8 days after the operation. Fifty-six percent of operated disc levels had intervertebral disc heights of less than 5 mm. A 2-year clinical outcome was available for 98 of the 100 patients (58 excellent, 30 good, 7 fair, 3 poor). The ODI score improved from 47.8 ± 16.0 preoperatively to 14.2 ± 14.0 (P < .01) at 2 years. At 2 years, 95% of disc implants were radiologically in the ideal position. The insertion technique, with a released prosthetic mechanism for final placement, allowed ideal placement in the sagittal plane in 98% of discs. The radiographic placement accuracy achieved was equal in patients with preoperative intervertebral disc height below and above 5 mm. CONCLUSIONS: Good short-term clinical results were achieved with the Kineflex disc in a heterogeneous patient group with a high number of patients with advanced disc degeneration, severe disc space narrowing, and lumbar flat-back deformity. In this cohort, accurate implant placement could be achieved in our first 100 patients. CLINICAL RELEVENCE: This is the first report on the Kineflex mechanical lumbar disc prosthesis.
format Online
Article
Text
id pubmed-4365569
institution National Center for Biotechnology Information
language English
publishDate 2007
publisher RRY Publications, LLC
record_format MEDLINE/PubMed
spelling pubmed-43655692015-03-23 Kineflex (Centurion) Lumbar Disc Prosthesis: Insertion Technique and 2-Year Clinical Results in 100 Patients Hähnle, Ulrich R. Weinberg, Ian R. Sliwa, Karen Sweet, Barry MBE de Villiers, Malan SAS J Full Length Article BACKGROUND: The Kineflex lumbar disc is a mechanical, unconstrained, re-centering disc prosthesis developed in South Africa. The first implantation took place in October 2002. We present a single-center, prospective, longitudinal study of the first 100 patients treated with the Kineflex lumbar disc. Our objective was to evaluate the insertion technique, clinical outcomes, and patient satisfaction at 2 years postimplantation in 100 consecutive patients with 132 (68 single- and 32 2-level) Kineflex lumbar disc replacements. METHODS: We determined the exact central placement of all disc implants in the coronal and midsagittal planes. We measured clinical outcome with the Oswestry disability index (ODI), our own questionnaire, and the time needed to return to work. All patients received radiological and clinical follow-up assessments for 2 years after the index procedure. RESULTS: Forty-three patients were female. The mean age of the patients at operation was 44.9 years (range, 23–63 years). Postoperative hospitalization averaged 2.8 days (range, 2 to 8 days). All patients who were employed before surgery returned to work 31 ± 16.8 days after the operation. Fifty-six percent of operated disc levels had intervertebral disc heights of less than 5 mm. A 2-year clinical outcome was available for 98 of the 100 patients (58 excellent, 30 good, 7 fair, 3 poor). The ODI score improved from 47.8 ± 16.0 preoperatively to 14.2 ± 14.0 (P < .01) at 2 years. At 2 years, 95% of disc implants were radiologically in the ideal position. The insertion technique, with a released prosthetic mechanism for final placement, allowed ideal placement in the sagittal plane in 98% of discs. The radiographic placement accuracy achieved was equal in patients with preoperative intervertebral disc height below and above 5 mm. CONCLUSIONS: Good short-term clinical results were achieved with the Kineflex disc in a heterogeneous patient group with a high number of patients with advanced disc degeneration, severe disc space narrowing, and lumbar flat-back deformity. In this cohort, accurate implant placement could be achieved in our first 100 patients. CLINICAL RELEVENCE: This is the first report on the Kineflex mechanical lumbar disc prosthesis. RRY Publications, LLC 2007-02-01 /pmc/articles/PMC4365569/ /pubmed/25802576 http://dx.doi.org/10.1016/SASJ-2006-0005-RR Text en Copyright SAS - Spine Arthroplasty Society 2007 http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Length Article
Hähnle, Ulrich R.
Weinberg, Ian R.
Sliwa, Karen
Sweet, Barry MBE
de Villiers, Malan
Kineflex (Centurion) Lumbar Disc Prosthesis: Insertion Technique and 2-Year Clinical Results in 100 Patients
title Kineflex (Centurion) Lumbar Disc Prosthesis: Insertion Technique and 2-Year Clinical Results in 100 Patients
title_full Kineflex (Centurion) Lumbar Disc Prosthesis: Insertion Technique and 2-Year Clinical Results in 100 Patients
title_fullStr Kineflex (Centurion) Lumbar Disc Prosthesis: Insertion Technique and 2-Year Clinical Results in 100 Patients
title_full_unstemmed Kineflex (Centurion) Lumbar Disc Prosthesis: Insertion Technique and 2-Year Clinical Results in 100 Patients
title_short Kineflex (Centurion) Lumbar Disc Prosthesis: Insertion Technique and 2-Year Clinical Results in 100 Patients
title_sort kineflex (centurion) lumbar disc prosthesis: insertion technique and 2-year clinical results in 100 patients
topic Full Length Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4365569/
https://www.ncbi.nlm.nih.gov/pubmed/25802576
http://dx.doi.org/10.1016/SASJ-2006-0005-RR
work_keys_str_mv AT hahnleulrichr kineflexcenturionlumbardiscprosthesisinsertiontechniqueand2yearclinicalresultsin100patients
AT weinbergianr kineflexcenturionlumbardiscprosthesisinsertiontechniqueand2yearclinicalresultsin100patients
AT sliwakaren kineflexcenturionlumbardiscprosthesisinsertiontechniqueand2yearclinicalresultsin100patients
AT sweetbarrymbe kineflexcenturionlumbardiscprosthesisinsertiontechniqueand2yearclinicalresultsin100patients
AT devilliersmalan kineflexcenturionlumbardiscprosthesisinsertiontechniqueand2yearclinicalresultsin100patients