Cargando…

Use of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion

BACKGROUND: A quantitative screw accuracy system is proposed that allows for high-fidelity discrimination between various methods of pedicle screw insertion. Our purpose was to study the utility of a quantitative screw accuracy scoring system to assess new imaging technologies and their effects on t...

Descripción completa

Detalles Bibliográficos
Autores principales: Sclafani, Joseph A., Regev, Gilad J., Webb, Jonathan, Garfin, Steven R., Kim, Choll W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Society for the Advancement of Spine Surgery 2011
Materias:
Mis
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4365628/
https://www.ncbi.nlm.nih.gov/pubmed/25802669
http://dx.doi.org/10.1016/j.esas.2011.04.001
_version_ 1782362255116992512
author Sclafani, Joseph A.
Regev, Gilad J.
Webb, Jonathan
Garfin, Steven R.
Kim, Choll W.
author_facet Sclafani, Joseph A.
Regev, Gilad J.
Webb, Jonathan
Garfin, Steven R.
Kim, Choll W.
author_sort Sclafani, Joseph A.
collection PubMed
description BACKGROUND: A quantitative screw accuracy system is proposed that allows for high-fidelity discrimination between various methods of pedicle screw insertion. Our purpose was to study the utility of a quantitative screw accuracy scoring system to assess new imaging technologies and their effects on the minimally invasive spine learning curve. METHODS: By use of a hypothetical “perfect screw,” a scoring system is proposed that may be used to compare the position of a small number of screws inserted according to a desired optimal position. This study incorporates a retrospective review of imaging studies for 10 patients who underwent percutaneous pedicle screw placement with either navigation-assisted O-arm imaging or navigation-assisted C-arm imaging. For the learning-curve portion of the study, 2 cadaveric adult torsos were used for instrumentation. Computed tomography imaging studies were used in both studies to assess screw position in the pedicle and vertebral body in relation to an optimal screw by use of a quantitative scoring system to rate accuracy. RESULTS: The quantitative scoring system allowed a statistically significant accuracy difference to be ascertained between 2 different technologies using fewer data points than previously published methods. When this screw scoring system is applied to minimally invasive percutaneous pedicle screw insertion, an optimal screw position can be achieved with greater accuracy through navigation-assisted technology (O-arm with computer-assisted navigation). When the O-arm with computer-assisted navigation was used by a novice surgeon learning the technique of percutaneous screw insertion, screws were inserted in a shorter period without loss of accuracy. In contrast, use of the traditional C-arm fluoroscopy leads to a loss of accuracy with faster insertion times. Increased accuracy can be seen clinically when compared with fluoroscopic navigation. CONCLUSIONS: The use of a quantitative scoring system allows for rapid assessment of screw accuracy. As additional technologies and new teaching techniques for pedicle screw insertion are developed, this scoring system may be useful as an early assessment tool.
format Online
Article
Text
id pubmed-4365628
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher International Society for the Advancement of Spine Surgery
record_format MEDLINE/PubMed
spelling pubmed-43656282015-03-23 Use of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion Sclafani, Joseph A. Regev, Gilad J. Webb, Jonathan Garfin, Steven R. Kim, Choll W. SAS J Mis BACKGROUND: A quantitative screw accuracy system is proposed that allows for high-fidelity discrimination between various methods of pedicle screw insertion. Our purpose was to study the utility of a quantitative screw accuracy scoring system to assess new imaging technologies and their effects on the minimally invasive spine learning curve. METHODS: By use of a hypothetical “perfect screw,” a scoring system is proposed that may be used to compare the position of a small number of screws inserted according to a desired optimal position. This study incorporates a retrospective review of imaging studies for 10 patients who underwent percutaneous pedicle screw placement with either navigation-assisted O-arm imaging or navigation-assisted C-arm imaging. For the learning-curve portion of the study, 2 cadaveric adult torsos were used for instrumentation. Computed tomography imaging studies were used in both studies to assess screw position in the pedicle and vertebral body in relation to an optimal screw by use of a quantitative scoring system to rate accuracy. RESULTS: The quantitative scoring system allowed a statistically significant accuracy difference to be ascertained between 2 different technologies using fewer data points than previously published methods. When this screw scoring system is applied to minimally invasive percutaneous pedicle screw insertion, an optimal screw position can be achieved with greater accuracy through navigation-assisted technology (O-arm with computer-assisted navigation). When the O-arm with computer-assisted navigation was used by a novice surgeon learning the technique of percutaneous screw insertion, screws were inserted in a shorter period without loss of accuracy. In contrast, use of the traditional C-arm fluoroscopy leads to a loss of accuracy with faster insertion times. Increased accuracy can be seen clinically when compared with fluoroscopic navigation. CONCLUSIONS: The use of a quantitative scoring system allows for rapid assessment of screw accuracy. As additional technologies and new teaching techniques for pedicle screw insertion are developed, this scoring system may be useful as an early assessment tool. International Society for the Advancement of Spine Surgery 2011-09-01 /pmc/articles/PMC4365628/ /pubmed/25802669 http://dx.doi.org/10.1016/j.esas.2011.04.001 Text en © 2011 SAS - The International Society for the Advancement of Spine Surgery. Published by Elsevier Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Mis
Sclafani, Joseph A.
Regev, Gilad J.
Webb, Jonathan
Garfin, Steven R.
Kim, Choll W.
Use of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion
title Use of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion
title_full Use of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion
title_fullStr Use of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion
title_full_unstemmed Use of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion
title_short Use of a quantitative pedicle screw accuracy system to assess new technology: Initial studies on O-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion
title_sort use of a quantitative pedicle screw accuracy system to assess new technology: initial studies on o-arm navigation and its effect on the learning curve of percutaneous pedicle screw insertion
topic Mis
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4365628/
https://www.ncbi.nlm.nih.gov/pubmed/25802669
http://dx.doi.org/10.1016/j.esas.2011.04.001
work_keys_str_mv AT sclafanijosepha useofaquantitativepediclescrewaccuracysystemtoassessnewtechnologyinitialstudiesonoarmnavigationanditseffectonthelearningcurveofpercutaneouspediclescrewinsertion
AT regevgiladj useofaquantitativepediclescrewaccuracysystemtoassessnewtechnologyinitialstudiesonoarmnavigationanditseffectonthelearningcurveofpercutaneouspediclescrewinsertion
AT webbjonathan useofaquantitativepediclescrewaccuracysystemtoassessnewtechnologyinitialstudiesonoarmnavigationanditseffectonthelearningcurveofpercutaneouspediclescrewinsertion
AT garfinstevenr useofaquantitativepediclescrewaccuracysystemtoassessnewtechnologyinitialstudiesonoarmnavigationanditseffectonthelearningcurveofpercutaneouspediclescrewinsertion
AT kimchollw useofaquantitativepediclescrewaccuracysystemtoassessnewtechnologyinitialstudiesonoarmnavigationanditseffectonthelearningcurveofpercutaneouspediclescrewinsertion