Cargando…

Kineflex lumbar artificial disc versus Charité lumbar total disc replacement for the treatment of degenerative disc disease: A randomized non-inferiority trial with minimum of 2 years’ follow-up

BACKGROUND: The Kineflex lumbar artificial disc replacement device (SpinalMotion, Mountain View, California) is a semiconstrained, posterior center of rotation, metal-on-metal intervertebral disc prosthesis. We performed a prospective, randomized, non-inferiority trial comparing the Kineflex Disc wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Pettine, Kenneth, Hersh, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Society for the Advancement of Spine Surgery 2011
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4365632/
https://www.ncbi.nlm.nih.gov/pubmed/25802676
http://dx.doi.org/10.1016/j.esas.2011.07.003
_version_ 1782362256022962176
author Pettine, Kenneth
Hersh, Andrew
author_facet Pettine, Kenneth
Hersh, Andrew
author_sort Pettine, Kenneth
collection PubMed
description BACKGROUND: The Kineflex lumbar artificial disc replacement device (SpinalMotion, Mountain View, California) is a semiconstrained, posterior center of rotation, metal-on-metal intervertebral disc prosthesis. We performed a prospective, randomized, non-inferiority trial comparing the Kineflex Disc with the Food and Drug Administration (FDA)–approved Charité device (DePuy Spine, Raynham, Massachusetts). Our objective was to evaluate the Kineflex Disc's safety and efficacy using validated outcomes measures—the visual analog scale (VAS) and the Oswestry Disability Index (ODI). METHODS: Sixty-four patients were randomized to receive either the Kineflex Disc or Charité device and were then followed up for up to 3 years. Patients completed VAS and ODI questionnaires and were evaluated clinically and radiologically for complication or device failure. Results were analyzed in terms of change in mean VAS score and ODI from baseline, as well as with a comparison of clinical success as defined by FDA investigational device exemption criteria. Non-inferiority was defined as a difference of less than 18 points in the VAS score and difference of less than 10 units on the ODI scale, in keeping with a previously established minimum clinically important difference. RESULTS: The mean improvement for the Kineflex Disc group at 24 months was 56.80 for the VAS score and 37.30 for the ODI. Similarly, the mean improvement in the Charité group was 54.43 for the VAS score and 38.40 for the ODI. At 2 years of follow-up, no difference was found in VAS scores between the two groups. The Kineflex Disc group was therefore found to be non-inferior (mean difference, 2.37; 95% confidence interval, −12.5 to 17.3; P = .004). In addition, at 24 months, 83% of patients in the Kineflex Disc group and 85% of patients in the Charité group met FDA-defined criteria for clinical success, with no difference between groups (P = .802). CONCLUSIONS: This level I evidence shows the Kineflex Disc to be non-inferior to the Charité device in terms of pain reduction (VAS score) and FDA-defined clinical success at 24 months’ follow-up. Both devices showed a high degree of safety.
format Online
Article
Text
id pubmed-4365632
institution National Center for Biotechnology Information
language English
publishDate 2011
publisher International Society for the Advancement of Spine Surgery
record_format MEDLINE/PubMed
spelling pubmed-43656322015-03-23 Kineflex lumbar artificial disc versus Charité lumbar total disc replacement for the treatment of degenerative disc disease: A randomized non-inferiority trial with minimum of 2 years’ follow-up Pettine, Kenneth Hersh, Andrew SAS J Full Length Article BACKGROUND: The Kineflex lumbar artificial disc replacement device (SpinalMotion, Mountain View, California) is a semiconstrained, posterior center of rotation, metal-on-metal intervertebral disc prosthesis. We performed a prospective, randomized, non-inferiority trial comparing the Kineflex Disc with the Food and Drug Administration (FDA)–approved Charité device (DePuy Spine, Raynham, Massachusetts). Our objective was to evaluate the Kineflex Disc's safety and efficacy using validated outcomes measures—the visual analog scale (VAS) and the Oswestry Disability Index (ODI). METHODS: Sixty-four patients were randomized to receive either the Kineflex Disc or Charité device and were then followed up for up to 3 years. Patients completed VAS and ODI questionnaires and were evaluated clinically and radiologically for complication or device failure. Results were analyzed in terms of change in mean VAS score and ODI from baseline, as well as with a comparison of clinical success as defined by FDA investigational device exemption criteria. Non-inferiority was defined as a difference of less than 18 points in the VAS score and difference of less than 10 units on the ODI scale, in keeping with a previously established minimum clinically important difference. RESULTS: The mean improvement for the Kineflex Disc group at 24 months was 56.80 for the VAS score and 37.30 for the ODI. Similarly, the mean improvement in the Charité group was 54.43 for the VAS score and 38.40 for the ODI. At 2 years of follow-up, no difference was found in VAS scores between the two groups. The Kineflex Disc group was therefore found to be non-inferior (mean difference, 2.37; 95% confidence interval, −12.5 to 17.3; P = .004). In addition, at 24 months, 83% of patients in the Kineflex Disc group and 85% of patients in the Charité group met FDA-defined criteria for clinical success, with no difference between groups (P = .802). CONCLUSIONS: This level I evidence shows the Kineflex Disc to be non-inferior to the Charité device in terms of pain reduction (VAS score) and FDA-defined clinical success at 24 months’ follow-up. Both devices showed a high degree of safety. International Society for the Advancement of Spine Surgery 2011-12-01 /pmc/articles/PMC4365632/ /pubmed/25802676 http://dx.doi.org/10.1016/j.esas.2011.07.003 Text en © 2011 SAS - The International Society for the Advancement of Spine Surgery. Published by Elsevier Inc. All rights reserved. http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Full Length Article
Pettine, Kenneth
Hersh, Andrew
Kineflex lumbar artificial disc versus Charité lumbar total disc replacement for the treatment of degenerative disc disease: A randomized non-inferiority trial with minimum of 2 years’ follow-up
title Kineflex lumbar artificial disc versus Charité lumbar total disc replacement for the treatment of degenerative disc disease: A randomized non-inferiority trial with minimum of 2 years’ follow-up
title_full Kineflex lumbar artificial disc versus Charité lumbar total disc replacement for the treatment of degenerative disc disease: A randomized non-inferiority trial with minimum of 2 years’ follow-up
title_fullStr Kineflex lumbar artificial disc versus Charité lumbar total disc replacement for the treatment of degenerative disc disease: A randomized non-inferiority trial with minimum of 2 years’ follow-up
title_full_unstemmed Kineflex lumbar artificial disc versus Charité lumbar total disc replacement for the treatment of degenerative disc disease: A randomized non-inferiority trial with minimum of 2 years’ follow-up
title_short Kineflex lumbar artificial disc versus Charité lumbar total disc replacement for the treatment of degenerative disc disease: A randomized non-inferiority trial with minimum of 2 years’ follow-up
title_sort kineflex lumbar artificial disc versus charité lumbar total disc replacement for the treatment of degenerative disc disease: a randomized non-inferiority trial with minimum of 2 years’ follow-up
topic Full Length Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4365632/
https://www.ncbi.nlm.nih.gov/pubmed/25802676
http://dx.doi.org/10.1016/j.esas.2011.07.003
work_keys_str_mv AT pettinekenneth kineflexlumbarartificialdiscversuscharitelumbartotaldiscreplacementforthetreatmentofdegenerativediscdiseasearandomizednoninferioritytrialwithminimumof2yearsfollowup
AT hershandrew kineflexlumbarartificialdiscversuscharitelumbartotaldiscreplacementforthetreatmentofdegenerativediscdiseasearandomizednoninferioritytrialwithminimumof2yearsfollowup