Step Detection and Activity Recognition Accuracy of Seven Physical Activity Monitors

The aim of this study was to compare the seven following commercially available activity monitors in terms of step count detection accuracy: Movemonitor (Mc Roberts), Up (Jawbone), One (Fitbit), ActivPAL (PAL Technologies Ltd.), Nike+ Fuelband (Nike Inc.), Tractivity (Kineteks Corp.) and Sensewear A...

Descripción completa

Detalles Bibliográficos
Autores principales: Storm, Fabio A., Heller, Ben W., Mazzà, Claudia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4366111/
https://www.ncbi.nlm.nih.gov/pubmed/25789630
http://dx.doi.org/10.1371/journal.pone.0118723
_version_ 1782362318682718208
author Storm, Fabio A.
Heller, Ben W.
Mazzà, Claudia
author_facet Storm, Fabio A.
Heller, Ben W.
Mazzà, Claudia
author_sort Storm, Fabio A.
collection PubMed
description The aim of this study was to compare the seven following commercially available activity monitors in terms of step count detection accuracy: Movemonitor (Mc Roberts), Up (Jawbone), One (Fitbit), ActivPAL (PAL Technologies Ltd.), Nike+ Fuelband (Nike Inc.), Tractivity (Kineteks Corp.) and Sensewear Armband Mini (Bodymedia). Sixteen healthy adults consented to take part in the study. The experimental protocol included walking along an indoor straight walkway, descending and ascending 24 steps, free outdoor walking and free indoor walking. These tasks were repeated at three self-selected walking speeds. Angular velocity signals collected at both shanks using two wireless inertial measurement units (OPAL, ADPM Inc) were used as a reference for the step count, computed using previously validated algorithms. Step detection accuracy was assessed using the mean absolute percentage error computed for each sensor. The Movemonitor and the ActivPAL were also tested within a nine-minute activity recognition protocol, during which the participants performed a set of complex tasks. Posture classifications were obtained from the two monitors and expressed as a percentage of the total task duration. The Movemonitor, One, ActivPAL, Nike+ Fuelband and Sensewear Armband Mini underestimated the number of steps in all the observed walking speeds, whereas the Tractivity significantly overestimated step count. The Movemonitor was the best performing sensor, with an error lower than 2% at all speeds and the smallest error obtained in the outdoor walking. The activity recognition protocol showed that the Movemonitor performed best in the walking recognition, but had difficulty in discriminating between standing and sitting. Results of this study can be used to inform choice of a monitor for specific applications.
format Online
Article
Text
id pubmed-4366111
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-43661112015-03-23 Step Detection and Activity Recognition Accuracy of Seven Physical Activity Monitors Storm, Fabio A. Heller, Ben W. Mazzà, Claudia PLoS One Research Article The aim of this study was to compare the seven following commercially available activity monitors in terms of step count detection accuracy: Movemonitor (Mc Roberts), Up (Jawbone), One (Fitbit), ActivPAL (PAL Technologies Ltd.), Nike+ Fuelband (Nike Inc.), Tractivity (Kineteks Corp.) and Sensewear Armband Mini (Bodymedia). Sixteen healthy adults consented to take part in the study. The experimental protocol included walking along an indoor straight walkway, descending and ascending 24 steps, free outdoor walking and free indoor walking. These tasks were repeated at three self-selected walking speeds. Angular velocity signals collected at both shanks using two wireless inertial measurement units (OPAL, ADPM Inc) were used as a reference for the step count, computed using previously validated algorithms. Step detection accuracy was assessed using the mean absolute percentage error computed for each sensor. The Movemonitor and the ActivPAL were also tested within a nine-minute activity recognition protocol, during which the participants performed a set of complex tasks. Posture classifications were obtained from the two monitors and expressed as a percentage of the total task duration. The Movemonitor, One, ActivPAL, Nike+ Fuelband and Sensewear Armband Mini underestimated the number of steps in all the observed walking speeds, whereas the Tractivity significantly overestimated step count. The Movemonitor was the best performing sensor, with an error lower than 2% at all speeds and the smallest error obtained in the outdoor walking. The activity recognition protocol showed that the Movemonitor performed best in the walking recognition, but had difficulty in discriminating between standing and sitting. Results of this study can be used to inform choice of a monitor for specific applications. Public Library of Science 2015-03-19 /pmc/articles/PMC4366111/ /pubmed/25789630 http://dx.doi.org/10.1371/journal.pone.0118723 Text en © 2015 Storm et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Storm, Fabio A.
Heller, Ben W.
Mazzà, Claudia
Step Detection and Activity Recognition Accuracy of Seven Physical Activity Monitors
title Step Detection and Activity Recognition Accuracy of Seven Physical Activity Monitors
title_full Step Detection and Activity Recognition Accuracy of Seven Physical Activity Monitors
title_fullStr Step Detection and Activity Recognition Accuracy of Seven Physical Activity Monitors
title_full_unstemmed Step Detection and Activity Recognition Accuracy of Seven Physical Activity Monitors
title_short Step Detection and Activity Recognition Accuracy of Seven Physical Activity Monitors
title_sort step detection and activity recognition accuracy of seven physical activity monitors
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4366111/
https://www.ncbi.nlm.nih.gov/pubmed/25789630
http://dx.doi.org/10.1371/journal.pone.0118723
work_keys_str_mv AT stormfabioa stepdetectionandactivityrecognitionaccuracyofsevenphysicalactivitymonitors
AT hellerbenw stepdetectionandactivityrecognitionaccuracyofsevenphysicalactivitymonitors
AT mazzaclaudia stepdetectionandactivityrecognitionaccuracyofsevenphysicalactivitymonitors