Cargando…

Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion

BACKGROUND AND PURPOSE: It has been suggested that CT Perfusion acquisition times <60 seconds are too short to capture the complete in and out-wash of contrast in the tissue, resulting in incomplete time attenuation curves. Yet, these short acquisitions times are not uncommon in clinical practice...

Descripción completa

Detalles Bibliográficos
Autores principales: Borst, Jordi, Marquering, Henk A., Beenen, Ludo F. M., Berkhemer, Olvert A., Dankbaar, Jan Willem, Riordan, Alan J., Majoie, Charles B. L. M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4366202/
https://www.ncbi.nlm.nih.gov/pubmed/25789631
http://dx.doi.org/10.1371/journal.pone.0119409
_version_ 1782362334886363136
author Borst, Jordi
Marquering, Henk A.
Beenen, Ludo F. M.
Berkhemer, Olvert A.
Dankbaar, Jan Willem
Riordan, Alan J.
Majoie, Charles B. L. M.
author_facet Borst, Jordi
Marquering, Henk A.
Beenen, Ludo F. M.
Berkhemer, Olvert A.
Dankbaar, Jan Willem
Riordan, Alan J.
Majoie, Charles B. L. M.
author_sort Borst, Jordi
collection PubMed
description BACKGROUND AND PURPOSE: It has been suggested that CT Perfusion acquisition times <60 seconds are too short to capture the complete in and out-wash of contrast in the tissue, resulting in incomplete time attenuation curves. Yet, these short acquisitions times are not uncommon in clinical practice. The purpose of this study was to investigate the occurrence of time attenuation curve truncation in 48 seconds CT Perfusion acquisition and to quantify its effect on ischemic core and penumbra estimation in patients with acute ischemic stroke due to a proximal intracranial arterial occlusion of the anterior circulation. MATERIALS AND METHODS: We analyzed CT Perfusion data with 48 seconds and extended acquisition times, assuring full time attenuation curves, of 36 patients. Time attenuation curves were classified as complete or truncated. Ischemic core and penumbra volumes resulting from both data sets were compared by median paired differences and interquartile ranges. Controlled experiments were performed using a digital CT Perfusion phantom to investigate the effect of time attenuation curve truncation on ischemic core and penumbra estimation. RESULTS: In 48 seconds acquisition data, truncation was observed in 24 (67%) cases for the time attenuation curves in the ischemic core, in 2 cases for the arterial input function and in 5 cases for the venous output function. Analysis of extended data resulted in smaller ischemic cores and larger penumbras with a median difference of 13.2 (IQR: 4.3–26.0)ml (P<0.001) and; 12.4 (IQR: 4.1–25.7)ml (P<0.001), respectively. The phantom data showed increasing ischemic core overestimation with increasing tissue time attenuation curve truncation. CONCLUSIONS: Truncation is common in patients with large vessel occlusion and results in repartitioning of the area of hypoperfusion into larger ischemic core and smaller penumbra estimations. Phantom experiments confirmed that truncation results in overestimation of the ischemic core.
format Online
Article
Text
id pubmed-4366202
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-43662022015-03-23 Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion Borst, Jordi Marquering, Henk A. Beenen, Ludo F. M. Berkhemer, Olvert A. Dankbaar, Jan Willem Riordan, Alan J. Majoie, Charles B. L. M. PLoS One Research Article BACKGROUND AND PURPOSE: It has been suggested that CT Perfusion acquisition times <60 seconds are too short to capture the complete in and out-wash of contrast in the tissue, resulting in incomplete time attenuation curves. Yet, these short acquisitions times are not uncommon in clinical practice. The purpose of this study was to investigate the occurrence of time attenuation curve truncation in 48 seconds CT Perfusion acquisition and to quantify its effect on ischemic core and penumbra estimation in patients with acute ischemic stroke due to a proximal intracranial arterial occlusion of the anterior circulation. MATERIALS AND METHODS: We analyzed CT Perfusion data with 48 seconds and extended acquisition times, assuring full time attenuation curves, of 36 patients. Time attenuation curves were classified as complete or truncated. Ischemic core and penumbra volumes resulting from both data sets were compared by median paired differences and interquartile ranges. Controlled experiments were performed using a digital CT Perfusion phantom to investigate the effect of time attenuation curve truncation on ischemic core and penumbra estimation. RESULTS: In 48 seconds acquisition data, truncation was observed in 24 (67%) cases for the time attenuation curves in the ischemic core, in 2 cases for the arterial input function and in 5 cases for the venous output function. Analysis of extended data resulted in smaller ischemic cores and larger penumbras with a median difference of 13.2 (IQR: 4.3–26.0)ml (P<0.001) and; 12.4 (IQR: 4.1–25.7)ml (P<0.001), respectively. The phantom data showed increasing ischemic core overestimation with increasing tissue time attenuation curve truncation. CONCLUSIONS: Truncation is common in patients with large vessel occlusion and results in repartitioning of the area of hypoperfusion into larger ischemic core and smaller penumbra estimations. Phantom experiments confirmed that truncation results in overestimation of the ischemic core. Public Library of Science 2015-03-19 /pmc/articles/PMC4366202/ /pubmed/25789631 http://dx.doi.org/10.1371/journal.pone.0119409 Text en © 2015 Borst et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Borst, Jordi
Marquering, Henk A.
Beenen, Ludo F. M.
Berkhemer, Olvert A.
Dankbaar, Jan Willem
Riordan, Alan J.
Majoie, Charles B. L. M.
Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion
title Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion
title_full Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion
title_fullStr Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion
title_full_unstemmed Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion
title_short Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion
title_sort effect of extended ct perfusion acquisition time on ischemic core and penumbra volume estimation in patients with acute ischemic stroke due to a large vessel occlusion
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4366202/
https://www.ncbi.nlm.nih.gov/pubmed/25789631
http://dx.doi.org/10.1371/journal.pone.0119409
work_keys_str_mv AT borstjordi effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion
AT marqueringhenka effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion
AT beenenludofm effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion
AT berkhemerolverta effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion
AT dankbaarjanwillem effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion
AT riordanalanj effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion
AT majoiecharlesblm effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion
AT effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion