Cargando…
Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion
BACKGROUND AND PURPOSE: It has been suggested that CT Perfusion acquisition times <60 seconds are too short to capture the complete in and out-wash of contrast in the tissue, resulting in incomplete time attenuation curves. Yet, these short acquisitions times are not uncommon in clinical practice...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4366202/ https://www.ncbi.nlm.nih.gov/pubmed/25789631 http://dx.doi.org/10.1371/journal.pone.0119409 |
_version_ | 1782362334886363136 |
---|---|
author | Borst, Jordi Marquering, Henk A. Beenen, Ludo F. M. Berkhemer, Olvert A. Dankbaar, Jan Willem Riordan, Alan J. Majoie, Charles B. L. M. |
author_facet | Borst, Jordi Marquering, Henk A. Beenen, Ludo F. M. Berkhemer, Olvert A. Dankbaar, Jan Willem Riordan, Alan J. Majoie, Charles B. L. M. |
author_sort | Borst, Jordi |
collection | PubMed |
description | BACKGROUND AND PURPOSE: It has been suggested that CT Perfusion acquisition times <60 seconds are too short to capture the complete in and out-wash of contrast in the tissue, resulting in incomplete time attenuation curves. Yet, these short acquisitions times are not uncommon in clinical practice. The purpose of this study was to investigate the occurrence of time attenuation curve truncation in 48 seconds CT Perfusion acquisition and to quantify its effect on ischemic core and penumbra estimation in patients with acute ischemic stroke due to a proximal intracranial arterial occlusion of the anterior circulation. MATERIALS AND METHODS: We analyzed CT Perfusion data with 48 seconds and extended acquisition times, assuring full time attenuation curves, of 36 patients. Time attenuation curves were classified as complete or truncated. Ischemic core and penumbra volumes resulting from both data sets were compared by median paired differences and interquartile ranges. Controlled experiments were performed using a digital CT Perfusion phantom to investigate the effect of time attenuation curve truncation on ischemic core and penumbra estimation. RESULTS: In 48 seconds acquisition data, truncation was observed in 24 (67%) cases for the time attenuation curves in the ischemic core, in 2 cases for the arterial input function and in 5 cases for the venous output function. Analysis of extended data resulted in smaller ischemic cores and larger penumbras with a median difference of 13.2 (IQR: 4.3–26.0)ml (P<0.001) and; 12.4 (IQR: 4.1–25.7)ml (P<0.001), respectively. The phantom data showed increasing ischemic core overestimation with increasing tissue time attenuation curve truncation. CONCLUSIONS: Truncation is common in patients with large vessel occlusion and results in repartitioning of the area of hypoperfusion into larger ischemic core and smaller penumbra estimations. Phantom experiments confirmed that truncation results in overestimation of the ischemic core. |
format | Online Article Text |
id | pubmed-4366202 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-43662022015-03-23 Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion Borst, Jordi Marquering, Henk A. Beenen, Ludo F. M. Berkhemer, Olvert A. Dankbaar, Jan Willem Riordan, Alan J. Majoie, Charles B. L. M. PLoS One Research Article BACKGROUND AND PURPOSE: It has been suggested that CT Perfusion acquisition times <60 seconds are too short to capture the complete in and out-wash of contrast in the tissue, resulting in incomplete time attenuation curves. Yet, these short acquisitions times are not uncommon in clinical practice. The purpose of this study was to investigate the occurrence of time attenuation curve truncation in 48 seconds CT Perfusion acquisition and to quantify its effect on ischemic core and penumbra estimation in patients with acute ischemic stroke due to a proximal intracranial arterial occlusion of the anterior circulation. MATERIALS AND METHODS: We analyzed CT Perfusion data with 48 seconds and extended acquisition times, assuring full time attenuation curves, of 36 patients. Time attenuation curves were classified as complete or truncated. Ischemic core and penumbra volumes resulting from both data sets were compared by median paired differences and interquartile ranges. Controlled experiments were performed using a digital CT Perfusion phantom to investigate the effect of time attenuation curve truncation on ischemic core and penumbra estimation. RESULTS: In 48 seconds acquisition data, truncation was observed in 24 (67%) cases for the time attenuation curves in the ischemic core, in 2 cases for the arterial input function and in 5 cases for the venous output function. Analysis of extended data resulted in smaller ischemic cores and larger penumbras with a median difference of 13.2 (IQR: 4.3–26.0)ml (P<0.001) and; 12.4 (IQR: 4.1–25.7)ml (P<0.001), respectively. The phantom data showed increasing ischemic core overestimation with increasing tissue time attenuation curve truncation. CONCLUSIONS: Truncation is common in patients with large vessel occlusion and results in repartitioning of the area of hypoperfusion into larger ischemic core and smaller penumbra estimations. Phantom experiments confirmed that truncation results in overestimation of the ischemic core. Public Library of Science 2015-03-19 /pmc/articles/PMC4366202/ /pubmed/25789631 http://dx.doi.org/10.1371/journal.pone.0119409 Text en © 2015 Borst et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Borst, Jordi Marquering, Henk A. Beenen, Ludo F. M. Berkhemer, Olvert A. Dankbaar, Jan Willem Riordan, Alan J. Majoie, Charles B. L. M. Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion |
title | Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion |
title_full | Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion |
title_fullStr | Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion |
title_full_unstemmed | Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion |
title_short | Effect of Extended CT Perfusion Acquisition Time on Ischemic Core and Penumbra Volume Estimation in Patients with Acute Ischemic Stroke due to a Large Vessel Occlusion |
title_sort | effect of extended ct perfusion acquisition time on ischemic core and penumbra volume estimation in patients with acute ischemic stroke due to a large vessel occlusion |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4366202/ https://www.ncbi.nlm.nih.gov/pubmed/25789631 http://dx.doi.org/10.1371/journal.pone.0119409 |
work_keys_str_mv | AT borstjordi effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion AT marqueringhenka effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion AT beenenludofm effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion AT berkhemerolverta effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion AT dankbaarjanwillem effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion AT riordanalanj effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion AT majoiecharlesblm effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion AT effectofextendedctperfusionacquisitiontimeonischemiccoreandpenumbravolumeestimationinpatientswithacuteischemicstrokeduetoalargevesselocclusion |