Measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers

Office devices can release volatile organic compounds (VOCs) partly generated by toners and inks, as well as particles of paper. The aim of the presented study is to identify indoor emissions of volatile halogenated organic compounds into the office workspace environment. Mixtures of organic polluta...

Descripción completa

Detalles Bibliográficos
Autores principales: Kowalska, Joanna, Szewczyńska, Małgorzata, Pośniak, Małgorzata
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4366558/
https://www.ncbi.nlm.nih.gov/pubmed/25323406
http://dx.doi.org/10.1007/s11356-014-3672-3
_version_ 1782362386136563712
author Kowalska, Joanna
Szewczyńska, Małgorzata
Pośniak, Małgorzata
author_facet Kowalska, Joanna
Szewczyńska, Małgorzata
Pośniak, Małgorzata
author_sort Kowalska, Joanna
collection PubMed
description Office devices can release volatile organic compounds (VOCs) partly generated by toners and inks, as well as particles of paper. The aim of the presented study is to identify indoor emissions of volatile halogenated organic compounds into the office workspace environment. Mixtures of organic pollutants emitted by seven office devices, i.e. printers and copiers, were analyzed by taking samples in laboratory conditions during the operation of these appliances. Tests of volatile organic compound emissions from selected office devices were conducted in a simulated environment (test chamber). Samples of VOCs were collected using three-layered thermal desorption tubes. Separation and identification of organic pollutant emissions were made using thermal desorption combined with gas chromatography coupled to mass spectrometry. Test chamber studies indicated that operation of the office printer and copier would contribute to the significant concentration level of VOCs in typical office indoor air. Among the determined volatile halogenated compounds, only chlorinated organic compounds were identified, inter alia: trichloroethylene — carcinogenic — and tetrachloroethylene — possibly carcinogenic to human. The results show that daily exposure of an office worker to chemical factors released by the tested printing and copying units can be variable in terms of concentrations of VOCs. The highest emissions in the test chamber during printing were measured for ethylbenzene up to 41.3 μg m(−3), xylenes up to 40.5 μg m(−3) and in case of halogenated compounds the highest concentration for chlorobenzene was 6.48 μg m(−3). The study included the comparison of chamber concentrations and unit-specific emission rates of selected VOCs and the identified halogenated compounds. The highest amount of total VOCs was emitted while copying with device D and was rated above 1235 μg m(−3) and 8400 μg unit(−1) h(−1) on average. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11356-014-3672-3) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-4366558
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-43665582015-03-26 Measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers Kowalska, Joanna Szewczyńska, Małgorzata Pośniak, Małgorzata Environ Sci Pollut Res Int Research Article Office devices can release volatile organic compounds (VOCs) partly generated by toners and inks, as well as particles of paper. The aim of the presented study is to identify indoor emissions of volatile halogenated organic compounds into the office workspace environment. Mixtures of organic pollutants emitted by seven office devices, i.e. printers and copiers, were analyzed by taking samples in laboratory conditions during the operation of these appliances. Tests of volatile organic compound emissions from selected office devices were conducted in a simulated environment (test chamber). Samples of VOCs were collected using three-layered thermal desorption tubes. Separation and identification of organic pollutant emissions were made using thermal desorption combined with gas chromatography coupled to mass spectrometry. Test chamber studies indicated that operation of the office printer and copier would contribute to the significant concentration level of VOCs in typical office indoor air. Among the determined volatile halogenated compounds, only chlorinated organic compounds were identified, inter alia: trichloroethylene — carcinogenic — and tetrachloroethylene — possibly carcinogenic to human. The results show that daily exposure of an office worker to chemical factors released by the tested printing and copying units can be variable in terms of concentrations of VOCs. The highest emissions in the test chamber during printing were measured for ethylbenzene up to 41.3 μg m(−3), xylenes up to 40.5 μg m(−3) and in case of halogenated compounds the highest concentration for chlorobenzene was 6.48 μg m(−3). The study included the comparison of chamber concentrations and unit-specific emission rates of selected VOCs and the identified halogenated compounds. The highest amount of total VOCs was emitted while copying with device D and was rated above 1235 μg m(−3) and 8400 μg unit(−1) h(−1) on average. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s11356-014-3672-3) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2014-10-18 2015 /pmc/articles/PMC4366558/ /pubmed/25323406 http://dx.doi.org/10.1007/s11356-014-3672-3 Text en © The Author(s) 2014 https://creativecommons.org/licenses/by/4.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Research Article
Kowalska, Joanna
Szewczyńska, Małgorzata
Pośniak, Małgorzata
Measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers
title Measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers
title_full Measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers
title_fullStr Measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers
title_full_unstemmed Measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers
title_short Measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers
title_sort measurements of chlorinated volatile organic compounds emitted from office printers and photocopiers
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4366558/
https://www.ncbi.nlm.nih.gov/pubmed/25323406
http://dx.doi.org/10.1007/s11356-014-3672-3
work_keys_str_mv AT kowalskajoanna measurementsofchlorinatedvolatileorganiccompoundsemittedfromofficeprintersandphotocopiers
AT szewczynskamałgorzata measurementsofchlorinatedvolatileorganiccompoundsemittedfromofficeprintersandphotocopiers
AT posniakmałgorzata measurementsofchlorinatedvolatileorganiccompoundsemittedfromofficeprintersandphotocopiers