Cargando…
Retrospective Analysis of the One-per-Million Tumescent Technique in Post-Burn Hand Deformity Surgeries
BACKGROUND: The use of a tourniquet in hand surgery is generally accepted as necessary to create a clear visualization of the operative field. This study aims to determine the effectiveness of one-per-million tumescent solution (1:1,000,000 epinephrine concentration) in creating a bloodless operativ...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Plastic and Reconstructive Surgeons
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4366697/ https://www.ncbi.nlm.nih.gov/pubmed/25798387 http://dx.doi.org/10.5999/aps.2015.42.2.164 |
_version_ | 1782362403021783040 |
---|---|
author | Prasetyono, Theddeus OH Koswara, Astrid Felicia |
author_facet | Prasetyono, Theddeus OH Koswara, Astrid Felicia |
author_sort | Prasetyono, Theddeus OH |
collection | PubMed |
description | BACKGROUND: The use of a tourniquet in hand surgery is generally accepted as necessary to create a clear visualization of the operative field. This study aims to determine the effectiveness of one-per-million tumescent solution (1:1,000,000 epinephrine concentration) in creating a bloodless operative field in post-burn hand deformity surgeries performed without a tourniquet. METHODS: This retrospective observational study was conducted on a series of 12 patients with post-burn hand deformities who underwent surgery between February 2013 and January 2014. A total of 29 operative fields were recorded. The one-per-million tumescent solution was used for hemostatis instead of a tourniquet. The clarity of the operative field, volume of solution injected, duration of surgery, scar thickness and density, and functional outcomes at least three months after the surgery were observed. The relationship of scar thickness and density with the clarity of the operative field was analyzed with the chi-square test. RESULTS: Of the 29 operative fields in which the one-per-million tumescent technique was used, 48.2% were totally bloodless, 44.8% had minimal bleeding, and 6.9% had an acceptable level of bleeding. Both scar thickness and density were shown to have a significant relationship with operative field clarity (P<0.05). CONCLUSIONS: The one-per-million tumescent technique is effective in facilitating post-burn hand deformity surgeries involving meticulous, multiple, and lengthy procedures by creating a relatively clear operative field without the use of a tourniquet. Although scar thickness and density are associated with the clarity of the operative field, this technique can be considered safe and effective in creating a clear operative field. |
format | Online Article Text |
id | pubmed-4366697 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society of Plastic and Reconstructive Surgeons |
record_format | MEDLINE/PubMed |
spelling | pubmed-43666972015-03-20 Retrospective Analysis of the One-per-Million Tumescent Technique in Post-Burn Hand Deformity Surgeries Prasetyono, Theddeus OH Koswara, Astrid Felicia Arch Plast Surg Original Article BACKGROUND: The use of a tourniquet in hand surgery is generally accepted as necessary to create a clear visualization of the operative field. This study aims to determine the effectiveness of one-per-million tumescent solution (1:1,000,000 epinephrine concentration) in creating a bloodless operative field in post-burn hand deformity surgeries performed without a tourniquet. METHODS: This retrospective observational study was conducted on a series of 12 patients with post-burn hand deformities who underwent surgery between February 2013 and January 2014. A total of 29 operative fields were recorded. The one-per-million tumescent solution was used for hemostatis instead of a tourniquet. The clarity of the operative field, volume of solution injected, duration of surgery, scar thickness and density, and functional outcomes at least three months after the surgery were observed. The relationship of scar thickness and density with the clarity of the operative field was analyzed with the chi-square test. RESULTS: Of the 29 operative fields in which the one-per-million tumescent technique was used, 48.2% were totally bloodless, 44.8% had minimal bleeding, and 6.9% had an acceptable level of bleeding. Both scar thickness and density were shown to have a significant relationship with operative field clarity (P<0.05). CONCLUSIONS: The one-per-million tumescent technique is effective in facilitating post-burn hand deformity surgeries involving meticulous, multiple, and lengthy procedures by creating a relatively clear operative field without the use of a tourniquet. Although scar thickness and density are associated with the clarity of the operative field, this technique can be considered safe and effective in creating a clear operative field. The Korean Society of Plastic and Reconstructive Surgeons 2015-03 2015-03-16 /pmc/articles/PMC4366697/ /pubmed/25798387 http://dx.doi.org/10.5999/aps.2015.42.2.164 Text en Copyright © 2015 The Korean Society of Plastic and Reconstructive Surgeons http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/), which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Prasetyono, Theddeus OH Koswara, Astrid Felicia Retrospective Analysis of the One-per-Million Tumescent Technique in Post-Burn Hand Deformity Surgeries |
title | Retrospective Analysis of the One-per-Million Tumescent Technique in Post-Burn Hand Deformity Surgeries |
title_full | Retrospective Analysis of the One-per-Million Tumescent Technique in Post-Burn Hand Deformity Surgeries |
title_fullStr | Retrospective Analysis of the One-per-Million Tumescent Technique in Post-Burn Hand Deformity Surgeries |
title_full_unstemmed | Retrospective Analysis of the One-per-Million Tumescent Technique in Post-Burn Hand Deformity Surgeries |
title_short | Retrospective Analysis of the One-per-Million Tumescent Technique in Post-Burn Hand Deformity Surgeries |
title_sort | retrospective analysis of the one-per-million tumescent technique in post-burn hand deformity surgeries |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4366697/ https://www.ncbi.nlm.nih.gov/pubmed/25798387 http://dx.doi.org/10.5999/aps.2015.42.2.164 |
work_keys_str_mv | AT prasetyonotheddeusoh retrospectiveanalysisoftheonepermilliontumescenttechniqueinpostburnhanddeformitysurgeries AT koswaraastridfelicia retrospectiveanalysisoftheonepermilliontumescenttechniqueinpostburnhanddeformitysurgeries |