Cargando…
Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors
BACKGROUND: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. METHODS: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration proce...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Pathologists and the Korean Society for Cytopathology
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4367109/ https://www.ncbi.nlm.nih.gov/pubmed/26148740 http://dx.doi.org/10.4132/jptm.2015.01.03 |
_version_ | 1782362486692904960 |
---|---|
author | Song, In Hye Song, Joon Seon Sung, Chang Ohk Roh, Jong-Lyel Choi, Seung-Ho Nam, Soon Yuhl Kim, Sang Yoon Lee, Jeong Hyun Baek, Jung Hwan Cho, Kyung-Ja |
author_facet | Song, In Hye Song, Joon Seon Sung, Chang Ohk Roh, Jong-Lyel Choi, Seung-Ho Nam, Soon Yuhl Kim, Sang Yoon Lee, Jeong Hyun Baek, Jung Hwan Cho, Kyung-Ja |
author_sort | Song, In Hye |
collection | PubMed |
description | BACKGROUND: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. METHODS: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. RESULTS: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. CONCLUSIONS: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected. |
format | Online Article Text |
id | pubmed-4367109 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | The Korean Society of Pathologists and the Korean Society for Cytopathology |
record_format | MEDLINE/PubMed |
spelling | pubmed-43671092015-03-20 Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors Song, In Hye Song, Joon Seon Sung, Chang Ohk Roh, Jong-Lyel Choi, Seung-Ho Nam, Soon Yuhl Kim, Sang Yoon Lee, Jeong Hyun Baek, Jung Hwan Cho, Kyung-Ja J Pathol Transl Med Original Article BACKGROUND: Core needle biopsy is a relatively new technique used to diagnose salivary gland lesions, and its role in comparison with fine needle aspiration cytology needs to be refined. METHODS: We compared the results of 228 ultrasound-guided core needle biopsy and 371 fine needle aspiration procedures performed on major salivary gland tumors with their postoperative histological diagnoses. RESULTS: Core needle biopsy resulted in significantly higher sensitivity and more accurate tumor subtyping, especially for malignant tumors, than fine needle aspiration. No patient developed major complications after core needle biopsy. CONCLUSIONS: We recommend ultrasoundguided core needle biopsy as the primary diagnostic tool for the preoperative evaluation of patients with salivary gland lesions, especially when malignancy is suspected. The Korean Society of Pathologists and the Korean Society for Cytopathology 2015-03 2015-03-12 /pmc/articles/PMC4367109/ /pubmed/26148740 http://dx.doi.org/10.4132/jptm.2015.01.03 Text en © The Korean Society of Pathologists and the Korean Society for Cytopathology. All rights reserved. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Song, In Hye Song, Joon Seon Sung, Chang Ohk Roh, Jong-Lyel Choi, Seung-Ho Nam, Soon Yuhl Kim, Sang Yoon Lee, Jeong Hyun Baek, Jung Hwan Cho, Kyung-Ja Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors |
title | Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors |
title_full | Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors |
title_fullStr | Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors |
title_full_unstemmed | Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors |
title_short | Accuracy of Core Needle Biopsy Versus Fine Needle Aspiration Cytology for Diagnosing Salivary Gland Tumors |
title_sort | accuracy of core needle biopsy versus fine needle aspiration cytology for diagnosing salivary gland tumors |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4367109/ https://www.ncbi.nlm.nih.gov/pubmed/26148740 http://dx.doi.org/10.4132/jptm.2015.01.03 |
work_keys_str_mv | AT songinhye accuracyofcoreneedlebiopsyversusfineneedleaspirationcytologyfordiagnosingsalivaryglandtumors AT songjoonseon accuracyofcoreneedlebiopsyversusfineneedleaspirationcytologyfordiagnosingsalivaryglandtumors AT sungchangohk accuracyofcoreneedlebiopsyversusfineneedleaspirationcytologyfordiagnosingsalivaryglandtumors AT rohjonglyel accuracyofcoreneedlebiopsyversusfineneedleaspirationcytologyfordiagnosingsalivaryglandtumors AT choiseungho accuracyofcoreneedlebiopsyversusfineneedleaspirationcytologyfordiagnosingsalivaryglandtumors AT namsoonyuhl accuracyofcoreneedlebiopsyversusfineneedleaspirationcytologyfordiagnosingsalivaryglandtumors AT kimsangyoon accuracyofcoreneedlebiopsyversusfineneedleaspirationcytologyfordiagnosingsalivaryglandtumors AT leejeonghyun accuracyofcoreneedlebiopsyversusfineneedleaspirationcytologyfordiagnosingsalivaryglandtumors AT baekjunghwan accuracyofcoreneedlebiopsyversusfineneedleaspirationcytologyfordiagnosingsalivaryglandtumors AT chokyungja accuracyofcoreneedlebiopsyversusfineneedleaspirationcytologyfordiagnosingsalivaryglandtumors |