Comparison of Signal and Gap-Detection Thresholds for Focused and Broad Cochlear Implant Electrode Configurations

Cochlear implant (CI) users usually exhibit marked across-electrode differences in detection thresholds with “focused” modes of stimulation, such as partial-tripolar (pTP) mode. This may reflect differences either in local neural survival or in the distance of the electrodes from the modiolus. To sh...

Descripción completa

Detalles Bibliográficos
Autores principales: Bierer, Julie Arenberg, Deeks, John M., Billig, Alexander J., Carlyon, Robert P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer US 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4368655/
https://www.ncbi.nlm.nih.gov/pubmed/25644786
http://dx.doi.org/10.1007/s10162-015-0507-y
_version_ 1782362657774370816
author Bierer, Julie Arenberg
Deeks, John M.
Billig, Alexander J.
Carlyon, Robert P.
author_facet Bierer, Julie Arenberg
Deeks, John M.
Billig, Alexander J.
Carlyon, Robert P.
author_sort Bierer, Julie Arenberg
collection PubMed
description Cochlear implant (CI) users usually exhibit marked across-electrode differences in detection thresholds with “focused” modes of stimulation, such as partial-tripolar (pTP) mode. This may reflect differences either in local neural survival or in the distance of the electrodes from the modiolus. To shed light on these two explanations, we compared stimulus-detection thresholds and gap-detection thresholds (GDTs) at comfortably loud levels for at least four electrodes in each of ten Advanced Bionics CI users, using 1031-pps pulse trains. The electrodes selected for each user had a wide range of stimulus-detection thresholds in pTP mode. We also measured across-electrode variations in both stimulus-detection and gap-detection tasks in monopolar (MP) mode. Both stimulus-detection and gap-detection thresholds correlated across modes. However, there was no significant correlation between stimulus-detection and gap-detection thresholds in either mode. Hence, gap-detection thresholds likely tap a source of across-electrode variation additional to, or different from, that revealed by stimulus-detection thresholds. Stimulus-detection thresholds were significantly lower for apical than for basal electrodes in both modes; this was only true for gap detection in pTP mode. Finally, although the across-electrode standard deviation in stimulus-detection thresholds was greater in pTP than in MP mode, the reliability of these differences—assessed by dividing the across-electrode standard deviation by the standard deviation across adaptive runs for each electrode—was similar for the two modes; this metric was also similar across modes for gap detection. Hence across-electrode differences can be revealed using clinically available MP stimulation, with a reliability comparable to that observed with focused stimulation.
format Online
Article
Text
id pubmed-4368655
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Springer US
record_format MEDLINE/PubMed
spelling pubmed-43686552015-03-26 Comparison of Signal and Gap-Detection Thresholds for Focused and Broad Cochlear Implant Electrode Configurations Bierer, Julie Arenberg Deeks, John M. Billig, Alexander J. Carlyon, Robert P. J Assoc Res Otolaryngol Research Article Cochlear implant (CI) users usually exhibit marked across-electrode differences in detection thresholds with “focused” modes of stimulation, such as partial-tripolar (pTP) mode. This may reflect differences either in local neural survival or in the distance of the electrodes from the modiolus. To shed light on these two explanations, we compared stimulus-detection thresholds and gap-detection thresholds (GDTs) at comfortably loud levels for at least four electrodes in each of ten Advanced Bionics CI users, using 1031-pps pulse trains. The electrodes selected for each user had a wide range of stimulus-detection thresholds in pTP mode. We also measured across-electrode variations in both stimulus-detection and gap-detection tasks in monopolar (MP) mode. Both stimulus-detection and gap-detection thresholds correlated across modes. However, there was no significant correlation between stimulus-detection and gap-detection thresholds in either mode. Hence, gap-detection thresholds likely tap a source of across-electrode variation additional to, or different from, that revealed by stimulus-detection thresholds. Stimulus-detection thresholds were significantly lower for apical than for basal electrodes in both modes; this was only true for gap detection in pTP mode. Finally, although the across-electrode standard deviation in stimulus-detection thresholds was greater in pTP than in MP mode, the reliability of these differences—assessed by dividing the across-electrode standard deviation by the standard deviation across adaptive runs for each electrode—was similar for the two modes; this metric was also similar across modes for gap detection. Hence across-electrode differences can be revealed using clinically available MP stimulation, with a reliability comparable to that observed with focused stimulation. Springer US 2015-02-03 2015-04 /pmc/articles/PMC4368655/ /pubmed/25644786 http://dx.doi.org/10.1007/s10162-015-0507-y Text en © The Author(s) 2015 https://creativecommons.org/licenses/by/4.0/ Open Access This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
spellingShingle Research Article
Bierer, Julie Arenberg
Deeks, John M.
Billig, Alexander J.
Carlyon, Robert P.
Comparison of Signal and Gap-Detection Thresholds for Focused and Broad Cochlear Implant Electrode Configurations
title Comparison of Signal and Gap-Detection Thresholds for Focused and Broad Cochlear Implant Electrode Configurations
title_full Comparison of Signal and Gap-Detection Thresholds for Focused and Broad Cochlear Implant Electrode Configurations
title_fullStr Comparison of Signal and Gap-Detection Thresholds for Focused and Broad Cochlear Implant Electrode Configurations
title_full_unstemmed Comparison of Signal and Gap-Detection Thresholds for Focused and Broad Cochlear Implant Electrode Configurations
title_short Comparison of Signal and Gap-Detection Thresholds for Focused and Broad Cochlear Implant Electrode Configurations
title_sort comparison of signal and gap-detection thresholds for focused and broad cochlear implant electrode configurations
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4368655/
https://www.ncbi.nlm.nih.gov/pubmed/25644786
http://dx.doi.org/10.1007/s10162-015-0507-y
work_keys_str_mv AT biererjuliearenberg comparisonofsignalandgapdetectionthresholdsforfocusedandbroadcochlearimplantelectrodeconfigurations
AT deeksjohnm comparisonofsignalandgapdetectionthresholdsforfocusedandbroadcochlearimplantelectrodeconfigurations
AT billigalexanderj comparisonofsignalandgapdetectionthresholdsforfocusedandbroadcochlearimplantelectrodeconfigurations
AT carlyonrobertp comparisonofsignalandgapdetectionthresholdsforfocusedandbroadcochlearimplantelectrodeconfigurations