Cargando…

Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks

Retinal prostheses for the treatment of certain forms of blindness are gaining traction in clinical trials around the world with commercial devices currently entering the market. In order to evaluate the safety of these devices, in preclinical studies, reliable techniques are needed. However, the ha...

Descripción completa

Detalles Bibliográficos
Autores principales: Nayagam, David A.X., Durmo, Irfan, McGowan, Ceara, Williams, Richard A., Shepherd, Robert K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MyJove Corporation 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4370214/
https://www.ncbi.nlm.nih.gov/pubmed/25798628
http://dx.doi.org/10.3791/52348
_version_ 1782362847637929984
author Nayagam, David A.X.
Durmo, Irfan
McGowan, Ceara
Williams, Richard A.
Shepherd, Robert K.
author_facet Nayagam, David A.X.
Durmo, Irfan
McGowan, Ceara
Williams, Richard A.
Shepherd, Robert K.
author_sort Nayagam, David A.X.
collection PubMed
description Retinal prostheses for the treatment of certain forms of blindness are gaining traction in clinical trials around the world with commercial devices currently entering the market. In order to evaluate the safety of these devices, in preclinical studies, reliable techniques are needed. However, the hard metal components utilised in some retinal implants are not compatible with traditional histological processes, particularly in consideration for the delicate nature of the surrounding tissue. Here we describe techniques for assessing the health of the eye directly adjacent to a retinal implant secured epiretinally with a metal tack. Retinal prostheses feature electrode arrays in contact with eye tissue. The most commonly used location for implantation is the epiretinal location (posterior chamber of the eye), where the implant is secured to the retina with a metal tack that penetrates all the layers of the eye. Previous methods have not been able to assess the proximal ocular tissue with the tack in situ, due to the inability of traditional histological techniques to cut metal objects. Consequently, it has been difficult to assess localized damage, if present, caused by tack insertion. Therefore, we developed a technique for visualizing the tissue around a retinal tack and implant. We have modified an established technique, used for processing and visualizing hard bony tissue around a cochlear implant, for the soft delicate tissues of the eye. We orientated and embedded the fixed eye tissue, including the implant and retinal tack, in epoxy resin, to stabilise and protect the structure of the sample. Embedded samples were then ground, polished, stained, and imaged under various magnifications at incremental depths through the sample. This technique allowed the reliable assessment of eye tissue integrity and cytoarchitecture adjacent to the metal tack.
format Online
Article
Text
id pubmed-4370214
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher MyJove Corporation
record_format MEDLINE/PubMed
spelling pubmed-43702142015-04-03 Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks Nayagam, David A.X. Durmo, Irfan McGowan, Ceara Williams, Richard A. Shepherd, Robert K. J Vis Exp Medicine Retinal prostheses for the treatment of certain forms of blindness are gaining traction in clinical trials around the world with commercial devices currently entering the market. In order to evaluate the safety of these devices, in preclinical studies, reliable techniques are needed. However, the hard metal components utilised in some retinal implants are not compatible with traditional histological processes, particularly in consideration for the delicate nature of the surrounding tissue. Here we describe techniques for assessing the health of the eye directly adjacent to a retinal implant secured epiretinally with a metal tack. Retinal prostheses feature electrode arrays in contact with eye tissue. The most commonly used location for implantation is the epiretinal location (posterior chamber of the eye), where the implant is secured to the retina with a metal tack that penetrates all the layers of the eye. Previous methods have not been able to assess the proximal ocular tissue with the tack in situ, due to the inability of traditional histological techniques to cut metal objects. Consequently, it has been difficult to assess localized damage, if present, caused by tack insertion. Therefore, we developed a technique for visualizing the tissue around a retinal tack and implant. We have modified an established technique, used for processing and visualizing hard bony tissue around a cochlear implant, for the soft delicate tissues of the eye. We orientated and embedded the fixed eye tissue, including the implant and retinal tack, in epoxy resin, to stabilise and protect the structure of the sample. Embedded samples were then ground, polished, stained, and imaged under various magnifications at incremental depths through the sample. This technique allowed the reliable assessment of eye tissue integrity and cytoarchitecture adjacent to the metal tack. MyJove Corporation 2015-02-14 /pmc/articles/PMC4370214/ /pubmed/25798628 http://dx.doi.org/10.3791/52348 Text en Copyright © 2015, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Medicine
Nayagam, David A.X.
Durmo, Irfan
McGowan, Ceara
Williams, Richard A.
Shepherd, Robert K.
Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
title Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
title_full Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
title_fullStr Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
title_full_unstemmed Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
title_short Techniques for Processing Eyes Implanted with a Retinal Prosthesis for Localized Histopathological Analysis: Part 2 Epiretinal Implants with Retinal Tacks
title_sort techniques for processing eyes implanted with a retinal prosthesis for localized histopathological analysis: part 2 epiretinal implants with retinal tacks
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4370214/
https://www.ncbi.nlm.nih.gov/pubmed/25798628
http://dx.doi.org/10.3791/52348
work_keys_str_mv AT nayagamdavidax techniquesforprocessingeyesimplantedwitharetinalprosthesisforlocalizedhistopathologicalanalysispart2epiretinalimplantswithretinaltacks
AT durmoirfan techniquesforprocessingeyesimplantedwitharetinalprosthesisforlocalizedhistopathologicalanalysispart2epiretinalimplantswithretinaltacks
AT mcgowanceara techniquesforprocessingeyesimplantedwitharetinalprosthesisforlocalizedhistopathologicalanalysispart2epiretinalimplantswithretinaltacks
AT williamsricharda techniquesforprocessingeyesimplantedwitharetinalprosthesisforlocalizedhistopathologicalanalysispart2epiretinalimplantswithretinaltacks
AT shepherdrobertk techniquesforprocessingeyesimplantedwitharetinalprosthesisforlocalizedhistopathologicalanalysispart2epiretinalimplantswithretinaltacks
AT techniquesforprocessingeyesimplantedwitharetinalprosthesisforlocalizedhistopathologicalanalysispart2epiretinalimplantswithretinaltacks