Corneal decompensation following filtering surgery with the Ex-PRESS(®) mini glaucoma shunt device
PURPOSE: To report a case of corneal decompensation due to the Ex-PRESS(®) mini glaucoma shunt device (Ex-PRESS). PATIENT AND METHODS: A 75-year-old man had pseudoexfoliation glaucoma in his right eye. He underwent filtration surgery with Ex-PRESS. His intraocular pressure was 7 mmHg after 9 months....