Cargando…
Multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method
PURPOSE: Noninvasive image-guided breast brachytherapy delivers conformal HDR (192)Ir brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sit...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Termedia Publishing House
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4371066/ https://www.ncbi.nlm.nih.gov/pubmed/25829938 http://dx.doi.org/10.5114/jcb.2015.49355 |
_version_ | 1782362977053179904 |
---|---|
author | Rivard, Mark J. Ghadyani, Hamid R. Bastien, Adam D. Lutz, Nicholas N. Hepel, Jaroslaw T. |
author_facet | Rivard, Mark J. Ghadyani, Hamid R. Bastien, Adam D. Lutz, Nicholas N. Hepel, Jaroslaw T. |
author_sort | Rivard, Mark J. |
collection | PubMed |
description | PURPOSE: Noninvasive image-guided breast brachytherapy delivers conformal HDR (192)Ir brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sites. Given that, commercially-available software for deformable image registration cannot accurately co-register image sets obtained in these two states, a finite element analysis based on a biomechanical model was developed to deform dose distributions for each compression circumstance for dose summation. MATERIAL AND METHODS: The model assumed the breast was under planar stress with values of 30 kPa for Young's modulus and 0.3 for Poisson's ratio. Dose distributions from round and skin-dose optimized applicators in cranial-caudal and medial-lateral compressions were deformed using 0.1 cm planar resolution. Dose distributions, skin doses, and dose-volume histograms were generated. Results were examined as a function of breast thickness, applicator size, target size, and offset distance from the center. RESULTS: Over the range of examined thicknesses, target size increased several millimeters as compression thickness decreased. This trend increased with increasing offset distances. Applicator size minimally affected target coverage, until applicator size was less than the compressed target size. In all cases, with an applicator larger or equal to the compressed target size, > 90% of the target covered by > 90% of the prescription dose. In all cases, dose coverage became less uniform as offset distance increased and average dose increased. This effect was more pronounced for smaller target–applicator combinations. CONCLUSIONS: The model exhibited skin dose trends that matched MC-generated benchmarking results within 2% and clinical observations over a similar range of breast thicknesses and target sizes. The model provided quantitative insight on dosimetric treatment variables over a range of clinical circumstances. These findings highlight the need for careful target localization and accurate identification of compression thickness and target offset. |
format | Online Article Text |
id | pubmed-4371066 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Termedia Publishing House |
record_format | MEDLINE/PubMed |
spelling | pubmed-43710662015-03-31 Multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method Rivard, Mark J. Ghadyani, Hamid R. Bastien, Adam D. Lutz, Nicholas N. Hepel, Jaroslaw T. J Contemp Brachytherapy Original Paper PURPOSE: Noninvasive image-guided breast brachytherapy delivers conformal HDR (192)Ir brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sites. Given that, commercially-available software for deformable image registration cannot accurately co-register image sets obtained in these two states, a finite element analysis based on a biomechanical model was developed to deform dose distributions for each compression circumstance for dose summation. MATERIAL AND METHODS: The model assumed the breast was under planar stress with values of 30 kPa for Young's modulus and 0.3 for Poisson's ratio. Dose distributions from round and skin-dose optimized applicators in cranial-caudal and medial-lateral compressions were deformed using 0.1 cm planar resolution. Dose distributions, skin doses, and dose-volume histograms were generated. Results were examined as a function of breast thickness, applicator size, target size, and offset distance from the center. RESULTS: Over the range of examined thicknesses, target size increased several millimeters as compression thickness decreased. This trend increased with increasing offset distances. Applicator size minimally affected target coverage, until applicator size was less than the compressed target size. In all cases, with an applicator larger or equal to the compressed target size, > 90% of the target covered by > 90% of the prescription dose. In all cases, dose coverage became less uniform as offset distance increased and average dose increased. This effect was more pronounced for smaller target–applicator combinations. CONCLUSIONS: The model exhibited skin dose trends that matched MC-generated benchmarking results within 2% and clinical observations over a similar range of breast thicknesses and target sizes. The model provided quantitative insight on dosimetric treatment variables over a range of clinical circumstances. These findings highlight the need for careful target localization and accurate identification of compression thickness and target offset. Termedia Publishing House 2015-02-17 2015-02 /pmc/articles/PMC4371066/ /pubmed/25829938 http://dx.doi.org/10.5114/jcb.2015.49355 Text en Copyright © 2015 Termedia http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-Noncommercial 3.0 Unported License, permitting all non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Paper Rivard, Mark J. Ghadyani, Hamid R. Bastien, Adam D. Lutz, Nicholas N. Hepel, Jaroslaw T. Multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method |
title | Multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method |
title_full | Multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method |
title_fullStr | Multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method |
title_full_unstemmed | Multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method |
title_short | Multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method |
title_sort | multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4371066/ https://www.ncbi.nlm.nih.gov/pubmed/25829938 http://dx.doi.org/10.5114/jcb.2015.49355 |
work_keys_str_mv | AT rivardmarkj multiaxisdoseaccumulationofnoninvasiveimageguidedbreastbrachytherapythroughbiomechanicalmodelingoftissuedeformationusingthefiniteelementmethod AT ghadyanihamidr multiaxisdoseaccumulationofnoninvasiveimageguidedbreastbrachytherapythroughbiomechanicalmodelingoftissuedeformationusingthefiniteelementmethod AT bastienadamd multiaxisdoseaccumulationofnoninvasiveimageguidedbreastbrachytherapythroughbiomechanicalmodelingoftissuedeformationusingthefiniteelementmethod AT lutznicholasn multiaxisdoseaccumulationofnoninvasiveimageguidedbreastbrachytherapythroughbiomechanicalmodelingoftissuedeformationusingthefiniteelementmethod AT hepeljaroslawt multiaxisdoseaccumulationofnoninvasiveimageguidedbreastbrachytherapythroughbiomechanicalmodelingoftissuedeformationusingthefiniteelementmethod |