Cargando…
The use of strain, strain rate, and displacement by 2D speckle tracking for assessment of systolic left ventricular function in goats: applicability and influence of general anesthesia
BACKGROUND: Assessment of left ventricular (LV) systolic function can be achieved by conventional echocardiographic methods, but quantification of contractility, regional myocardial function, and ventricular synchrony is challenging. The goal of this study was to investigate the applicability of two...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4373510/ https://www.ncbi.nlm.nih.gov/pubmed/25885445 http://dx.doi.org/10.1186/s12947-015-0005-8 |
_version_ | 1782363354602405888 |
---|---|
author | Berli, Ann-Sabin J Jud Schefer, Rahel Steininger, Kathrin Schwarzwald, Colin C |
author_facet | Berli, Ann-Sabin J Jud Schefer, Rahel Steininger, Kathrin Schwarzwald, Colin C |
author_sort | Berli, Ann-Sabin J |
collection | PubMed |
description | BACKGROUND: Assessment of left ventricular (LV) systolic function can be achieved by conventional echocardiographic methods, but quantification of contractility, regional myocardial function, and ventricular synchrony is challenging. The goal of this study was to investigate the applicability of two-dimensional speckle tracking (2DST) to characterize segmental and global wall motion for assessment of LV function and LV synchrony in healthy goats. We aimed to describe the techniques, report normal values of a variety of 2DST indices, and determine the influence of general anesthesia. METHODS: Prospective study on 22 healthy female Saanen goats (3.7 ± 1.1 y, 60.2 ± 10.5 kg [mean ± SD]). All goats underwent two transthoracic echocardiographic examinations, the first standing and unsedated and the second 7.4 ± 3.5 days later during isoflurane anesthesia and positioned in sternal recumbency. Data analyses were performed offline, blinded, and in random order. Left ventricular longitudinal, radial and circumferential strain and strain rate as well as longitudinal and radial displacement were measured using 2DST methods. Summary statistics were generated and differences of 2DST variables between myocardial segments and treatments (i.e., awake vs. anesthetized) were assessed statistically (alpha level=0.05). RESULTS: Echocardiographic analyses by 2DST were feasible in all goats and at both time points. Longitudinal systolic strain, strain rate and displacement followed a gradient from apex to base. Absolute systolic strain was generally lower and strain rate was higher in awake goats compared to anesthetized goats. Circumferential and radial indices did not consistently follow a segmental pattern. Generally, peak strain occurred later in anesthetized goats compared to awake goats. General anesthesia did not significantly influence LV synchrony. CONCLUSIONS: 2SDT is a valid method for non-invasive characterization of LV wall motion in awake and anesthetized goats. The results of this study add to the understanding of LV mechanical function, aid in the diagnosis of global and segmental LV systolic dysfunction, and will be useful for future cardiovascular studies in this species. However, effects of anesthesia and species-specific characteristics should be considered when goats are used as animal models for human disease. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12947-015-0005-8) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-4373510 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-43735102015-03-26 The use of strain, strain rate, and displacement by 2D speckle tracking for assessment of systolic left ventricular function in goats: applicability and influence of general anesthesia Berli, Ann-Sabin J Jud Schefer, Rahel Steininger, Kathrin Schwarzwald, Colin C Cardiovasc Ultrasound Research BACKGROUND: Assessment of left ventricular (LV) systolic function can be achieved by conventional echocardiographic methods, but quantification of contractility, regional myocardial function, and ventricular synchrony is challenging. The goal of this study was to investigate the applicability of two-dimensional speckle tracking (2DST) to characterize segmental and global wall motion for assessment of LV function and LV synchrony in healthy goats. We aimed to describe the techniques, report normal values of a variety of 2DST indices, and determine the influence of general anesthesia. METHODS: Prospective study on 22 healthy female Saanen goats (3.7 ± 1.1 y, 60.2 ± 10.5 kg [mean ± SD]). All goats underwent two transthoracic echocardiographic examinations, the first standing and unsedated and the second 7.4 ± 3.5 days later during isoflurane anesthesia and positioned in sternal recumbency. Data analyses were performed offline, blinded, and in random order. Left ventricular longitudinal, radial and circumferential strain and strain rate as well as longitudinal and radial displacement were measured using 2DST methods. Summary statistics were generated and differences of 2DST variables between myocardial segments and treatments (i.e., awake vs. anesthetized) were assessed statistically (alpha level=0.05). RESULTS: Echocardiographic analyses by 2DST were feasible in all goats and at both time points. Longitudinal systolic strain, strain rate and displacement followed a gradient from apex to base. Absolute systolic strain was generally lower and strain rate was higher in awake goats compared to anesthetized goats. Circumferential and radial indices did not consistently follow a segmental pattern. Generally, peak strain occurred later in anesthetized goats compared to awake goats. General anesthesia did not significantly influence LV synchrony. CONCLUSIONS: 2SDT is a valid method for non-invasive characterization of LV wall motion in awake and anesthetized goats. The results of this study add to the understanding of LV mechanical function, aid in the diagnosis of global and segmental LV systolic dysfunction, and will be useful for future cardiovascular studies in this species. However, effects of anesthesia and species-specific characteristics should be considered when goats are used as animal models for human disease. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s12947-015-0005-8) contains supplementary material, which is available to authorized users. BioMed Central 2015-03-17 /pmc/articles/PMC4373510/ /pubmed/25885445 http://dx.doi.org/10.1186/s12947-015-0005-8 Text en © Berli et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Research Berli, Ann-Sabin J Jud Schefer, Rahel Steininger, Kathrin Schwarzwald, Colin C The use of strain, strain rate, and displacement by 2D speckle tracking for assessment of systolic left ventricular function in goats: applicability and influence of general anesthesia |
title | The use of strain, strain rate, and displacement by 2D speckle tracking for assessment of systolic left ventricular function in goats: applicability and influence of general anesthesia |
title_full | The use of strain, strain rate, and displacement by 2D speckle tracking for assessment of systolic left ventricular function in goats: applicability and influence of general anesthesia |
title_fullStr | The use of strain, strain rate, and displacement by 2D speckle tracking for assessment of systolic left ventricular function in goats: applicability and influence of general anesthesia |
title_full_unstemmed | The use of strain, strain rate, and displacement by 2D speckle tracking for assessment of systolic left ventricular function in goats: applicability and influence of general anesthesia |
title_short | The use of strain, strain rate, and displacement by 2D speckle tracking for assessment of systolic left ventricular function in goats: applicability and influence of general anesthesia |
title_sort | use of strain, strain rate, and displacement by 2d speckle tracking for assessment of systolic left ventricular function in goats: applicability and influence of general anesthesia |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4373510/ https://www.ncbi.nlm.nih.gov/pubmed/25885445 http://dx.doi.org/10.1186/s12947-015-0005-8 |
work_keys_str_mv | AT berliannsabinj theuseofstrainstrainrateanddisplacementby2dspeckletrackingforassessmentofsystolicleftventricularfunctioningoatsapplicabilityandinfluenceofgeneralanesthesia AT judscheferrahel theuseofstrainstrainrateanddisplacementby2dspeckletrackingforassessmentofsystolicleftventricularfunctioningoatsapplicabilityandinfluenceofgeneralanesthesia AT steiningerkathrin theuseofstrainstrainrateanddisplacementby2dspeckletrackingforassessmentofsystolicleftventricularfunctioningoatsapplicabilityandinfluenceofgeneralanesthesia AT schwarzwaldcolinc theuseofstrainstrainrateanddisplacementby2dspeckletrackingforassessmentofsystolicleftventricularfunctioningoatsapplicabilityandinfluenceofgeneralanesthesia AT berliannsabinj useofstrainstrainrateanddisplacementby2dspeckletrackingforassessmentofsystolicleftventricularfunctioningoatsapplicabilityandinfluenceofgeneralanesthesia AT judscheferrahel useofstrainstrainrateanddisplacementby2dspeckletrackingforassessmentofsystolicleftventricularfunctioningoatsapplicabilityandinfluenceofgeneralanesthesia AT steiningerkathrin useofstrainstrainrateanddisplacementby2dspeckletrackingforassessmentofsystolicleftventricularfunctioningoatsapplicabilityandinfluenceofgeneralanesthesia AT schwarzwaldcolinc useofstrainstrainrateanddisplacementby2dspeckletrackingforassessmentofsystolicleftventricularfunctioningoatsapplicabilityandinfluenceofgeneralanesthesia |