Cargando…

Detection of acute traumatic coagulopathy and massive transfusion requirements by means of rotational thromboelastometry: an international prospective validation study

INTRODUCTION: The purpose of this study was to re-evaluate the findings of a smaller cohort study on the functional definition and characteristics of acute traumatic coagulopathy (ATC). We also aimed to identify the threshold values for the most accurate identification of ATC and prediction of massi...

Descripción completa

Detalles Bibliográficos
Autores principales: Hagemo, Jostein S, Christiaans, Sarah C, Stanworth, Simon J, Brohi, Karim, Johansson, Pär I, Goslings, J Carel, Naess, Paal A, Gaarder, Christine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4374411/
https://www.ncbi.nlm.nih.gov/pubmed/25888032
http://dx.doi.org/10.1186/s13054-015-0823-y
_version_ 1782363487361564672
author Hagemo, Jostein S
Christiaans, Sarah C
Stanworth, Simon J
Brohi, Karim
Johansson, Pär I
Goslings, J Carel
Naess, Paal A
Gaarder, Christine
author_facet Hagemo, Jostein S
Christiaans, Sarah C
Stanworth, Simon J
Brohi, Karim
Johansson, Pär I
Goslings, J Carel
Naess, Paal A
Gaarder, Christine
author_sort Hagemo, Jostein S
collection PubMed
description INTRODUCTION: The purpose of this study was to re-evaluate the findings of a smaller cohort study on the functional definition and characteristics of acute traumatic coagulopathy (ATC). We also aimed to identify the threshold values for the most accurate identification of ATC and prediction of massive transfusion (MT) using rotational thromboelastometry (ROTEM) assays. METHODS: In this prospective international multicentre cohort study, adult trauma patients who met the local criteria for full trauma team activation from four major trauma centres were included. Blood was collected on arrival to the emergency department and analyzed with laboratory international normalized ratio (INR), fibrinogen concentration and two ROTEM assays (EXTEM and FIBTEM). ATC was defined as laboratory INR >1.2. Transfusion requirements of ≥10 units of packed red blood cells within 24 hours were defined as MT. Performance of the tests were evaluated by receiver operating characteristic curves, and calculation of area under the curve (AUC). Optimal cutoff points were estimated based on Youden index. RESULTS: In total, 808 patients were included in the study. Among the ROTEM parameters, the largest AUCs were found for the clot amplitude (CA) 5 value in both the EXTEM and FIBTEM assays. EXTEM CA5 threshold value of ≤37 mm had a detection rate of 66.3% for ATC. An EXTEM CA5 threshold value of ≤40 mm predicted MT in 72.7%. FIBTEM CA5 threshold value of ≤8 mm detected ATC in 67.5%, and a FIBTEM CA5 threshold value ≤9 mm predicted MT in 77.5%. Fibrinogen concentration ≤1.6 g/L detected ATC in 73.6% and a fibrinogen concentration ≤1.90 g/L predicted MT in 77.8%. Patients with either an EXTEM or FIBTEM CA5 below the optimum detection threshold for ATC received significantly more packed red blood cells and plasma. CONCLUSIONS: This study confirms previous findings of ROTEM CA5 as a valid marker for ATC and predictor for MT. With optimum threshold for EXTEM CA5 ≤ 40 mm and FIBTEM CA5 ≤ 9 mm, sensitivity is 72.7% and 77.5% respectively. Future investigations should evaluate the role of repeated viscoelastic testing in guiding haemostatic resuscitation in trauma.
format Online
Article
Text
id pubmed-4374411
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-43744112015-03-27 Detection of acute traumatic coagulopathy and massive transfusion requirements by means of rotational thromboelastometry: an international prospective validation study Hagemo, Jostein S Christiaans, Sarah C Stanworth, Simon J Brohi, Karim Johansson, Pär I Goslings, J Carel Naess, Paal A Gaarder, Christine Crit Care Research INTRODUCTION: The purpose of this study was to re-evaluate the findings of a smaller cohort study on the functional definition and characteristics of acute traumatic coagulopathy (ATC). We also aimed to identify the threshold values for the most accurate identification of ATC and prediction of massive transfusion (MT) using rotational thromboelastometry (ROTEM) assays. METHODS: In this prospective international multicentre cohort study, adult trauma patients who met the local criteria for full trauma team activation from four major trauma centres were included. Blood was collected on arrival to the emergency department and analyzed with laboratory international normalized ratio (INR), fibrinogen concentration and two ROTEM assays (EXTEM and FIBTEM). ATC was defined as laboratory INR >1.2. Transfusion requirements of ≥10 units of packed red blood cells within 24 hours were defined as MT. Performance of the tests were evaluated by receiver operating characteristic curves, and calculation of area under the curve (AUC). Optimal cutoff points were estimated based on Youden index. RESULTS: In total, 808 patients were included in the study. Among the ROTEM parameters, the largest AUCs were found for the clot amplitude (CA) 5 value in both the EXTEM and FIBTEM assays. EXTEM CA5 threshold value of ≤37 mm had a detection rate of 66.3% for ATC. An EXTEM CA5 threshold value of ≤40 mm predicted MT in 72.7%. FIBTEM CA5 threshold value of ≤8 mm detected ATC in 67.5%, and a FIBTEM CA5 threshold value ≤9 mm predicted MT in 77.5%. Fibrinogen concentration ≤1.6 g/L detected ATC in 73.6% and a fibrinogen concentration ≤1.90 g/L predicted MT in 77.8%. Patients with either an EXTEM or FIBTEM CA5 below the optimum detection threshold for ATC received significantly more packed red blood cells and plasma. CONCLUSIONS: This study confirms previous findings of ROTEM CA5 as a valid marker for ATC and predictor for MT. With optimum threshold for EXTEM CA5 ≤ 40 mm and FIBTEM CA5 ≤ 9 mm, sensitivity is 72.7% and 77.5% respectively. Future investigations should evaluate the role of repeated viscoelastic testing in guiding haemostatic resuscitation in trauma. BioMed Central 2015-03-23 2015 /pmc/articles/PMC4374411/ /pubmed/25888032 http://dx.doi.org/10.1186/s13054-015-0823-y Text en © Hagemo et al.; licensee BioMed Central. 2015 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Hagemo, Jostein S
Christiaans, Sarah C
Stanworth, Simon J
Brohi, Karim
Johansson, Pär I
Goslings, J Carel
Naess, Paal A
Gaarder, Christine
Detection of acute traumatic coagulopathy and massive transfusion requirements by means of rotational thromboelastometry: an international prospective validation study
title Detection of acute traumatic coagulopathy and massive transfusion requirements by means of rotational thromboelastometry: an international prospective validation study
title_full Detection of acute traumatic coagulopathy and massive transfusion requirements by means of rotational thromboelastometry: an international prospective validation study
title_fullStr Detection of acute traumatic coagulopathy and massive transfusion requirements by means of rotational thromboelastometry: an international prospective validation study
title_full_unstemmed Detection of acute traumatic coagulopathy and massive transfusion requirements by means of rotational thromboelastometry: an international prospective validation study
title_short Detection of acute traumatic coagulopathy and massive transfusion requirements by means of rotational thromboelastometry: an international prospective validation study
title_sort detection of acute traumatic coagulopathy and massive transfusion requirements by means of rotational thromboelastometry: an international prospective validation study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4374411/
https://www.ncbi.nlm.nih.gov/pubmed/25888032
http://dx.doi.org/10.1186/s13054-015-0823-y
work_keys_str_mv AT hagemojosteins detectionofacutetraumaticcoagulopathyandmassivetransfusionrequirementsbymeansofrotationalthromboelastometryaninternationalprospectivevalidationstudy
AT christiaanssarahc detectionofacutetraumaticcoagulopathyandmassivetransfusionrequirementsbymeansofrotationalthromboelastometryaninternationalprospectivevalidationstudy
AT stanworthsimonj detectionofacutetraumaticcoagulopathyandmassivetransfusionrequirementsbymeansofrotationalthromboelastometryaninternationalprospectivevalidationstudy
AT brohikarim detectionofacutetraumaticcoagulopathyandmassivetransfusionrequirementsbymeansofrotationalthromboelastometryaninternationalprospectivevalidationstudy
AT johanssonpari detectionofacutetraumaticcoagulopathyandmassivetransfusionrequirementsbymeansofrotationalthromboelastometryaninternationalprospectivevalidationstudy
AT goslingsjcarel detectionofacutetraumaticcoagulopathyandmassivetransfusionrequirementsbymeansofrotationalthromboelastometryaninternationalprospectivevalidationstudy
AT naesspaala detectionofacutetraumaticcoagulopathyandmassivetransfusionrequirementsbymeansofrotationalthromboelastometryaninternationalprospectivevalidationstudy
AT gaarderchristine detectionofacutetraumaticcoagulopathyandmassivetransfusionrequirementsbymeansofrotationalthromboelastometryaninternationalprospectivevalidationstudy