Cargando…

Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time

BACKGROUND: Interest in 3D inertial motion tracking devices (AHRS) has been growing rapidly among the biomechanical community. Although the convenience of such tracking devices seems to open a whole new world of possibilities for evaluation in clinical biomechanics, its limitations haven’t been exte...

Descripción completa

Detalles Bibliográficos
Autores principales: Lebel, Karina, Boissy, Patrick, Hamel, Mathieu, Duval, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4374941/
https://www.ncbi.nlm.nih.gov/pubmed/25811838
http://dx.doi.org/10.1371/journal.pone.0118361
_version_ 1782363575238524928
author Lebel, Karina
Boissy, Patrick
Hamel, Mathieu
Duval, Christian
author_facet Lebel, Karina
Boissy, Patrick
Hamel, Mathieu
Duval, Christian
author_sort Lebel, Karina
collection PubMed
description BACKGROUND: Interest in 3D inertial motion tracking devices (AHRS) has been growing rapidly among the biomechanical community. Although the convenience of such tracking devices seems to open a whole new world of possibilities for evaluation in clinical biomechanics, its limitations haven’t been extensively documented. The objectives of this study are: 1) to assess the change in absolute and relative accuracy of multiple units of 3 commercially available AHRS over time; and 2) to identify different sources of errors affecting AHRS accuracy and to document how they may affect the measurements over time. METHODS: This study used an instrumented Gimbal table on which AHRS modules were carefully attached and put through a series of velocity-controlled sustained motions including 2 minutes motion trials (2MT) and 12 minutes multiple dynamic phases motion trials (12MDP). Absolute accuracy was assessed by comparison of the AHRS orientation measurements to those of an optical gold standard. Relative accuracy was evaluated using the variation in relative orientation between modules during the trials. FINDINGS: Both absolute and relative accuracy decreased over time during 2MT. 12MDP trials showed a significant decrease in accuracy over multiple phases, but accuracy could be enhanced significantly by resetting the reference point and/or compensating for initial Inertial frame estimation reference for each phase. INTERPRETATION: The variation in AHRS accuracy observed between the different systems and with time can be attributed in part to the dynamic estimation error, but also and foremost, to the ability of AHRS units to locate the same Inertial frame. CONCLUSIONS: Mean accuracies obtained under the Gimbal table sustained conditions of motion suggest that AHRS are promising tools for clinical mobility assessment under constrained conditions of use. However, improvement in magnetic compensation and alignment between AHRS modules are desirable in order for AHRS to reach their full potential in capturing clinical outcomes.
format Online
Article
Text
id pubmed-4374941
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-43749412015-04-04 Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time Lebel, Karina Boissy, Patrick Hamel, Mathieu Duval, Christian PLoS One Research Article BACKGROUND: Interest in 3D inertial motion tracking devices (AHRS) has been growing rapidly among the biomechanical community. Although the convenience of such tracking devices seems to open a whole new world of possibilities for evaluation in clinical biomechanics, its limitations haven’t been extensively documented. The objectives of this study are: 1) to assess the change in absolute and relative accuracy of multiple units of 3 commercially available AHRS over time; and 2) to identify different sources of errors affecting AHRS accuracy and to document how they may affect the measurements over time. METHODS: This study used an instrumented Gimbal table on which AHRS modules were carefully attached and put through a series of velocity-controlled sustained motions including 2 minutes motion trials (2MT) and 12 minutes multiple dynamic phases motion trials (12MDP). Absolute accuracy was assessed by comparison of the AHRS orientation measurements to those of an optical gold standard. Relative accuracy was evaluated using the variation in relative orientation between modules during the trials. FINDINGS: Both absolute and relative accuracy decreased over time during 2MT. 12MDP trials showed a significant decrease in accuracy over multiple phases, but accuracy could be enhanced significantly by resetting the reference point and/or compensating for initial Inertial frame estimation reference for each phase. INTERPRETATION: The variation in AHRS accuracy observed between the different systems and with time can be attributed in part to the dynamic estimation error, but also and foremost, to the ability of AHRS units to locate the same Inertial frame. CONCLUSIONS: Mean accuracies obtained under the Gimbal table sustained conditions of motion suggest that AHRS are promising tools for clinical mobility assessment under constrained conditions of use. However, improvement in magnetic compensation and alignment between AHRS modules are desirable in order for AHRS to reach their full potential in capturing clinical outcomes. Public Library of Science 2015-03-26 /pmc/articles/PMC4374941/ /pubmed/25811838 http://dx.doi.org/10.1371/journal.pone.0118361 Text en © 2015 Lebel et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Lebel, Karina
Boissy, Patrick
Hamel, Mathieu
Duval, Christian
Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time
title Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time
title_full Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time
title_fullStr Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time
title_full_unstemmed Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time
title_short Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions – Changes in Accuracy over Time
title_sort inertial measures of motion for clinical biomechanics: comparative assessment of accuracy under controlled conditions – changes in accuracy over time
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4374941/
https://www.ncbi.nlm.nih.gov/pubmed/25811838
http://dx.doi.org/10.1371/journal.pone.0118361
work_keys_str_mv AT lebelkarina inertialmeasuresofmotionforclinicalbiomechanicscomparativeassessmentofaccuracyundercontrolledconditionschangesinaccuracyovertime
AT boissypatrick inertialmeasuresofmotionforclinicalbiomechanicscomparativeassessmentofaccuracyundercontrolledconditionschangesinaccuracyovertime
AT hamelmathieu inertialmeasuresofmotionforclinicalbiomechanicscomparativeassessmentofaccuracyundercontrolledconditionschangesinaccuracyovertime
AT duvalchristian inertialmeasuresofmotionforclinicalbiomechanicscomparativeassessmentofaccuracyundercontrolledconditionschangesinaccuracyovertime