Cargando…

Single-Port Onlay Mesh Repair of Recurrent Inguinal Hernias after Failed Anterior and Laparoscopic Repairs

BACKGROUND AND OBJECTIVES: Despite the exponential increase in the use of laparoscopic inguinal herniorrhaphy, overall recurrence rates have remained unchanged. Therefore, a growing number of patients are presenting with recurrent hernias after conventional anterior and laparoscopic repairs have fai...

Descripción completa

Detalles Bibliográficos
Autores principales: Tran, Hanh, Tran, Kim, Zajkowska, Marta, Lam, Vincent, Hawthorne, Wayne J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Laparoendoscopic Surgeons 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4376219/
https://www.ncbi.nlm.nih.gov/pubmed/25848186
http://dx.doi.org/10.4293/JSLS.2014.00212
_version_ 1782363707147288576
author Tran, Hanh
Tran, Kim
Zajkowska, Marta
Lam, Vincent
Hawthorne, Wayne J.
author_facet Tran, Hanh
Tran, Kim
Zajkowska, Marta
Lam, Vincent
Hawthorne, Wayne J.
author_sort Tran, Hanh
collection PubMed
description BACKGROUND AND OBJECTIVES: Despite the exponential increase in the use of laparoscopic inguinal herniorrhaphy, overall recurrence rates have remained unchanged. Therefore, a growing number of patients are presenting with recurrent hernias after conventional anterior and laparoscopic repairs have failed. This study reports our experience with single-incision laparoscopic (SIL) intraperitoneal onlay mesh (IPOM) repair of these hernias. METHODS: Patients referred with two or more recurrences of inguinal hernia underwent SIL-IPOM from November 1, 2009, to June 24, 2014. A 2.5-cm infraumbilical incision was made, and an SIL port was placed intraperitoneally. Modified dissection techniques were used: chopstick and inline dissection, 5.5-mm/52-cm/30° angled laparoscope, and conventional straight dissecting instruments. The peritoneum was incised above the pubic symphysis, and dissection was continued laterally and proximally, raising the inferior flap below the previous extraperitoneal mesh while reducing any direct, indirect, femoral, or cord lipoma before placement of antiadhesive mesh, which was fixed to the pubic ramus, as well as superiorly, with nonabsorbable tacks before the inferior border was fixed with fibrin sealant. The inferior peritoneal flap was then tacked back onto the mesh. RESULTS: Nine male patients underwent SIL-IPOM. Their mean age was 53 years and mean body mass index was 26.8 kg/m(2). Mean mesh size was 275 cm(2). Mean operation time was 125 minutes, with a hospital stay of 1 day. The umbilical scar length was 23 mm at the 6-week follow-up. There were no intra-/postoperative complications, port-site hernias, chronic groin pain, or recurrence of the hernia during a mean follow-up of 24 months. CONCLUSION: Inguinal hernias recurring after two or more failed conventional anterior and laparoscopic repairs can be safely and efficiently treated with SIL-IPOM.
format Online
Article
Text
id pubmed-4376219
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Society of Laparoendoscopic Surgeons
record_format MEDLINE/PubMed
spelling pubmed-43762192015-04-06 Single-Port Onlay Mesh Repair of Recurrent Inguinal Hernias after Failed Anterior and Laparoscopic Repairs Tran, Hanh Tran, Kim Zajkowska, Marta Lam, Vincent Hawthorne, Wayne J. JSLS Scientific Papers BACKGROUND AND OBJECTIVES: Despite the exponential increase in the use of laparoscopic inguinal herniorrhaphy, overall recurrence rates have remained unchanged. Therefore, a growing number of patients are presenting with recurrent hernias after conventional anterior and laparoscopic repairs have failed. This study reports our experience with single-incision laparoscopic (SIL) intraperitoneal onlay mesh (IPOM) repair of these hernias. METHODS: Patients referred with two or more recurrences of inguinal hernia underwent SIL-IPOM from November 1, 2009, to June 24, 2014. A 2.5-cm infraumbilical incision was made, and an SIL port was placed intraperitoneally. Modified dissection techniques were used: chopstick and inline dissection, 5.5-mm/52-cm/30° angled laparoscope, and conventional straight dissecting instruments. The peritoneum was incised above the pubic symphysis, and dissection was continued laterally and proximally, raising the inferior flap below the previous extraperitoneal mesh while reducing any direct, indirect, femoral, or cord lipoma before placement of antiadhesive mesh, which was fixed to the pubic ramus, as well as superiorly, with nonabsorbable tacks before the inferior border was fixed with fibrin sealant. The inferior peritoneal flap was then tacked back onto the mesh. RESULTS: Nine male patients underwent SIL-IPOM. Their mean age was 53 years and mean body mass index was 26.8 kg/m(2). Mean mesh size was 275 cm(2). Mean operation time was 125 minutes, with a hospital stay of 1 day. The umbilical scar length was 23 mm at the 6-week follow-up. There were no intra-/postoperative complications, port-site hernias, chronic groin pain, or recurrence of the hernia during a mean follow-up of 24 months. CONCLUSION: Inguinal hernias recurring after two or more failed conventional anterior and laparoscopic repairs can be safely and efficiently treated with SIL-IPOM. Society of Laparoendoscopic Surgeons 2015 /pmc/articles/PMC4376219/ /pubmed/25848186 http://dx.doi.org/10.4293/JSLS.2014.00212 Text en © 2015 by JSLS, Journal of the Society of Laparoendoscopic Surgeons. This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives License (http://creativecommons.org/licenses/by-nc-nd/3.0/us/), which permits for noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited and is not altered in any way.
spellingShingle Scientific Papers
Tran, Hanh
Tran, Kim
Zajkowska, Marta
Lam, Vincent
Hawthorne, Wayne J.
Single-Port Onlay Mesh Repair of Recurrent Inguinal Hernias after Failed Anterior and Laparoscopic Repairs
title Single-Port Onlay Mesh Repair of Recurrent Inguinal Hernias after Failed Anterior and Laparoscopic Repairs
title_full Single-Port Onlay Mesh Repair of Recurrent Inguinal Hernias after Failed Anterior and Laparoscopic Repairs
title_fullStr Single-Port Onlay Mesh Repair of Recurrent Inguinal Hernias after Failed Anterior and Laparoscopic Repairs
title_full_unstemmed Single-Port Onlay Mesh Repair of Recurrent Inguinal Hernias after Failed Anterior and Laparoscopic Repairs
title_short Single-Port Onlay Mesh Repair of Recurrent Inguinal Hernias after Failed Anterior and Laparoscopic Repairs
title_sort single-port onlay mesh repair of recurrent inguinal hernias after failed anterior and laparoscopic repairs
topic Scientific Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4376219/
https://www.ncbi.nlm.nih.gov/pubmed/25848186
http://dx.doi.org/10.4293/JSLS.2014.00212
work_keys_str_mv AT tranhanh singleportonlaymeshrepairofrecurrentinguinalherniasafterfailedanteriorandlaparoscopicrepairs
AT trankim singleportonlaymeshrepairofrecurrentinguinalherniasafterfailedanteriorandlaparoscopicrepairs
AT zajkowskamarta singleportonlaymeshrepairofrecurrentinguinalherniasafterfailedanteriorandlaparoscopicrepairs
AT lamvincent singleportonlaymeshrepairofrecurrentinguinalherniasafterfailedanteriorandlaparoscopicrepairs
AT hawthornewaynej singleportonlaymeshrepairofrecurrentinguinalherniasafterfailedanteriorandlaparoscopicrepairs