Cargando…
The German version of the Individualized Care Scale – assessing validity and reliability
AIM: To assess validity and reliability of the German version of the Individualized Care Scale (ICS). BACKGROUND: Individualized nursing care plays a pivotal role in establishing patient-centered care. To assess individualized nursing care and to compare it in different settings and countries, valid...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4376256/ https://www.ncbi.nlm.nih.gov/pubmed/25848227 http://dx.doi.org/10.2147/PPA.S77486 |
_version_ | 1782363713222737920 |
---|---|
author | Köberich, Stefan Suhonen, Riitta Feuchtinger, Johanna Farin, Erik |
author_facet | Köberich, Stefan Suhonen, Riitta Feuchtinger, Johanna Farin, Erik |
author_sort | Köberich, Stefan |
collection | PubMed |
description | AIM: To assess validity and reliability of the German version of the Individualized Care Scale (ICS). BACKGROUND: Individualized nursing care plays a pivotal role in establishing patient-centered care. To assess individualized nursing care and to compare it in different settings and countries, valid and reliable instruments are needed. No psychometric-tested instrument for comparing individualized nursing care with other countries is available in Germany. DESIGN: Cross-sectional study. METHODS: Data were collected between September 2013 and June 2014 from 606 patients in 20 wards in five hospitals across Germany. Unidimensionality of the ICS scales ICSA (patients’ views on how individuality is supported through nursing interventions) and ICSB (patients’ perceptions of individualized nursing care) was analyzed by confirmatory factor analysis. Internal consistency was assessed by calculating Cronbach’s alpha. The Smoliner Scale (patients’ perceptions of the decision-making process in nursing care) and results from participating hospitals’ assessment of the nursing care delivery systems were used to assess known-groups validity and concurrent validity. RESULTS: Fit indices of confirmatory factor analysis indicate unidimensionality of the ICSA (Comparative Fit Index: 0.92; Tucker-Lewis Index: 0.902; root mean square error of approximation: 0.09; standardized root mean square residual: 0.05) and the ICSB (Comparative Fit Index: 0.91; Tucker-Lewis Index: 0.89; root mean square error of approximation: 0.09; standardized root mean square residual: 0.05). Internal consistency using Cronbach’s alpha was 0.95 (95% confidence interval: 0.94–0.95) for ICSA and 0.93 (95% confidence interval: 0.92–0.94) for the ICSB. Concurrent validity was established by a significant relationship between the Smoliner Scale and ICSA (r=0.66; P<0.01) and ICSB (r=0.72; P<0.01). Known-groups validity was approved by ICSA/ICSB score differences related to nursing care delivery systems and patients’ perceptions of decision-making style. CONCLUSION: The German version of the ICS is deemed a valid and reliable instrument for use in practice and research with hospitalized patients. |
format | Online Article Text |
id | pubmed-4376256 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-43762562015-04-06 The German version of the Individualized Care Scale – assessing validity and reliability Köberich, Stefan Suhonen, Riitta Feuchtinger, Johanna Farin, Erik Patient Prefer Adherence Original Research AIM: To assess validity and reliability of the German version of the Individualized Care Scale (ICS). BACKGROUND: Individualized nursing care plays a pivotal role in establishing patient-centered care. To assess individualized nursing care and to compare it in different settings and countries, valid and reliable instruments are needed. No psychometric-tested instrument for comparing individualized nursing care with other countries is available in Germany. DESIGN: Cross-sectional study. METHODS: Data were collected between September 2013 and June 2014 from 606 patients in 20 wards in five hospitals across Germany. Unidimensionality of the ICS scales ICSA (patients’ views on how individuality is supported through nursing interventions) and ICSB (patients’ perceptions of individualized nursing care) was analyzed by confirmatory factor analysis. Internal consistency was assessed by calculating Cronbach’s alpha. The Smoliner Scale (patients’ perceptions of the decision-making process in nursing care) and results from participating hospitals’ assessment of the nursing care delivery systems were used to assess known-groups validity and concurrent validity. RESULTS: Fit indices of confirmatory factor analysis indicate unidimensionality of the ICSA (Comparative Fit Index: 0.92; Tucker-Lewis Index: 0.902; root mean square error of approximation: 0.09; standardized root mean square residual: 0.05) and the ICSB (Comparative Fit Index: 0.91; Tucker-Lewis Index: 0.89; root mean square error of approximation: 0.09; standardized root mean square residual: 0.05). Internal consistency using Cronbach’s alpha was 0.95 (95% confidence interval: 0.94–0.95) for ICSA and 0.93 (95% confidence interval: 0.92–0.94) for the ICSB. Concurrent validity was established by a significant relationship between the Smoliner Scale and ICSA (r=0.66; P<0.01) and ICSB (r=0.72; P<0.01). Known-groups validity was approved by ICSA/ICSB score differences related to nursing care delivery systems and patients’ perceptions of decision-making style. CONCLUSION: The German version of the ICS is deemed a valid and reliable instrument for use in practice and research with hospitalized patients. Dove Medical Press 2015-03-23 /pmc/articles/PMC4376256/ /pubmed/25848227 http://dx.doi.org/10.2147/PPA.S77486 Text en © 2015 Köberich et al. This work is published by Dove Medical Press Limited, and licensed under Creative Commons Attribution – Non Commercial (unported, v3.0) License The full terms of the License are available at http://creativecommons.org/licenses/by-nc/3.0/. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Köberich, Stefan Suhonen, Riitta Feuchtinger, Johanna Farin, Erik The German version of the Individualized Care Scale – assessing validity and reliability |
title | The German version of the Individualized Care Scale – assessing validity and reliability |
title_full | The German version of the Individualized Care Scale – assessing validity and reliability |
title_fullStr | The German version of the Individualized Care Scale – assessing validity and reliability |
title_full_unstemmed | The German version of the Individualized Care Scale – assessing validity and reliability |
title_short | The German version of the Individualized Care Scale – assessing validity and reliability |
title_sort | german version of the individualized care scale – assessing validity and reliability |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4376256/ https://www.ncbi.nlm.nih.gov/pubmed/25848227 http://dx.doi.org/10.2147/PPA.S77486 |
work_keys_str_mv | AT koberichstefan thegermanversionoftheindividualizedcarescaleassessingvalidityandreliability AT suhonenriitta thegermanversionoftheindividualizedcarescaleassessingvalidityandreliability AT feuchtingerjohanna thegermanversionoftheindividualizedcarescaleassessingvalidityandreliability AT farinerik thegermanversionoftheindividualizedcarescaleassessingvalidityandreliability AT koberichstefan germanversionoftheindividualizedcarescaleassessingvalidityandreliability AT suhonenriitta germanversionoftheindividualizedcarescaleassessingvalidityandreliability AT feuchtingerjohanna germanversionoftheindividualizedcarescaleassessingvalidityandreliability AT farinerik germanversionoftheindividualizedcarescaleassessingvalidityandreliability |