Cargando…

The Validity and Reliability of an Arabic Version of the STOP-Bang Questionnaire for Identifying Obstructive Sleep Apnea

BACKGROUND: Obstructive sleep apnea (OSA) is a common, serious, under-recognized and under-diagnosed medical disorder. Polysomnography (PSG) is the gold standard diagnostic test for OSA; however, the cost of testing and the shortage of sleep disorders laboratories limit access to this tool. Therefor...

Descripción completa

Detalles Bibliográficos
Autores principales: BaHammam, Ahmed S., Al-Aqeel, Alaa M., Alhedyani, Alanoud A., Al-Obaid, Ghaida I., Al-Owais, Mashail M., Olaish, Awad H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4378065/
https://www.ncbi.nlm.nih.gov/pubmed/25834656
http://dx.doi.org/10.2174/1874306401509010022
_version_ 1782364013497155584
author BaHammam, Ahmed S.
Al-Aqeel, Alaa M.
Alhedyani, Alanoud A.
Al-Obaid, Ghaida I.
Al-Owais, Mashail M.
Olaish, Awad H.
author_facet BaHammam, Ahmed S.
Al-Aqeel, Alaa M.
Alhedyani, Alanoud A.
Al-Obaid, Ghaida I.
Al-Owais, Mashail M.
Olaish, Awad H.
author_sort BaHammam, Ahmed S.
collection PubMed
description BACKGROUND: Obstructive sleep apnea (OSA) is a common, serious, under-recognized and under-diagnosed medical disorder. Polysomnography (PSG) is the gold standard diagnostic test for OSA; however, the cost of testing and the shortage of sleep disorders laboratories limit access to this tool. Therefore, there is a need for a simple and reliable diagnostic tool to screen patients at risk of OSA. OBJECTIVE: This study was conducted to evaluate the validity and reliability of an Arabic version of the STOP-Bang questionnaire (SBQ) as a screening tool for OSA. METHODS: This study was conducted in three steps, as follows: Step 1: the SBQ was translated from English to Arabic (examining both forward and backward translations); Step 2: the test-retest reliability of the questionnaire was investigated; and Step 3: the questionnaire was validated against PSG data prospectively on 100 patients attending a sleep disorders clinic who were subjected to a full-night PSG study after completing the translated version of the SBQ. The validity of the test was tested against the apnea-hypopnea index (AHI). RESULTS: The study group had a mean age of 46.6 ± 14.0 years and a mean AHI of 50.0 ± 37.0/hour. The study demonstrated a high degree of internal consistency and stability over time for the translated SBQ. The Cronbach’s alpha coefficient for the 8-item tool was 0.7. Validation of the SBQ against the AHI at a cut-off of 5 revealed a sensitivity of 98% and positive and negative predictive values of 86% and 67%, respectively. CONCLUSION: The Arabic version of the SBQ is an easy-to-administer, simple, reliable and valid tool for the identification of OSA in the sleep disorders clinic setting.
format Online
Article
Text
id pubmed-4378065
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-43780652015-04-01 The Validity and Reliability of an Arabic Version of the STOP-Bang Questionnaire for Identifying Obstructive Sleep Apnea BaHammam, Ahmed S. Al-Aqeel, Alaa M. Alhedyani, Alanoud A. Al-Obaid, Ghaida I. Al-Owais, Mashail M. Olaish, Awad H. Open Respir Med J Article BACKGROUND: Obstructive sleep apnea (OSA) is a common, serious, under-recognized and under-diagnosed medical disorder. Polysomnography (PSG) is the gold standard diagnostic test for OSA; however, the cost of testing and the shortage of sleep disorders laboratories limit access to this tool. Therefore, there is a need for a simple and reliable diagnostic tool to screen patients at risk of OSA. OBJECTIVE: This study was conducted to evaluate the validity and reliability of an Arabic version of the STOP-Bang questionnaire (SBQ) as a screening tool for OSA. METHODS: This study was conducted in three steps, as follows: Step 1: the SBQ was translated from English to Arabic (examining both forward and backward translations); Step 2: the test-retest reliability of the questionnaire was investigated; and Step 3: the questionnaire was validated against PSG data prospectively on 100 patients attending a sleep disorders clinic who were subjected to a full-night PSG study after completing the translated version of the SBQ. The validity of the test was tested against the apnea-hypopnea index (AHI). RESULTS: The study group had a mean age of 46.6 ± 14.0 years and a mean AHI of 50.0 ± 37.0/hour. The study demonstrated a high degree of internal consistency and stability over time for the translated SBQ. The Cronbach’s alpha coefficient for the 8-item tool was 0.7. Validation of the SBQ against the AHI at a cut-off of 5 revealed a sensitivity of 98% and positive and negative predictive values of 86% and 67%, respectively. CONCLUSION: The Arabic version of the SBQ is an easy-to-administer, simple, reliable and valid tool for the identification of OSA in the sleep disorders clinic setting. Bentham Open 2015-02-27 /pmc/articles/PMC4378065/ /pubmed/25834656 http://dx.doi.org/10.2174/1874306401509010022 Text en © BaHammam et al.; Licensee Bentham Open. http://creativecommons.org/licenses/by-nc/3.0/ This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
BaHammam, Ahmed S.
Al-Aqeel, Alaa M.
Alhedyani, Alanoud A.
Al-Obaid, Ghaida I.
Al-Owais, Mashail M.
Olaish, Awad H.
The Validity and Reliability of an Arabic Version of the STOP-Bang Questionnaire for Identifying Obstructive Sleep Apnea
title The Validity and Reliability of an Arabic Version of the STOP-Bang Questionnaire for Identifying Obstructive Sleep Apnea
title_full The Validity and Reliability of an Arabic Version of the STOP-Bang Questionnaire for Identifying Obstructive Sleep Apnea
title_fullStr The Validity and Reliability of an Arabic Version of the STOP-Bang Questionnaire for Identifying Obstructive Sleep Apnea
title_full_unstemmed The Validity and Reliability of an Arabic Version of the STOP-Bang Questionnaire for Identifying Obstructive Sleep Apnea
title_short The Validity and Reliability of an Arabic Version of the STOP-Bang Questionnaire for Identifying Obstructive Sleep Apnea
title_sort validity and reliability of an arabic version of the stop-bang questionnaire for identifying obstructive sleep apnea
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4378065/
https://www.ncbi.nlm.nih.gov/pubmed/25834656
http://dx.doi.org/10.2174/1874306401509010022
work_keys_str_mv AT bahammamahmeds thevalidityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea
AT alaqeelalaam thevalidityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea
AT alhedyanialanouda thevalidityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea
AT alobaidghaidai thevalidityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea
AT alowaismashailm thevalidityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea
AT olaishawadh thevalidityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea
AT bahammamahmeds validityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea
AT alaqeelalaam validityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea
AT alhedyanialanouda validityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea
AT alobaidghaidai validityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea
AT alowaismashailm validityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea
AT olaishawadh validityandreliabilityofanarabicversionofthestopbangquestionnaireforidentifyingobstructivesleepapnea