Cargando…

Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector

BACKGROUND: Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. OBJECTIVE: An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liq...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jiwoo, Weon, Jin Bae, Yun, Bo-Ra, Eom, Min Rye, Ma, Choong Je
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4378127/
https://www.ncbi.nlm.nih.gov/pubmed/25829768
http://dx.doi.org/10.4103/0973-1296.153082
_version_ 1782364021799780352
author Lee, Jiwoo
Weon, Jin Bae
Yun, Bo-Ra
Eom, Min Rye
Ma, Choong Je
author_facet Lee, Jiwoo
Weon, Jin Bae
Yun, Bo-Ra
Eom, Min Rye
Ma, Choong Je
author_sort Lee, Jiwoo
collection PubMed
description BACKGROUND: Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. OBJECTIVE: An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liquid chromatography–mass spectrometry for the simultaneous determination of three phytosterol compounds, campesterol, stigmasterol and daucosterol in A. apiacea was established. MATERIALS AND METHODS: The analytes were separated on a Shiseido C(18) column (5 μm, 4.6 mm I.D. ×250 mm) with gradient elution of 0.1% trifluoroacetic acid and acetonitrile. The flow rate was 1 mL/min and detection wavelengths were set at 205 and 254 nm. RESULTS: Validation of the method was performed to demonstrate its linearity, precision and accuracy. The calibration curves showed good linearity (R(2) > 0.9994). The limits of detection and limits of quantification were within the ranges 0.55–7.07 μg/mL and 1.67–21.44 μg/mL, respectively. And, the relative standard deviations of intra- and inter-day precision were <2.93%. The recoveries were found to be in the range of 90.03–104.91%. CONCLUSION: The developed method has been successfully applied to the analysis for quality control of campesterol, stigmasterol and daucosterol in A. apiacea.
format Online
Article
Text
id pubmed-4378127
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-43781272015-04-01 Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector Lee, Jiwoo Weon, Jin Bae Yun, Bo-Ra Eom, Min Rye Ma, Choong Je Pharmacogn Mag Original Article BACKGROUND: Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. OBJECTIVE: An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liquid chromatography–mass spectrometry for the simultaneous determination of three phytosterol compounds, campesterol, stigmasterol and daucosterol in A. apiacea was established. MATERIALS AND METHODS: The analytes were separated on a Shiseido C(18) column (5 μm, 4.6 mm I.D. ×250 mm) with gradient elution of 0.1% trifluoroacetic acid and acetonitrile. The flow rate was 1 mL/min and detection wavelengths were set at 205 and 254 nm. RESULTS: Validation of the method was performed to demonstrate its linearity, precision and accuracy. The calibration curves showed good linearity (R(2) > 0.9994). The limits of detection and limits of quantification were within the ranges 0.55–7.07 μg/mL and 1.67–21.44 μg/mL, respectively. And, the relative standard deviations of intra- and inter-day precision were <2.93%. The recoveries were found to be in the range of 90.03–104.91%. CONCLUSION: The developed method has been successfully applied to the analysis for quality control of campesterol, stigmasterol and daucosterol in A. apiacea. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4378127/ /pubmed/25829768 http://dx.doi.org/10.4103/0973-1296.153082 Text en Copyright: © Pharmacognosy Magazine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Lee, Jiwoo
Weon, Jin Bae
Yun, Bo-Ra
Eom, Min Rye
Ma, Choong Je
Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector
title Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector
title_full Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector
title_fullStr Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector
title_full_unstemmed Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector
title_short Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector
title_sort simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4378127/
https://www.ncbi.nlm.nih.gov/pubmed/25829768
http://dx.doi.org/10.4103/0973-1296.153082
work_keys_str_mv AT leejiwoo simultaneousdeterminationthreephytosterolcompoundscampesterolstigmasterolanddaucosterolinartemisiaapiaceabyhighperformanceliquidchromatographydiodearrayultravioletvisibledetector
AT weonjinbae simultaneousdeterminationthreephytosterolcompoundscampesterolstigmasterolanddaucosterolinartemisiaapiaceabyhighperformanceliquidchromatographydiodearrayultravioletvisibledetector
AT yunbora simultaneousdeterminationthreephytosterolcompoundscampesterolstigmasterolanddaucosterolinartemisiaapiaceabyhighperformanceliquidchromatographydiodearrayultravioletvisibledetector
AT eomminrye simultaneousdeterminationthreephytosterolcompoundscampesterolstigmasterolanddaucosterolinartemisiaapiaceabyhighperformanceliquidchromatographydiodearrayultravioletvisibledetector
AT machoongje simultaneousdeterminationthreephytosterolcompoundscampesterolstigmasterolanddaucosterolinartemisiaapiaceabyhighperformanceliquidchromatographydiodearrayultravioletvisibledetector