Cargando…
Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector
BACKGROUND: Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. OBJECTIVE: An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liq...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4378127/ https://www.ncbi.nlm.nih.gov/pubmed/25829768 http://dx.doi.org/10.4103/0973-1296.153082 |
_version_ | 1782364021799780352 |
---|---|
author | Lee, Jiwoo Weon, Jin Bae Yun, Bo-Ra Eom, Min Rye Ma, Choong Je |
author_facet | Lee, Jiwoo Weon, Jin Bae Yun, Bo-Ra Eom, Min Rye Ma, Choong Je |
author_sort | Lee, Jiwoo |
collection | PubMed |
description | BACKGROUND: Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. OBJECTIVE: An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liquid chromatography–mass spectrometry for the simultaneous determination of three phytosterol compounds, campesterol, stigmasterol and daucosterol in A. apiacea was established. MATERIALS AND METHODS: The analytes were separated on a Shiseido C(18) column (5 μm, 4.6 mm I.D. ×250 mm) with gradient elution of 0.1% trifluoroacetic acid and acetonitrile. The flow rate was 1 mL/min and detection wavelengths were set at 205 and 254 nm. RESULTS: Validation of the method was performed to demonstrate its linearity, precision and accuracy. The calibration curves showed good linearity (R(2) > 0.9994). The limits of detection and limits of quantification were within the ranges 0.55–7.07 μg/mL and 1.67–21.44 μg/mL, respectively. And, the relative standard deviations of intra- and inter-day precision were <2.93%. The recoveries were found to be in the range of 90.03–104.91%. CONCLUSION: The developed method has been successfully applied to the analysis for quality control of campesterol, stigmasterol and daucosterol in A. apiacea. |
format | Online Article Text |
id | pubmed-4378127 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-43781272015-04-01 Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector Lee, Jiwoo Weon, Jin Bae Yun, Bo-Ra Eom, Min Rye Ma, Choong Je Pharmacogn Mag Original Article BACKGROUND: Artemisia apiacea is a traditional herbal medicine using treatment of eczema and jaundice in Eastern Asia, including China, Korea, and Japan. OBJECTIVE: An accurate and sensitive analysis method using high performance liquid chromatography-diode array ultraviolet/visible detector and liquid chromatography–mass spectrometry for the simultaneous determination of three phytosterol compounds, campesterol, stigmasterol and daucosterol in A. apiacea was established. MATERIALS AND METHODS: The analytes were separated on a Shiseido C(18) column (5 μm, 4.6 mm I.D. ×250 mm) with gradient elution of 0.1% trifluoroacetic acid and acetonitrile. The flow rate was 1 mL/min and detection wavelengths were set at 205 and 254 nm. RESULTS: Validation of the method was performed to demonstrate its linearity, precision and accuracy. The calibration curves showed good linearity (R(2) > 0.9994). The limits of detection and limits of quantification were within the ranges 0.55–7.07 μg/mL and 1.67–21.44 μg/mL, respectively. And, the relative standard deviations of intra- and inter-day precision were <2.93%. The recoveries were found to be in the range of 90.03–104.91%. CONCLUSION: The developed method has been successfully applied to the analysis for quality control of campesterol, stigmasterol and daucosterol in A. apiacea. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4378127/ /pubmed/25829768 http://dx.doi.org/10.4103/0973-1296.153082 Text en Copyright: © Pharmacognosy Magazine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Lee, Jiwoo Weon, Jin Bae Yun, Bo-Ra Eom, Min Rye Ma, Choong Je Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector |
title | Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector |
title_full | Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector |
title_fullStr | Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector |
title_full_unstemmed | Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector |
title_short | Simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in Artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector |
title_sort | simultaneous determination three phytosterol compounds, campesterol, stigmasterol and daucosterol in artemisia apiacea by high performance liquid chromatography-diode array ultraviolet/visible detector |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4378127/ https://www.ncbi.nlm.nih.gov/pubmed/25829768 http://dx.doi.org/10.4103/0973-1296.153082 |
work_keys_str_mv | AT leejiwoo simultaneousdeterminationthreephytosterolcompoundscampesterolstigmasterolanddaucosterolinartemisiaapiaceabyhighperformanceliquidchromatographydiodearrayultravioletvisibledetector AT weonjinbae simultaneousdeterminationthreephytosterolcompoundscampesterolstigmasterolanddaucosterolinartemisiaapiaceabyhighperformanceliquidchromatographydiodearrayultravioletvisibledetector AT yunbora simultaneousdeterminationthreephytosterolcompoundscampesterolstigmasterolanddaucosterolinartemisiaapiaceabyhighperformanceliquidchromatographydiodearrayultravioletvisibledetector AT eomminrye simultaneousdeterminationthreephytosterolcompoundscampesterolstigmasterolanddaucosterolinartemisiaapiaceabyhighperformanceliquidchromatographydiodearrayultravioletvisibledetector AT machoongje simultaneousdeterminationthreephytosterolcompoundscampesterolstigmasterolanddaucosterolinartemisiaapiaceabyhighperformanceliquidchromatographydiodearrayultravioletvisibledetector |