Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples
Advances in the “omics” field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4379062/ https://www.ncbi.nlm.nih.gov/pubmed/25823017 http://dx.doi.org/10.1371/journal.pone.0121495 |
_version_ | 1782364137730342912 |
---|---|
author | Anton, Gabriele Wilson, Rory Yu, Zhong-hao Prehn, Cornelia Zukunft, Sven Adamski, Jerzy Heier, Margit Meisinger, Christa Römisch-Margl, Werner Wang-Sattler, Rui Hveem, Kristian Wolfenbuttel, Bruce Peters, Annette Kastenmüller, Gabi Waldenberger, Melanie |
author_facet | Anton, Gabriele Wilson, Rory Yu, Zhong-hao Prehn, Cornelia Zukunft, Sven Adamski, Jerzy Heier, Margit Meisinger, Christa Römisch-Margl, Werner Wang-Sattler, Rui Hveem, Kristian Wolfenbuttel, Bruce Peters, Annette Kastenmüller, Gabi Waldenberger, Melanie |
author_sort | Anton, Gabriele |
collection | PubMed |
description | Advances in the “omics” field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-analytical phase as well as markers to distinguish between ‘good’ and ‘bad’ quality samples taking into account the desired downstream analysis are urgently needed. We studied concentration changes of metabolites in serum samples due to pre-storage handling conditions as well as due to repeated freeze-thaw cycles. We collected fasting serum samples and subjected aliquots to up to four freeze-thaw cycles and to pre-storage handling delays of 12, 24 and 36 hours at room temperature (RT) and on wet and dry ice. For each treated aliquot, we quantified 127 metabolites through a targeted metabolomics approach. We found a clear signature of degradation in samples kept at RT. Storage on wet ice led to less pronounced concentration changes. 24 metabolites showed significant concentration changes at RT. In 22 of these, changes were already visible after only 12 hours of storage delay. Especially pronounced were increases in lysophosphatidylcholines and decreases in phosphatidylcholines. We showed that the ratio between the concentrations of these molecule classes could serve as a measure to distinguish between ‘good’ and ‘bad’ quality samples in our study. In contrast, we found quite stable metabolite concentrations during up to four freeze-thaw cycles. We concluded that pre-analytical RT handling of serum samples should be strictly avoided and serum samples should always be handled on wet ice or in cooling devices after centrifugation. Moreover, serum samples should be frozen at or below -80°C as soon as possible after centrifugation. |
format | Online Article Text |
id | pubmed-4379062 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-43790622015-04-09 Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples Anton, Gabriele Wilson, Rory Yu, Zhong-hao Prehn, Cornelia Zukunft, Sven Adamski, Jerzy Heier, Margit Meisinger, Christa Römisch-Margl, Werner Wang-Sattler, Rui Hveem, Kristian Wolfenbuttel, Bruce Peters, Annette Kastenmüller, Gabi Waldenberger, Melanie PLoS One Research Article Advances in the “omics” field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-analytical phase as well as markers to distinguish between ‘good’ and ‘bad’ quality samples taking into account the desired downstream analysis are urgently needed. We studied concentration changes of metabolites in serum samples due to pre-storage handling conditions as well as due to repeated freeze-thaw cycles. We collected fasting serum samples and subjected aliquots to up to four freeze-thaw cycles and to pre-storage handling delays of 12, 24 and 36 hours at room temperature (RT) and on wet and dry ice. For each treated aliquot, we quantified 127 metabolites through a targeted metabolomics approach. We found a clear signature of degradation in samples kept at RT. Storage on wet ice led to less pronounced concentration changes. 24 metabolites showed significant concentration changes at RT. In 22 of these, changes were already visible after only 12 hours of storage delay. Especially pronounced were increases in lysophosphatidylcholines and decreases in phosphatidylcholines. We showed that the ratio between the concentrations of these molecule classes could serve as a measure to distinguish between ‘good’ and ‘bad’ quality samples in our study. In contrast, we found quite stable metabolite concentrations during up to four freeze-thaw cycles. We concluded that pre-analytical RT handling of serum samples should be strictly avoided and serum samples should always be handled on wet ice or in cooling devices after centrifugation. Moreover, serum samples should be frozen at or below -80°C as soon as possible after centrifugation. Public Library of Science 2015-03-30 /pmc/articles/PMC4379062/ /pubmed/25823017 http://dx.doi.org/10.1371/journal.pone.0121495 Text en © 2015 Anton et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited. |
spellingShingle | Research Article Anton, Gabriele Wilson, Rory Yu, Zhong-hao Prehn, Cornelia Zukunft, Sven Adamski, Jerzy Heier, Margit Meisinger, Christa Römisch-Margl, Werner Wang-Sattler, Rui Hveem, Kristian Wolfenbuttel, Bruce Peters, Annette Kastenmüller, Gabi Waldenberger, Melanie Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples |
title | Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples |
title_full | Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples |
title_fullStr | Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples |
title_full_unstemmed | Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples |
title_short | Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples |
title_sort | pre-analytical sample quality: metabolite ratios as an intrinsic marker for prolonged room temperature exposure of serum samples |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4379062/ https://www.ncbi.nlm.nih.gov/pubmed/25823017 http://dx.doi.org/10.1371/journal.pone.0121495 |
work_keys_str_mv | AT antongabriele preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT wilsonrory preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT yuzhonghao preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT prehncornelia preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT zukunftsven preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT adamskijerzy preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT heiermargit preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT meisingerchrista preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT romischmarglwerner preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT wangsattlerrui preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT hveemkristian preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT wolfenbuttelbruce preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT petersannette preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT kastenmullergabi preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples AT waldenbergermelanie preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples |