Cargando…

Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples

Advances in the “omics” field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-...

Descripción completa

Detalles Bibliográficos
Autores principales: Anton, Gabriele, Wilson, Rory, Yu, Zhong-hao, Prehn, Cornelia, Zukunft, Sven, Adamski, Jerzy, Heier, Margit, Meisinger, Christa, Römisch-Margl, Werner, Wang-Sattler, Rui, Hveem, Kristian, Wolfenbuttel, Bruce, Peters, Annette, Kastenmüller, Gabi, Waldenberger, Melanie
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4379062/
https://www.ncbi.nlm.nih.gov/pubmed/25823017
http://dx.doi.org/10.1371/journal.pone.0121495
_version_ 1782364137730342912
author Anton, Gabriele
Wilson, Rory
Yu, Zhong-hao
Prehn, Cornelia
Zukunft, Sven
Adamski, Jerzy
Heier, Margit
Meisinger, Christa
Römisch-Margl, Werner
Wang-Sattler, Rui
Hveem, Kristian
Wolfenbuttel, Bruce
Peters, Annette
Kastenmüller, Gabi
Waldenberger, Melanie
author_facet Anton, Gabriele
Wilson, Rory
Yu, Zhong-hao
Prehn, Cornelia
Zukunft, Sven
Adamski, Jerzy
Heier, Margit
Meisinger, Christa
Römisch-Margl, Werner
Wang-Sattler, Rui
Hveem, Kristian
Wolfenbuttel, Bruce
Peters, Annette
Kastenmüller, Gabi
Waldenberger, Melanie
author_sort Anton, Gabriele
collection PubMed
description Advances in the “omics” field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-analytical phase as well as markers to distinguish between ‘good’ and ‘bad’ quality samples taking into account the desired downstream analysis are urgently needed. We studied concentration changes of metabolites in serum samples due to pre-storage handling conditions as well as due to repeated freeze-thaw cycles. We collected fasting serum samples and subjected aliquots to up to four freeze-thaw cycles and to pre-storage handling delays of 12, 24 and 36 hours at room temperature (RT) and on wet and dry ice. For each treated aliquot, we quantified 127 metabolites through a targeted metabolomics approach. We found a clear signature of degradation in samples kept at RT. Storage on wet ice led to less pronounced concentration changes. 24 metabolites showed significant concentration changes at RT. In 22 of these, changes were already visible after only 12 hours of storage delay. Especially pronounced were increases in lysophosphatidylcholines and decreases in phosphatidylcholines. We showed that the ratio between the concentrations of these molecule classes could serve as a measure to distinguish between ‘good’ and ‘bad’ quality samples in our study. In contrast, we found quite stable metabolite concentrations during up to four freeze-thaw cycles. We concluded that pre-analytical RT handling of serum samples should be strictly avoided and serum samples should always be handled on wet ice or in cooling devices after centrifugation. Moreover, serum samples should be frozen at or below -80°C as soon as possible after centrifugation.
format Online
Article
Text
id pubmed-4379062
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-43790622015-04-09 Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples Anton, Gabriele Wilson, Rory Yu, Zhong-hao Prehn, Cornelia Zukunft, Sven Adamski, Jerzy Heier, Margit Meisinger, Christa Römisch-Margl, Werner Wang-Sattler, Rui Hveem, Kristian Wolfenbuttel, Bruce Peters, Annette Kastenmüller, Gabi Waldenberger, Melanie PLoS One Research Article Advances in the “omics” field bring about the need for a high number of good quality samples. Many omics studies take advantage of biobanked samples to meet this need. Most of the laboratory errors occur in the pre-analytical phase. Therefore evidence-based standard operating procedures for the pre-analytical phase as well as markers to distinguish between ‘good’ and ‘bad’ quality samples taking into account the desired downstream analysis are urgently needed. We studied concentration changes of metabolites in serum samples due to pre-storage handling conditions as well as due to repeated freeze-thaw cycles. We collected fasting serum samples and subjected aliquots to up to four freeze-thaw cycles and to pre-storage handling delays of 12, 24 and 36 hours at room temperature (RT) and on wet and dry ice. For each treated aliquot, we quantified 127 metabolites through a targeted metabolomics approach. We found a clear signature of degradation in samples kept at RT. Storage on wet ice led to less pronounced concentration changes. 24 metabolites showed significant concentration changes at RT. In 22 of these, changes were already visible after only 12 hours of storage delay. Especially pronounced were increases in lysophosphatidylcholines and decreases in phosphatidylcholines. We showed that the ratio between the concentrations of these molecule classes could serve as a measure to distinguish between ‘good’ and ‘bad’ quality samples in our study. In contrast, we found quite stable metabolite concentrations during up to four freeze-thaw cycles. We concluded that pre-analytical RT handling of serum samples should be strictly avoided and serum samples should always be handled on wet ice or in cooling devices after centrifugation. Moreover, serum samples should be frozen at or below -80°C as soon as possible after centrifugation. Public Library of Science 2015-03-30 /pmc/articles/PMC4379062/ /pubmed/25823017 http://dx.doi.org/10.1371/journal.pone.0121495 Text en © 2015 Anton et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Anton, Gabriele
Wilson, Rory
Yu, Zhong-hao
Prehn, Cornelia
Zukunft, Sven
Adamski, Jerzy
Heier, Margit
Meisinger, Christa
Römisch-Margl, Werner
Wang-Sattler, Rui
Hveem, Kristian
Wolfenbuttel, Bruce
Peters, Annette
Kastenmüller, Gabi
Waldenberger, Melanie
Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples
title Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples
title_full Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples
title_fullStr Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples
title_full_unstemmed Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples
title_short Pre-Analytical Sample Quality: Metabolite Ratios as an Intrinsic Marker for Prolonged Room Temperature Exposure of Serum Samples
title_sort pre-analytical sample quality: metabolite ratios as an intrinsic marker for prolonged room temperature exposure of serum samples
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4379062/
https://www.ncbi.nlm.nih.gov/pubmed/25823017
http://dx.doi.org/10.1371/journal.pone.0121495
work_keys_str_mv AT antongabriele preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT wilsonrory preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT yuzhonghao preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT prehncornelia preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT zukunftsven preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT adamskijerzy preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT heiermargit preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT meisingerchrista preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT romischmarglwerner preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT wangsattlerrui preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT hveemkristian preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT wolfenbuttelbruce preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT petersannette preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT kastenmullergabi preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples
AT waldenbergermelanie preanalyticalsamplequalitymetaboliteratiosasanintrinsicmarkerforprolongedroomtemperatureexposureofserumsamples