Cargando…

American Society of Biomechanics Journal of Biomechanics Award 2013: Cortical bone tissue mechanical quality and biological mechanisms possibly underlying atypical fractures

The biomechanics literature contains many well-understood mechanisms behind typical fracture types that have important roles in treatment planning. The recent association of “atypical” fractures with long-term use of drugs designed to prevent osteoporosis has renewed interest in the effects of agent...

Descripción completa

Detalles Bibliográficos
Autores principales: Geissler, Joseph R., Bajaj, Devendra, Fritton, J. Christopher
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4380555/
https://www.ncbi.nlm.nih.gov/pubmed/25683519
http://dx.doi.org/10.1016/j.jbiomech.2015.01.032
_version_ 1782364350049157120
author Geissler, Joseph R.
Bajaj, Devendra
Fritton, J. Christopher
author_facet Geissler, Joseph R.
Bajaj, Devendra
Fritton, J. Christopher
author_sort Geissler, Joseph R.
collection PubMed
description The biomechanics literature contains many well-understood mechanisms behind typical fracture types that have important roles in treatment planning. The recent association of “atypical” fractures with long-term use of drugs designed to prevent osteoporosis has renewed interest in the effects of agents on bone tissue-level quality. While this class of fracture was recognized prior to the introduction of the anti-resorptive bisphosphonate drugs and recently likened to stress fractures, the mechanism(s) that lead to atypical fractures have not been definitively identified. Thus, a causal relationship between these drugs and atypical fracture has not been established. Physicians, bioengineers and others interested in the biomechanics of bone are working to improve fracture-prevention diagnostics, and the design of treatments to avoid this serious side-effect in the future. This review examines the mechanisms behind the bone tissue damage that may produce the atypical fracture pattern observed increasingly with long-term bisphosphonate use. Our recent findings and those of others reviewed support that the mechanisms behind normal, healthy excavation and tunnel filling by bone remodeling units within cortical tissue strengthen mechanical integrity. The ability of cortical bone to resist the damage induced during cyclic loading may be altered by the reduced remodeling and increased tissue age resulting from long-term bisphosphonate treatment. Development of assessments for such potential fractures would restore confidence in pharmaceutical treatments that have the potential to spare millions in our aging population from the morbidity and death that often follow bone fracture.
format Online
Article
Text
id pubmed-4380555
institution National Center for Biotechnology Information
language English
publishDate 2015
record_format MEDLINE/PubMed
spelling pubmed-43805552016-04-13 American Society of Biomechanics Journal of Biomechanics Award 2013: Cortical bone tissue mechanical quality and biological mechanisms possibly underlying atypical fractures Geissler, Joseph R. Bajaj, Devendra Fritton, J. Christopher J Biomech Article The biomechanics literature contains many well-understood mechanisms behind typical fracture types that have important roles in treatment planning. The recent association of “atypical” fractures with long-term use of drugs designed to prevent osteoporosis has renewed interest in the effects of agents on bone tissue-level quality. While this class of fracture was recognized prior to the introduction of the anti-resorptive bisphosphonate drugs and recently likened to stress fractures, the mechanism(s) that lead to atypical fractures have not been definitively identified. Thus, a causal relationship between these drugs and atypical fracture has not been established. Physicians, bioengineers and others interested in the biomechanics of bone are working to improve fracture-prevention diagnostics, and the design of treatments to avoid this serious side-effect in the future. This review examines the mechanisms behind the bone tissue damage that may produce the atypical fracture pattern observed increasingly with long-term bisphosphonate use. Our recent findings and those of others reviewed support that the mechanisms behind normal, healthy excavation and tunnel filling by bone remodeling units within cortical tissue strengthen mechanical integrity. The ability of cortical bone to resist the damage induced during cyclic loading may be altered by the reduced remodeling and increased tissue age resulting from long-term bisphosphonate treatment. Development of assessments for such potential fractures would restore confidence in pharmaceutical treatments that have the potential to spare millions in our aging population from the morbidity and death that often follow bone fracture. 2015-02-02 2015-04-13 /pmc/articles/PMC4380555/ /pubmed/25683519 http://dx.doi.org/10.1016/j.jbiomech.2015.01.032 Text en © 2015 Published by Elsevier Ltd. http://creativecommons.org/licenses/by-nc/3.0/ This manuscript version is made available under the CC BY-NC-ND 4.0 license.
spellingShingle Article
Geissler, Joseph R.
Bajaj, Devendra
Fritton, J. Christopher
American Society of Biomechanics Journal of Biomechanics Award 2013: Cortical bone tissue mechanical quality and biological mechanisms possibly underlying atypical fractures
title American Society of Biomechanics Journal of Biomechanics Award 2013: Cortical bone tissue mechanical quality and biological mechanisms possibly underlying atypical fractures
title_full American Society of Biomechanics Journal of Biomechanics Award 2013: Cortical bone tissue mechanical quality and biological mechanisms possibly underlying atypical fractures
title_fullStr American Society of Biomechanics Journal of Biomechanics Award 2013: Cortical bone tissue mechanical quality and biological mechanisms possibly underlying atypical fractures
title_full_unstemmed American Society of Biomechanics Journal of Biomechanics Award 2013: Cortical bone tissue mechanical quality and biological mechanisms possibly underlying atypical fractures
title_short American Society of Biomechanics Journal of Biomechanics Award 2013: Cortical bone tissue mechanical quality and biological mechanisms possibly underlying atypical fractures
title_sort american society of biomechanics journal of biomechanics award 2013: cortical bone tissue mechanical quality and biological mechanisms possibly underlying atypical fractures
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4380555/
https://www.ncbi.nlm.nih.gov/pubmed/25683519
http://dx.doi.org/10.1016/j.jbiomech.2015.01.032
work_keys_str_mv AT geisslerjosephr americansocietyofbiomechanicsjournalofbiomechanicsaward2013corticalbonetissuemechanicalqualityandbiologicalmechanismspossiblyunderlyingatypicalfractures
AT bajajdevendra americansocietyofbiomechanicsjournalofbiomechanicsaward2013corticalbonetissuemechanicalqualityandbiologicalmechanismspossiblyunderlyingatypicalfractures
AT frittonjchristopher americansocietyofbiomechanicsjournalofbiomechanicsaward2013corticalbonetissuemechanicalqualityandbiologicalmechanismspossiblyunderlyingatypicalfractures