Evaluation of shear bond strength of orthodontic brackets using trans-illumination technique with different curing profiles of LED light-curing unit in posterior teeth
BACKGROUND: Although using light-cured composites for bonding orthodontic brackets has become increasingly popular, curing light cannot penetrate the metallic bulk of brackets and polymerization of composites is limited to the edges. Limited access and poor direct sight may be a problem in the poste...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2013
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4384940/ https://www.ncbi.nlm.nih.gov/pubmed/24325795 http://dx.doi.org/10.1186/2196-1042-14-49 |
_version_ | 1782364982438002688 |
---|---|
author | Heravi, Farzin Moazzami, Saied Mostafa Ghaffari, Negin Jalayer, Javad Bozorgnia, Yasaman |
author_facet | Heravi, Farzin Moazzami, Saied Mostafa Ghaffari, Negin Jalayer, Javad Bozorgnia, Yasaman |
author_sort | Heravi, Farzin |
collection | PubMed |
description | BACKGROUND: Although using light-cured composites for bonding orthodontic brackets has become increasingly popular, curing light cannot penetrate the metallic bulk of brackets and polymerization of composites is limited to the edges. Limited access and poor direct sight may be a problem in the posterior teeth. Meanwhile, effectiveness of the trans-illumination technique is questionable due to increased bucco-lingual thickness of the posterior teeth. Light-emitting diode (LED) light-curing units cause less temperature rise and lower risk to the pulpal tissue. The purpose of this study was to evaluate the clinical effectiveness of trans-illumination technique in bonding metallic brackets to premolars, using different light intensities and curing times of an LED light-curing unit. METHODS: Sixty premolars were randomly divided into six groups. Bonding of brackets was done with 40- and 80-s light curing from the buccal or lingual aspect with different intensities. Shear bond strengths of brackets were measured using a universal testing machine. Data were analyzed by one-way analysis of variance test and Duncan's post hoc test. RESULTS: The highest shear bond belonged to group 2 (high intensity, 40 s, buccal) and the lowest belonged to group 3 (low intensity, 40 s, lingual). Bond strength means in control groups were significantly higher than those in experimental groups. CONCLUSIONS: In all experimental groups except group 6 (80 s, high intensity, lingual), shear bond strength was below the clinically accepted values. In clinical limitations where light curing from the same side of the bracket is not possible, doubling the curing time and increasing the light intensity during trans-illumination are recommended for achieving acceptable bond strengths. |
format | Online Article Text |
id | pubmed-4384940 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2013 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-43849402015-04-04 Evaluation of shear bond strength of orthodontic brackets using trans-illumination technique with different curing profiles of LED light-curing unit in posterior teeth Heravi, Farzin Moazzami, Saied Mostafa Ghaffari, Negin Jalayer, Javad Bozorgnia, Yasaman Prog Orthod Research BACKGROUND: Although using light-cured composites for bonding orthodontic brackets has become increasingly popular, curing light cannot penetrate the metallic bulk of brackets and polymerization of composites is limited to the edges. Limited access and poor direct sight may be a problem in the posterior teeth. Meanwhile, effectiveness of the trans-illumination technique is questionable due to increased bucco-lingual thickness of the posterior teeth. Light-emitting diode (LED) light-curing units cause less temperature rise and lower risk to the pulpal tissue. The purpose of this study was to evaluate the clinical effectiveness of trans-illumination technique in bonding metallic brackets to premolars, using different light intensities and curing times of an LED light-curing unit. METHODS: Sixty premolars were randomly divided into six groups. Bonding of brackets was done with 40- and 80-s light curing from the buccal or lingual aspect with different intensities. Shear bond strengths of brackets were measured using a universal testing machine. Data were analyzed by one-way analysis of variance test and Duncan's post hoc test. RESULTS: The highest shear bond belonged to group 2 (high intensity, 40 s, buccal) and the lowest belonged to group 3 (low intensity, 40 s, lingual). Bond strength means in control groups were significantly higher than those in experimental groups. CONCLUSIONS: In all experimental groups except group 6 (80 s, high intensity, lingual), shear bond strength was below the clinically accepted values. In clinical limitations where light curing from the same side of the bracket is not possible, doubling the curing time and increasing the light intensity during trans-illumination are recommended for achieving acceptable bond strengths. Springer Berlin Heidelberg 2013-11-21 /pmc/articles/PMC4384940/ /pubmed/24325795 http://dx.doi.org/10.1186/2196-1042-14-49 Text en © Heravi et al.; licensee Springer. 2013 This article is published under license to BioMed Central Ltd. This is an open access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Heravi, Farzin Moazzami, Saied Mostafa Ghaffari, Negin Jalayer, Javad Bozorgnia, Yasaman Evaluation of shear bond strength of orthodontic brackets using trans-illumination technique with different curing profiles of LED light-curing unit in posterior teeth |
title | Evaluation of shear bond strength of orthodontic brackets using trans-illumination technique with different curing profiles of LED light-curing unit in posterior teeth |
title_full | Evaluation of shear bond strength of orthodontic brackets using trans-illumination technique with different curing profiles of LED light-curing unit in posterior teeth |
title_fullStr | Evaluation of shear bond strength of orthodontic brackets using trans-illumination technique with different curing profiles of LED light-curing unit in posterior teeth |
title_full_unstemmed | Evaluation of shear bond strength of orthodontic brackets using trans-illumination technique with different curing profiles of LED light-curing unit in posterior teeth |
title_short | Evaluation of shear bond strength of orthodontic brackets using trans-illumination technique with different curing profiles of LED light-curing unit in posterior teeth |
title_sort | evaluation of shear bond strength of orthodontic brackets using trans-illumination technique with different curing profiles of led light-curing unit in posterior teeth |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4384940/ https://www.ncbi.nlm.nih.gov/pubmed/24325795 http://dx.doi.org/10.1186/2196-1042-14-49 |
work_keys_str_mv | AT heravifarzin evaluationofshearbondstrengthoforthodonticbracketsusingtransilluminationtechniquewithdifferentcuringprofilesofledlightcuringunitinposteriorteeth AT moazzamisaiedmostafa evaluationofshearbondstrengthoforthodonticbracketsusingtransilluminationtechniquewithdifferentcuringprofilesofledlightcuringunitinposteriorteeth AT ghaffarinegin evaluationofshearbondstrengthoforthodonticbracketsusingtransilluminationtechniquewithdifferentcuringprofilesofledlightcuringunitinposteriorteeth AT jalayerjavad evaluationofshearbondstrengthoforthodonticbracketsusingtransilluminationtechniquewithdifferentcuringprofilesofledlightcuringunitinposteriorteeth AT bozorgniayasaman evaluationofshearbondstrengthoforthodonticbracketsusingtransilluminationtechniquewithdifferentcuringprofilesofledlightcuringunitinposteriorteeth |