Cargando…

Kinetics of pulpal temperature rise during light curing of 6 bonding agents from different generations, using light emitting diode and quartz-tungsten-halogen units: An in-vitro simulation

BACKGROUND: Application of bonding agents (BA) into deep cavities and light curing them might increase pulpal temperature and threaten its health. The purpose of this study was to evaluate temperature rise of pulp by light curing six BA using two different light curing units (LCU), through a dent in...

Descripción completa

Detalles Bibliográficos
Autores principales: Khaksaran, Najmeh Khatoon, Kashi, Tahereh Jafarzadeh, Rakhshan, Vahid, Zeynolabedin, Zahra Sadat, Bagheri, Hossein
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4387631/
https://www.ncbi.nlm.nih.gov/pubmed/25878684
_version_ 1782365296488611840
author Khaksaran, Najmeh Khatoon
Kashi, Tahereh Jafarzadeh
Rakhshan, Vahid
Zeynolabedin, Zahra Sadat
Bagheri, Hossein
author_facet Khaksaran, Najmeh Khatoon
Kashi, Tahereh Jafarzadeh
Rakhshan, Vahid
Zeynolabedin, Zahra Sadat
Bagheri, Hossein
author_sort Khaksaran, Najmeh Khatoon
collection PubMed
description BACKGROUND: Application of bonding agents (BA) into deep cavities and light curing them might increase pulpal temperature and threaten its health. The purpose of this study was to evaluate temperature rise of pulp by light curing six BA using two different light curing units (LCU), through a dent in wall of 0.5 mm. MATERIALS AND METHODS: This in vitro experiment was carried out on 96 slices of the same number of human third molars (6 BAs × 2 LCUs × 8 specimens in each group). There were 6 groups of BAs: N Bond, G-Bond, OptiBond XTR, Clearfil SE, Adper Single Bond 2 and V Bond. Each group of BA (n = 16) had two subgroups of light emitting diode (LED) and quartz-tungsten-halogen light cure units (n = 8). Each of these 16 specimens were subjected to light emitting for 20 s, once without any BAs (control) and later when a BA was applied to surface of disk. Temperature rises in 140 s were evaluated. Their mean temperature change in first 20 s were calculated and analyzed using two-way repeated-measures and one-way analysis of variance (ANOVA) and Tukey (α = 0.05). Furthermore rate of temperature increase was calculated for each material and LCU. RESULTS: Minimum and maximum temperature rises in all subgroups were 1.7 and 2.8°C, respectively. Repeated measures ANOVA showed that both of adhesive and LCU types had significant effect on temperature rise after application of adhesives. Tukey post-hoc analysis showed Clearfil SE showed significantly higher temperature rise in comparison with Adper Single bond 2 (P = 0.047) and N Bond (P = 0.038). Temperature rose in a linear fashion during first 30-40 s and after that it was non-linear. CONCLUSION: 20 s of light curing seems safe for pulpal health (with critical threshold of 5.5°C). However, in longer durations and especially when using LED units, the process should be broken to two sessions.
format Online
Article
Text
id pubmed-4387631
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-43876312015-04-15 Kinetics of pulpal temperature rise during light curing of 6 bonding agents from different generations, using light emitting diode and quartz-tungsten-halogen units: An in-vitro simulation Khaksaran, Najmeh Khatoon Kashi, Tahereh Jafarzadeh Rakhshan, Vahid Zeynolabedin, Zahra Sadat Bagheri, Hossein Dent Res J (Isfahan) Original Article BACKGROUND: Application of bonding agents (BA) into deep cavities and light curing them might increase pulpal temperature and threaten its health. The purpose of this study was to evaluate temperature rise of pulp by light curing six BA using two different light curing units (LCU), through a dent in wall of 0.5 mm. MATERIALS AND METHODS: This in vitro experiment was carried out on 96 slices of the same number of human third molars (6 BAs × 2 LCUs × 8 specimens in each group). There were 6 groups of BAs: N Bond, G-Bond, OptiBond XTR, Clearfil SE, Adper Single Bond 2 and V Bond. Each group of BA (n = 16) had two subgroups of light emitting diode (LED) and quartz-tungsten-halogen light cure units (n = 8). Each of these 16 specimens were subjected to light emitting for 20 s, once without any BAs (control) and later when a BA was applied to surface of disk. Temperature rises in 140 s were evaluated. Their mean temperature change in first 20 s were calculated and analyzed using two-way repeated-measures and one-way analysis of variance (ANOVA) and Tukey (α = 0.05). Furthermore rate of temperature increase was calculated for each material and LCU. RESULTS: Minimum and maximum temperature rises in all subgroups were 1.7 and 2.8°C, respectively. Repeated measures ANOVA showed that both of adhesive and LCU types had significant effect on temperature rise after application of adhesives. Tukey post-hoc analysis showed Clearfil SE showed significantly higher temperature rise in comparison with Adper Single bond 2 (P = 0.047) and N Bond (P = 0.038). Temperature rose in a linear fashion during first 30-40 s and after that it was non-linear. CONCLUSION: 20 s of light curing seems safe for pulpal health (with critical threshold of 5.5°C). However, in longer durations and especially when using LED units, the process should be broken to two sessions. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4387631/ /pubmed/25878684 Text en Copyright: © Dental Research Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Khaksaran, Najmeh Khatoon
Kashi, Tahereh Jafarzadeh
Rakhshan, Vahid
Zeynolabedin, Zahra Sadat
Bagheri, Hossein
Kinetics of pulpal temperature rise during light curing of 6 bonding agents from different generations, using light emitting diode and quartz-tungsten-halogen units: An in-vitro simulation
title Kinetics of pulpal temperature rise during light curing of 6 bonding agents from different generations, using light emitting diode and quartz-tungsten-halogen units: An in-vitro simulation
title_full Kinetics of pulpal temperature rise during light curing of 6 bonding agents from different generations, using light emitting diode and quartz-tungsten-halogen units: An in-vitro simulation
title_fullStr Kinetics of pulpal temperature rise during light curing of 6 bonding agents from different generations, using light emitting diode and quartz-tungsten-halogen units: An in-vitro simulation
title_full_unstemmed Kinetics of pulpal temperature rise during light curing of 6 bonding agents from different generations, using light emitting diode and quartz-tungsten-halogen units: An in-vitro simulation
title_short Kinetics of pulpal temperature rise during light curing of 6 bonding agents from different generations, using light emitting diode and quartz-tungsten-halogen units: An in-vitro simulation
title_sort kinetics of pulpal temperature rise during light curing of 6 bonding agents from different generations, using light emitting diode and quartz-tungsten-halogen units: an in-vitro simulation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4387631/
https://www.ncbi.nlm.nih.gov/pubmed/25878684
work_keys_str_mv AT khaksarannajmehkhatoon kineticsofpulpaltemperatureriseduringlightcuringof6bondingagentsfromdifferentgenerationsusinglightemittingdiodeandquartztungstenhalogenunitsaninvitrosimulation
AT kashitaherehjafarzadeh kineticsofpulpaltemperatureriseduringlightcuringof6bondingagentsfromdifferentgenerationsusinglightemittingdiodeandquartztungstenhalogenunitsaninvitrosimulation
AT rakhshanvahid kineticsofpulpaltemperatureriseduringlightcuringof6bondingagentsfromdifferentgenerationsusinglightemittingdiodeandquartztungstenhalogenunitsaninvitrosimulation
AT zeynolabedinzahrasadat kineticsofpulpaltemperatureriseduringlightcuringof6bondingagentsfromdifferentgenerationsusinglightemittingdiodeandquartztungstenhalogenunitsaninvitrosimulation
AT bagherihossein kineticsofpulpaltemperatureriseduringlightcuringof6bondingagentsfromdifferentgenerationsusinglightemittingdiodeandquartztungstenhalogenunitsaninvitrosimulation