Cargando…
Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU
INTRODUCTION: Measurement of static pupillary size in the ICU is of importance in cases of acutely expanding intracranial mass lesions. The inaccuracies with subjective assessment of pupillary size by medical personnel preclude its use in emergent neurological situations. OBJECTIVE: To determine if...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4387813/ https://www.ncbi.nlm.nih.gov/pubmed/25883482 http://dx.doi.org/10.4103/0976-3147.153229 |
_version_ | 1782365329605787648 |
---|---|
author | Mojumder, Deb Kumar Patel, Saumil Nugent, Kenneth Detoledo, John Kim, Jongyeol Dar, Nabeel Wilms, Henrik |
author_facet | Mojumder, Deb Kumar Patel, Saumil Nugent, Kenneth Detoledo, John Kim, Jongyeol Dar, Nabeel Wilms, Henrik |
author_sort | Mojumder, Deb Kumar |
collection | PubMed |
description | INTRODUCTION: Measurement of static pupillary size in the ICU is of importance in cases of acutely expanding intracranial mass lesions. The inaccuracies with subjective assessment of pupillary size by medical personnel preclude its use in emergent neurological situations. OBJECTIVE: To determine if the ratio of pupil to limbus diameter (PLD ratio) measured by a two-box method is a reliable measure of pupil size for detecting early anisocoria and measuring pupillary changes. MATERIALS AND METHODS: The PLD ratio was defined as the ratio of the pupillary diameter measured at a para-horizontal axial plane with the limbus diameter measured at the same or parallel axial plane. A two-box method was used to estimate the diameters of imaged pupils. Eyes were imaged using an iPhone 4S cellphone camera. Background illumination was measured and kept constant. The pupils of a 78-year-old woman, who presented with a large intra-axial parenchymal hemorrhage, were imaged. The patient had left pupillary miosis in dark but not in bright light. After presenting this case along with the images of the pupillary examination, a group of 21 medical staff were asked several questions on the pupillary examination. Reliability of PLD ratio were assessed via standard error of mean (S.E.M) of PLD ratios for 3 different subjects each imaged under constant illumination and fixation but from different angles to the optical axis. RESULTS: Analysis of questionnaire data together with PLD ratios revealed that ~ 14% and 10% of participants could estimate the pupillary size in darkness and bright light respectively but none were simultaneously accurate indicating that subjective assessment of pupillary size was unreliable. The approach towards a systematic pupillary examination was inconsistent among the participants. The PLD ratio was found to be a reliable measure of pupillary size with standard error of mean below 0.1 mm for the three subjects tested. CONCLUSION: Static pupillary sizes can be objectively and consistently evaluated using PLD ratios using a two-box method. PLD ratios are resistant, within limits, to changes in imaging angle or choice of para-horizontal axes for measurement. |
format | Online Article Text |
id | pubmed-4387813 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-43878132015-04-16 Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU Mojumder, Deb Kumar Patel, Saumil Nugent, Kenneth Detoledo, John Kim, Jongyeol Dar, Nabeel Wilms, Henrik J Neurosci Rural Pract Original Article INTRODUCTION: Measurement of static pupillary size in the ICU is of importance in cases of acutely expanding intracranial mass lesions. The inaccuracies with subjective assessment of pupillary size by medical personnel preclude its use in emergent neurological situations. OBJECTIVE: To determine if the ratio of pupil to limbus diameter (PLD ratio) measured by a two-box method is a reliable measure of pupil size for detecting early anisocoria and measuring pupillary changes. MATERIALS AND METHODS: The PLD ratio was defined as the ratio of the pupillary diameter measured at a para-horizontal axial plane with the limbus diameter measured at the same or parallel axial plane. A two-box method was used to estimate the diameters of imaged pupils. Eyes were imaged using an iPhone 4S cellphone camera. Background illumination was measured and kept constant. The pupils of a 78-year-old woman, who presented with a large intra-axial parenchymal hemorrhage, were imaged. The patient had left pupillary miosis in dark but not in bright light. After presenting this case along with the images of the pupillary examination, a group of 21 medical staff were asked several questions on the pupillary examination. Reliability of PLD ratio were assessed via standard error of mean (S.E.M) of PLD ratios for 3 different subjects each imaged under constant illumination and fixation but from different angles to the optical axis. RESULTS: Analysis of questionnaire data together with PLD ratios revealed that ~ 14% and 10% of participants could estimate the pupillary size in darkness and bright light respectively but none were simultaneously accurate indicating that subjective assessment of pupillary size was unreliable. The approach towards a systematic pupillary examination was inconsistent among the participants. The PLD ratio was found to be a reliable measure of pupillary size with standard error of mean below 0.1 mm for the three subjects tested. CONCLUSION: Static pupillary sizes can be objectively and consistently evaluated using PLD ratios using a two-box method. PLD ratios are resistant, within limits, to changes in imaging angle or choice of para-horizontal axes for measurement. Medknow Publications & Media Pvt Ltd 2015 /pmc/articles/PMC4387813/ /pubmed/25883482 http://dx.doi.org/10.4103/0976-3147.153229 Text en Copyright: © Journal of Neurosciences in Rural Practice http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Mojumder, Deb Kumar Patel, Saumil Nugent, Kenneth Detoledo, John Kim, Jongyeol Dar, Nabeel Wilms, Henrik Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU |
title | Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU |
title_full | Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU |
title_fullStr | Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU |
title_full_unstemmed | Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU |
title_short | Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU |
title_sort | pupil to limbus ratio: introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the icu |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4387813/ https://www.ncbi.nlm.nih.gov/pubmed/25883482 http://dx.doi.org/10.4103/0976-3147.153229 |
work_keys_str_mv | AT mojumderdebkumar pupiltolimbusratiointroducingasimpleobjectivemeasureusingtwoboxmethodformeasuringearlyanisocoriaandprogressofpupillarychangeintheicu AT patelsaumil pupiltolimbusratiointroducingasimpleobjectivemeasureusingtwoboxmethodformeasuringearlyanisocoriaandprogressofpupillarychangeintheicu AT nugentkenneth pupiltolimbusratiointroducingasimpleobjectivemeasureusingtwoboxmethodformeasuringearlyanisocoriaandprogressofpupillarychangeintheicu AT detoledojohn pupiltolimbusratiointroducingasimpleobjectivemeasureusingtwoboxmethodformeasuringearlyanisocoriaandprogressofpupillarychangeintheicu AT kimjongyeol pupiltolimbusratiointroducingasimpleobjectivemeasureusingtwoboxmethodformeasuringearlyanisocoriaandprogressofpupillarychangeintheicu AT darnabeel pupiltolimbusratiointroducingasimpleobjectivemeasureusingtwoboxmethodformeasuringearlyanisocoriaandprogressofpupillarychangeintheicu AT wilmshenrik pupiltolimbusratiointroducingasimpleobjectivemeasureusingtwoboxmethodformeasuringearlyanisocoriaandprogressofpupillarychangeintheicu |