Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material
Retropatellar complications after total knee arthroplasty (TKA) such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral jo...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4388012/ https://www.ncbi.nlm.nih.gov/pubmed/25879019 http://dx.doi.org/10.1155/2015/185142 |
_version_ | 1782365365412560896 |
---|---|
author | Schröder, Christian Steinbrück, Arnd Müller, Tatjana Woiczinski, Matthias Chevalier, Yan Weber, Patrick Müller, Peter E. Jansson, Volkmar |
author_facet | Schröder, Christian Steinbrück, Arnd Müller, Tatjana Woiczinski, Matthias Chevalier, Yan Weber, Patrick Müller, Peter E. Jansson, Volkmar |
author_sort | Schröder, Christian |
collection | PubMed |
description | Retropatellar complications after total knee arthroplasty (TKA) such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral joint modifications separately with 3D-rapid prototyped components for in vitro tests, but material differences may further influence results. This pilot study aims at validating the use of prostheses made of photopolymerized rapid prototype material (RPM) by measuring the sliding friction with a ring-on-disc setup as well as knee kinematics and retropatellar pressure on a knee rig. Cobalt-chromium alloy (standard prosthesis material, SPM) prostheses served as validation standard. Friction coefficients between these materials and polytetrafluoroethylene (PTFE) were additionally tested as this latter material is commonly used to protect pressure sensors in experiments. No statistical differences were found between friction coefficients of both materials to PTFE. UHMWPE shows higher friction coefficient at low axial loads for RPM, a difference that disappears at higher load. No measurable statistical differences were found in knee kinematics and retropatellar pressure distribution. This suggests that using polymer prototypes may be a valid alternative to original components for in vitro TKA studies and future investigations on knee biomechanics. |
format | Online Article Text |
id | pubmed-4388012 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-43880122015-04-15 Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material Schröder, Christian Steinbrück, Arnd Müller, Tatjana Woiczinski, Matthias Chevalier, Yan Weber, Patrick Müller, Peter E. Jansson, Volkmar Biomed Res Int Research Article Retropatellar complications after total knee arthroplasty (TKA) such as anterior knee pain and subluxations might be related to altered patellofemoral biomechanics, in particular to trochlear design and femorotibial joint positioning. A method was developed to test femorotibial and patellofemoral joint modifications separately with 3D-rapid prototyped components for in vitro tests, but material differences may further influence results. This pilot study aims at validating the use of prostheses made of photopolymerized rapid prototype material (RPM) by measuring the sliding friction with a ring-on-disc setup as well as knee kinematics and retropatellar pressure on a knee rig. Cobalt-chromium alloy (standard prosthesis material, SPM) prostheses served as validation standard. Friction coefficients between these materials and polytetrafluoroethylene (PTFE) were additionally tested as this latter material is commonly used to protect pressure sensors in experiments. No statistical differences were found between friction coefficients of both materials to PTFE. UHMWPE shows higher friction coefficient at low axial loads for RPM, a difference that disappears at higher load. No measurable statistical differences were found in knee kinematics and retropatellar pressure distribution. This suggests that using polymer prototypes may be a valid alternative to original components for in vitro TKA studies and future investigations on knee biomechanics. Hindawi Publishing Corporation 2015 2015-03-24 /pmc/articles/PMC4388012/ /pubmed/25879019 http://dx.doi.org/10.1155/2015/185142 Text en Copyright © 2015 Christian Schröder et al. https://creativecommons.org/licenses/by/3.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Schröder, Christian Steinbrück, Arnd Müller, Tatjana Woiczinski, Matthias Chevalier, Yan Weber, Patrick Müller, Peter E. Jansson, Volkmar Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material |
title | Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material |
title_full | Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material |
title_fullStr | Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material |
title_full_unstemmed | Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material |
title_short | Rapid Prototyping for In Vitro Knee Rig Investigations of Prosthetized Knee Biomechanics: Comparison with Cobalt-Chromium Alloy Implant Material |
title_sort | rapid prototyping for in vitro knee rig investigations of prosthetized knee biomechanics: comparison with cobalt-chromium alloy implant material |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4388012/ https://www.ncbi.nlm.nih.gov/pubmed/25879019 http://dx.doi.org/10.1155/2015/185142 |
work_keys_str_mv | AT schroderchristian rapidprototypingforinvitrokneeriginvestigationsofprosthetizedkneebiomechanicscomparisonwithcobaltchromiumalloyimplantmaterial AT steinbruckarnd rapidprototypingforinvitrokneeriginvestigationsofprosthetizedkneebiomechanicscomparisonwithcobaltchromiumalloyimplantmaterial AT mullertatjana rapidprototypingforinvitrokneeriginvestigationsofprosthetizedkneebiomechanicscomparisonwithcobaltchromiumalloyimplantmaterial AT woiczinskimatthias rapidprototypingforinvitrokneeriginvestigationsofprosthetizedkneebiomechanicscomparisonwithcobaltchromiumalloyimplantmaterial AT chevalieryan rapidprototypingforinvitrokneeriginvestigationsofprosthetizedkneebiomechanicscomparisonwithcobaltchromiumalloyimplantmaterial AT weberpatrick rapidprototypingforinvitrokneeriginvestigationsofprosthetizedkneebiomechanicscomparisonwithcobaltchromiumalloyimplantmaterial AT mullerpetere rapidprototypingforinvitrokneeriginvestigationsofprosthetizedkneebiomechanicscomparisonwithcobaltchromiumalloyimplantmaterial AT janssonvolkmar rapidprototypingforinvitrokneeriginvestigationsofprosthetizedkneebiomechanicscomparisonwithcobaltchromiumalloyimplantmaterial |