Cargando…

The Quality of Sputum Smear Microscopy in Public-Private Mix Directly Observed Treatment Laboratories in West Amhara Region, Ethiopia

Ethiopia adopted Public-Private Mix Directly Observed Treatment Short Course Chemotherapy (PPM-DOTS) strategy for tuberculosis (TB) control program. Quality of sputum smear microscopy has paramount importance for tuberculosis control program in resource-poor countries like Ethiopia. A cross-sectiona...

Descripción completa

Detalles Bibliográficos
Autores principales: Manalebh, Almaw, Demissie, Meaza, Mekonnen, Daniel, Abera, Bayeh
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2015
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4388465/
https://www.ncbi.nlm.nih.gov/pubmed/25849516
http://dx.doi.org/10.1371/journal.pone.0123749
_version_ 1782365385838821376
author Manalebh, Almaw
Demissie, Meaza
Mekonnen, Daniel
Abera, Bayeh
author_facet Manalebh, Almaw
Demissie, Meaza
Mekonnen, Daniel
Abera, Bayeh
author_sort Manalebh, Almaw
collection PubMed
description Ethiopia adopted Public-Private Mix Directly Observed Treatment Short Course Chemotherapy (PPM-DOTS) strategy for tuberculosis (TB) control program. Quality of sputum smear microscopy has paramount importance for tuberculosis control program in resource-poor countries like Ethiopia. A cross-sectional study was conducted to assess the quality of sputum smear microscopy in 37 Public-Private Mix laboratories in West Amhara, Ethiopia. The three external quality assessment methods (onsite evaluation, panel testing and blind rechecking) were employed. Onsite assessment revealed that 67.6% of PPM-DOTS laboratories were below the standard physical space (5 X 6) m(2). The average monthly workload per laboratory technician was 19.5 (SD±2.9) slides with 12.8% positivity rate. The quality of Acid Fast Bacilli (AFB) staining reagents was sub-standard. The overall agreement for blind rechecking of 1,123 AFB slides was 99.4% (Kappa = 0.97). Reading of 370 AFB panel slides showed 3.5% false reading (Kappa = 0.92). Moreover, the consistency of reading scanty bacilli slides was lower (93%) compared to 1+, 2+ and 3+ bacilli. Based on blind rechecking and panel testing results, PPM-DOTS site laboratories showed good agreement with the reference laboratory. Physical space and qualities of AFB reagents would be areas of intervention to sustain the quality of sputum smear microscopy. Therefore, regular external quality assessment and provision of basic laboratory supplies for TB diagnosis would be the way forward to improve the quality of sputum smear microscopy services in PPM-DOTS laboratories.
format Online
Article
Text
id pubmed-4388465
institution National Center for Biotechnology Information
language English
publishDate 2015
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-43884652015-04-21 The Quality of Sputum Smear Microscopy in Public-Private Mix Directly Observed Treatment Laboratories in West Amhara Region, Ethiopia Manalebh, Almaw Demissie, Meaza Mekonnen, Daniel Abera, Bayeh PLoS One Research Article Ethiopia adopted Public-Private Mix Directly Observed Treatment Short Course Chemotherapy (PPM-DOTS) strategy for tuberculosis (TB) control program. Quality of sputum smear microscopy has paramount importance for tuberculosis control program in resource-poor countries like Ethiopia. A cross-sectional study was conducted to assess the quality of sputum smear microscopy in 37 Public-Private Mix laboratories in West Amhara, Ethiopia. The three external quality assessment methods (onsite evaluation, panel testing and blind rechecking) were employed. Onsite assessment revealed that 67.6% of PPM-DOTS laboratories were below the standard physical space (5 X 6) m(2). The average monthly workload per laboratory technician was 19.5 (SD±2.9) slides with 12.8% positivity rate. The quality of Acid Fast Bacilli (AFB) staining reagents was sub-standard. The overall agreement for blind rechecking of 1,123 AFB slides was 99.4% (Kappa = 0.97). Reading of 370 AFB panel slides showed 3.5% false reading (Kappa = 0.92). Moreover, the consistency of reading scanty bacilli slides was lower (93%) compared to 1+, 2+ and 3+ bacilli. Based on blind rechecking and panel testing results, PPM-DOTS site laboratories showed good agreement with the reference laboratory. Physical space and qualities of AFB reagents would be areas of intervention to sustain the quality of sputum smear microscopy. Therefore, regular external quality assessment and provision of basic laboratory supplies for TB diagnosis would be the way forward to improve the quality of sputum smear microscopy services in PPM-DOTS laboratories. Public Library of Science 2015-04-07 /pmc/articles/PMC4388465/ /pubmed/25849516 http://dx.doi.org/10.1371/journal.pone.0123749 Text en © 2015 Manalebh et al http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.
spellingShingle Research Article
Manalebh, Almaw
Demissie, Meaza
Mekonnen, Daniel
Abera, Bayeh
The Quality of Sputum Smear Microscopy in Public-Private Mix Directly Observed Treatment Laboratories in West Amhara Region, Ethiopia
title The Quality of Sputum Smear Microscopy in Public-Private Mix Directly Observed Treatment Laboratories in West Amhara Region, Ethiopia
title_full The Quality of Sputum Smear Microscopy in Public-Private Mix Directly Observed Treatment Laboratories in West Amhara Region, Ethiopia
title_fullStr The Quality of Sputum Smear Microscopy in Public-Private Mix Directly Observed Treatment Laboratories in West Amhara Region, Ethiopia
title_full_unstemmed The Quality of Sputum Smear Microscopy in Public-Private Mix Directly Observed Treatment Laboratories in West Amhara Region, Ethiopia
title_short The Quality of Sputum Smear Microscopy in Public-Private Mix Directly Observed Treatment Laboratories in West Amhara Region, Ethiopia
title_sort quality of sputum smear microscopy in public-private mix directly observed treatment laboratories in west amhara region, ethiopia
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4388465/
https://www.ncbi.nlm.nih.gov/pubmed/25849516
http://dx.doi.org/10.1371/journal.pone.0123749
work_keys_str_mv AT manalebhalmaw thequalityofsputumsmearmicroscopyinpublicprivatemixdirectlyobservedtreatmentlaboratoriesinwestamhararegionethiopia
AT demissiemeaza thequalityofsputumsmearmicroscopyinpublicprivatemixdirectlyobservedtreatmentlaboratoriesinwestamhararegionethiopia
AT mekonnendaniel thequalityofsputumsmearmicroscopyinpublicprivatemixdirectlyobservedtreatmentlaboratoriesinwestamhararegionethiopia
AT aberabayeh thequalityofsputumsmearmicroscopyinpublicprivatemixdirectlyobservedtreatmentlaboratoriesinwestamhararegionethiopia
AT manalebhalmaw qualityofsputumsmearmicroscopyinpublicprivatemixdirectlyobservedtreatmentlaboratoriesinwestamhararegionethiopia
AT demissiemeaza qualityofsputumsmearmicroscopyinpublicprivatemixdirectlyobservedtreatmentlaboratoriesinwestamhararegionethiopia
AT mekonnendaniel qualityofsputumsmearmicroscopyinpublicprivatemixdirectlyobservedtreatmentlaboratoriesinwestamhararegionethiopia
AT aberabayeh qualityofsputumsmearmicroscopyinpublicprivatemixdirectlyobservedtreatmentlaboratoriesinwestamhararegionethiopia