Cargando…
Sensitivity of Susceptibility-Weighted Imaging in Detecting Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells: A Comparative Study
BACKGROUND: Susceptibility-weighted imaging (SWI) is extremely sensitive in the detection of superparamagnetic iron oxide (SPIO) nanoparticle-labeled cells. However, no study has compared molecular imaging for stem cell detection using SWI and other MRI pulse sequences. OBJECTIVES: This study aims t...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Kowsar
2015
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4389178/ https://www.ncbi.nlm.nih.gov/pubmed/25901258 http://dx.doi.org/10.5812/iranjradiol.20782 |
_version_ | 1782365506148237312 |
---|---|
author | Park, Serah Kwak, Byung Kook Jung, Jisung |
author_facet | Park, Serah Kwak, Byung Kook Jung, Jisung |
author_sort | Park, Serah |
collection | PubMed |
description | BACKGROUND: Susceptibility-weighted imaging (SWI) is extremely sensitive in the detection of superparamagnetic iron oxide (SPIO) nanoparticle-labeled cells. However, no study has compared molecular imaging for stem cell detection using SWI and other MRI pulse sequences. OBJECTIVES: This study aims to assess the sensitivity of SWI in detecting SPIO nanoparticle-labeled, human bone marrow-derived mesenchymal stem cells (SPIO-hMSCs) compared with that of T(2)- and T(2)*-weighted imaging (T(2)WI and T(2)*WI, respectively) in a phantom and in vivo study in rats. MATERIALS AND METHODS: A phantom was prepared with various cell concentrations. In one normal rat, SPIO-hMSCs were implanted directly through burr holes into both caudate putamens, while in three rats without and six rats with photothrombotic infarction, 2.5 × 10(5)/ml SPIO-hMSCs were infused into the ipsilateral internal carotid artery (ICA). T(2)WI, T(2)*WI, and SWI findings were compared for dark regions representing SPIO-hMSCs. RESULTS: SWI and T(2)*WI detected 15 µL of 13 SPIO-hMSCs/µL and 15 µL of 27 SPIO-hMSCs/µL in the phantom, respectively and 3 µL of 333 SPIO-hMSCs/µL and 3 µL of 167 SPIO-hMSCs/µL in the normal rat brain (direct implantation). In the normal rat brain (ICA infusion), one of the three cases showed numerous foci of dark regions dispersed throughout the brain on T(2)*WI and SWI. Dark regions surrounded the infarcts in all six infracted rat brains. The dark region was most prominent on SWI, followed by T(2)*WI and T(2)WI in all six rats (P = 0.002). Implanted SPIO-hMSCs were confirmed using Prussian blue staining. CONCLUSIONS: SWI is the most sensitive in the detection of SPIO-hMSCs, with the dark regions representing SPIO-hMSCs being more prominent on SWI than on T(2)*WI and T(2)WI. |
format | Online Article Text |
id | pubmed-4389178 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2015 |
publisher | Kowsar |
record_format | MEDLINE/PubMed |
spelling | pubmed-43891782015-04-22 Sensitivity of Susceptibility-Weighted Imaging in Detecting Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells: A Comparative Study Park, Serah Kwak, Byung Kook Jung, Jisung Iran J Radiol Physics BACKGROUND: Susceptibility-weighted imaging (SWI) is extremely sensitive in the detection of superparamagnetic iron oxide (SPIO) nanoparticle-labeled cells. However, no study has compared molecular imaging for stem cell detection using SWI and other MRI pulse sequences. OBJECTIVES: This study aims to assess the sensitivity of SWI in detecting SPIO nanoparticle-labeled, human bone marrow-derived mesenchymal stem cells (SPIO-hMSCs) compared with that of T(2)- and T(2)*-weighted imaging (T(2)WI and T(2)*WI, respectively) in a phantom and in vivo study in rats. MATERIALS AND METHODS: A phantom was prepared with various cell concentrations. In one normal rat, SPIO-hMSCs were implanted directly through burr holes into both caudate putamens, while in three rats without and six rats with photothrombotic infarction, 2.5 × 10(5)/ml SPIO-hMSCs were infused into the ipsilateral internal carotid artery (ICA). T(2)WI, T(2)*WI, and SWI findings were compared for dark regions representing SPIO-hMSCs. RESULTS: SWI and T(2)*WI detected 15 µL of 13 SPIO-hMSCs/µL and 15 µL of 27 SPIO-hMSCs/µL in the phantom, respectively and 3 µL of 333 SPIO-hMSCs/µL and 3 µL of 167 SPIO-hMSCs/µL in the normal rat brain (direct implantation). In the normal rat brain (ICA infusion), one of the three cases showed numerous foci of dark regions dispersed throughout the brain on T(2)*WI and SWI. Dark regions surrounded the infarcts in all six infracted rat brains. The dark region was most prominent on SWI, followed by T(2)*WI and T(2)WI in all six rats (P = 0.002). Implanted SPIO-hMSCs were confirmed using Prussian blue staining. CONCLUSIONS: SWI is the most sensitive in the detection of SPIO-hMSCs, with the dark regions representing SPIO-hMSCs being more prominent on SWI than on T(2)*WI and T(2)WI. Kowsar 2015-04-22 /pmc/articles/PMC4389178/ /pubmed/25901258 http://dx.doi.org/10.5812/iranjradiol.20782 Text en Copyright © 2015, Tehran University of Medical Sciences and Iranian Society of Radiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/) which permits copy and redistribute the material just in noncommercial usages, provided the original work is properly cited. |
spellingShingle | Physics Park, Serah Kwak, Byung Kook Jung, Jisung Sensitivity of Susceptibility-Weighted Imaging in Detecting Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells: A Comparative Study |
title | Sensitivity of Susceptibility-Weighted Imaging in Detecting Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells: A Comparative Study |
title_full | Sensitivity of Susceptibility-Weighted Imaging in Detecting Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells: A Comparative Study |
title_fullStr | Sensitivity of Susceptibility-Weighted Imaging in Detecting Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells: A Comparative Study |
title_full_unstemmed | Sensitivity of Susceptibility-Weighted Imaging in Detecting Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells: A Comparative Study |
title_short | Sensitivity of Susceptibility-Weighted Imaging in Detecting Superparamagnetic Iron Oxide-Labeled Mesenchymal Stem Cells: A Comparative Study |
title_sort | sensitivity of susceptibility-weighted imaging in detecting superparamagnetic iron oxide-labeled mesenchymal stem cells: a comparative study |
topic | Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4389178/ https://www.ncbi.nlm.nih.gov/pubmed/25901258 http://dx.doi.org/10.5812/iranjradiol.20782 |
work_keys_str_mv | AT parkserah sensitivityofsusceptibilityweightedimagingindetectingsuperparamagneticironoxidelabeledmesenchymalstemcellsacomparativestudy AT kwakbyungkook sensitivityofsusceptibilityweightedimagingindetectingsuperparamagneticironoxidelabeledmesenchymalstemcellsacomparativestudy AT jungjisung sensitivityofsusceptibilityweightedimagingindetectingsuperparamagneticironoxidelabeledmesenchymalstemcellsacomparativestudy |