Cargando…
Proposal of renal artery's ostial projection under virtual geometric correction in infrarenal aneurysms: initial results of a pilot study
INTRODUCTION: Endovascular aneurysm repair requires the precise deployment of the graft. In order to achieve accurate positioning, the anatomical and morphological characteristics of the aorta and its branches is mandatory. Software that perform three dimensional reformatting of multislice tomograph...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Sociedade Brasileira de Cirurgia Cardiovascular
2014
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4389474/ https://www.ncbi.nlm.nih.gov/pubmed/24896166 http://dx.doi.org/10.5935/1678-9741.20140014 |
_version_ | 1782365570326331392 |
---|---|
author | Molinari, Giovani José Dal Poggetto Dalbem, Andreia Marques de Oliveira Menezes, Fabio Hüsemann Guillaumon, Ana Terezinha |
author_facet | Molinari, Giovani José Dal Poggetto Dalbem, Andreia Marques de Oliveira Menezes, Fabio Hüsemann Guillaumon, Ana Terezinha |
author_sort | Molinari, Giovani José Dal Poggetto |
collection | PubMed |
description | INTRODUCTION: Endovascular aneurysm repair requires the precise deployment of the graft. In order to achieve accurate positioning, the anatomical and morphological characteristics of the aorta and its branches is mandatory. Software that perform three dimensional reformatting of multislice tomographic images, allow for the study of the whole aorto-iliac axis and the perpendicular visualization of the origin of the renal arteries. The correct length of the proximal neck can be evaluated and adequate graft fixation and sealing may be foreseen. A technique is presented, using an software, for the orthogonal correction of the position of the renal arteries in relation to the proximal neck, which may guide the radioscopic orientation intraoperatively. METHODS: Within a multiplanar tomographic image reconstruction, virtual triangulation allows for the three dimensional orthogonal correction of the renal arteries' ostia position. The predetermined best angulations for visualization are annotated and used for the positioning of the surgical C-arm. RESULTS/DISCUSSION: Some authors discuss that the anatomic position of the renal vessels seen on the tomographic scan can change during the surgical procedure. It is known that the renal arterys' angular positioning does not alter, even after insertion of stiff guidewires, introducers, and the endograft itself. Therefore, it is possible, using concepts of spacial geometry and orthogonal correction, to predict the ideal bidimensional intraoperative positioning of the radioscopy device in order to reproduce the optimized renal artery ostial projection, ensuring the best accuracy during endograft deployment. CONCLUSION: As closer to the tomographic reproduction was the radioscopic correction, more careful is the visualization of the ostium of the renal artery, better is the exploitation of the lap for fixing and sealing and the endoprosthesis deployment is more accurate. |
format | Online Article Text |
id | pubmed-4389474 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2014 |
publisher | Sociedade Brasileira de Cirurgia Cardiovascular |
record_format | MEDLINE/PubMed |
spelling | pubmed-43894742015-04-14 Proposal of renal artery's ostial projection under virtual geometric correction in infrarenal aneurysms: initial results of a pilot study Molinari, Giovani José Dal Poggetto Dalbem, Andreia Marques de Oliveira Menezes, Fabio Hüsemann Guillaumon, Ana Terezinha Rev Bras Cir Cardiovasc Special Articles INTRODUCTION: Endovascular aneurysm repair requires the precise deployment of the graft. In order to achieve accurate positioning, the anatomical and morphological characteristics of the aorta and its branches is mandatory. Software that perform three dimensional reformatting of multislice tomographic images, allow for the study of the whole aorto-iliac axis and the perpendicular visualization of the origin of the renal arteries. The correct length of the proximal neck can be evaluated and adequate graft fixation and sealing may be foreseen. A technique is presented, using an software, for the orthogonal correction of the position of the renal arteries in relation to the proximal neck, which may guide the radioscopic orientation intraoperatively. METHODS: Within a multiplanar tomographic image reconstruction, virtual triangulation allows for the three dimensional orthogonal correction of the renal arteries' ostia position. The predetermined best angulations for visualization are annotated and used for the positioning of the surgical C-arm. RESULTS/DISCUSSION: Some authors discuss that the anatomic position of the renal vessels seen on the tomographic scan can change during the surgical procedure. It is known that the renal arterys' angular positioning does not alter, even after insertion of stiff guidewires, introducers, and the endograft itself. Therefore, it is possible, using concepts of spacial geometry and orthogonal correction, to predict the ideal bidimensional intraoperative positioning of the radioscopy device in order to reproduce the optimized renal artery ostial projection, ensuring the best accuracy during endograft deployment. CONCLUSION: As closer to the tomographic reproduction was the radioscopic correction, more careful is the visualization of the ostium of the renal artery, better is the exploitation of the lap for fixing and sealing and the endoprosthesis deployment is more accurate. Sociedade Brasileira de Cirurgia Cardiovascular 2014 /pmc/articles/PMC4389474/ /pubmed/24896166 http://dx.doi.org/10.5935/1678-9741.20140014 Text en http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Special Articles Molinari, Giovani José Dal Poggetto Dalbem, Andreia Marques de Oliveira Menezes, Fabio Hüsemann Guillaumon, Ana Terezinha Proposal of renal artery's ostial projection under virtual geometric correction in infrarenal aneurysms: initial results of a pilot study |
title | Proposal of renal artery's ostial projection under virtual geometric
correction in infrarenal aneurysms: initial results of a pilot study |
title_full | Proposal of renal artery's ostial projection under virtual geometric
correction in infrarenal aneurysms: initial results of a pilot study |
title_fullStr | Proposal of renal artery's ostial projection under virtual geometric
correction in infrarenal aneurysms: initial results of a pilot study |
title_full_unstemmed | Proposal of renal artery's ostial projection under virtual geometric
correction in infrarenal aneurysms: initial results of a pilot study |
title_short | Proposal of renal artery's ostial projection under virtual geometric
correction in infrarenal aneurysms: initial results of a pilot study |
title_sort | proposal of renal artery's ostial projection under virtual geometric
correction in infrarenal aneurysms: initial results of a pilot study |
topic | Special Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4389474/ https://www.ncbi.nlm.nih.gov/pubmed/24896166 http://dx.doi.org/10.5935/1678-9741.20140014 |
work_keys_str_mv | AT molinarigiovanijosedalpoggetto proposalofrenalarterysostialprojectionundervirtualgeometriccorrectionininfrarenalaneurysmsinitialresultsofapilotstudy AT dalbemandreiamarquesdeoliveira proposalofrenalarterysostialprojectionundervirtualgeometriccorrectionininfrarenalaneurysmsinitialresultsofapilotstudy AT menezesfabiohusemann proposalofrenalarterysostialprojectionundervirtualgeometriccorrectionininfrarenalaneurysmsinitialresultsofapilotstudy AT guillaumonanaterezinha proposalofrenalarterysostialprojectionundervirtualgeometriccorrectionininfrarenalaneurysmsinitialresultsofapilotstudy |